Inficon Modul 1000 Helium Leak Detector, 550300
Item#: PN07440 Mfr Part#: 550300 Manufacturer: Inficon
Condition: New
New Inficon Modul 1000 Helium Leak Detector, 550300

Features:
  • Maximum Detectable Leak Rate: < 5 x 10-12 mbar l/s
  • Maximum Inlet Pressure: .4 mbar
  • Helium Pumping Speed At Inlet: 2.5 l/s
  • Inlet Port / Fore-Vacuum Port: DN 25 KF

Price upon request
Item#: PN07440 Mfr Part#: 550300
Inficon Modul 1000 Helium Leak Detector, 550300
Item#: PN07440 Mfr Part#: 550300 Manufacturer: Inficon

Inficon Modul 1000 Helium Leak Detector, 550300

 

Inficon Modul 1000 Overview:


The Modul1000 is a plug-and-play helium leak detector for universal integration into industrial leak testing systems (vacuum or sniffer mode). With flexible vacuum architecture, the Modul1000 provides the adaptability to accommodate changes in production specifications.

The Modul1000 provides maximum measurement stability and ambient conditions isolation for repeatable measurement over long periods of time in changing conditions. The ion source filament is designed for long life.

The software algorithm I.CALTM provides accurate measurements at unsurpassed speed in all measurement ranges. This enables the Modul1000 to recognize and communicate the true leak rate faster. To facilitate unit exchange, user setups are stored in the removable I.Stick for easy, fast parameter transfer.

The Modul1000 offers flexible inputs and status outputs for PLC control. Additionally, control and data acquisition is available via the RS232 communication port. The optional display unit supplies easy operation through an intuitive menu structure and software menus.

Implemented software functions allow direct valve control of test systems without the need for an additional PLC.

 

Inficon Modul 1000 Features:


  • Compact design for easy integragion in benchtop or rack systems
  • Plug and play installation; flexible interfaces
  • Supports any size of foreline pump
  • Software algorithm I-CAL provides accurate test results in all measurement ranges
  • Wide range power supply
  • Integrated test leak
  • Flexible control via optional display unit, remote control, PLC or PC
  • Self-diagnostics capability
  • Low cost of ownership
  • Storage of parameter settings for easy data transfer on an integrated, removalbe I-STICK

 


Click Here for Inficon Modul 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Inficon Modul 1000 Helium Leak Detector, 550300

 

Inficon Modul 1000 Technical Data:


Maximum Detectable Leak Rate: < 5 x 10-12 mbar l/s
Maximum Inlet Pressure: .4 mbar
Helium Pumping Speed At Inlet: 2.5 l/s
Start-Up Time: < 3 minutes
Inlet Port / Fore-Vacuum Port: DN 25 KF
Power Supply: 85-265 V, 50/60 Hz

Click Here for Inficon Modul 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Inficon Modul 1000 Helium Leak Detector, 550300
Item#: PN07440 Mfr Part#: 550300 Manufacturer: Inficon

Inficon Modul 1000 Helium Leak Detector, 550300

 

Inficon Modul 1000 Overview:


The Modul1000 is a plug-and-play helium leak detector for universal integration into industrial leak testing systems (vacuum or sniffer mode). With flexible vacuum architecture, the Modul1000 provides the adaptability to accommodate changes in production specifications.

The Modul1000 provides maximum measurement stability and ambient conditions isolation for repeatable measurement over long periods of time in changing conditions. The ion source filament is designed for long life.

The software algorithm I.CALTM provides accurate measurements at unsurpassed speed in all measurement ranges. This enables the Modul1000 to recognize and communicate the true leak rate faster. To facilitate unit exchange, user setups are stored in the removable I.Stick for easy, fast parameter transfer.

The Modul1000 offers flexible inputs and status outputs for PLC control. Additionally, control and data acquisition is available via the RS232 communication port. The optional display unit supplies easy operation through an intuitive menu structure and software menus.

Implemented software functions allow direct valve control of test systems without the need for an additional PLC.

 

Inficon Modul 1000 Features:


  • Compact design for easy integragion in benchtop or rack systems
  • Plug and play installation; flexible interfaces
  • Supports any size of foreline pump
  • Software algorithm I-CAL provides accurate test results in all measurement ranges
  • Wide range power supply
  • Integrated test leak
  • Flexible control via optional display unit, remote control, PLC or PC
  • Self-diagnostics capability
  • Low cost of ownership
  • Storage of parameter settings for easy data transfer on an integrated, removalbe I-STICK

 


Click Here for Inficon Modul 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Inficon Modul 1000 Helium Leak Detector, 550300

 

Inficon Modul 1000 Technical Data:


Maximum Detectable Leak Rate: < 5 x 10-12 mbar l/s
Maximum Inlet Pressure: .4 mbar
Helium Pumping Speed At Inlet: 2.5 l/s
Start-Up Time: < 3 minutes
Inlet Port / Fore-Vacuum Port: DN 25 KF
Power Supply: 85-265 V, 50/60 Hz

Click Here for Inficon Modul 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.