Overview:
For maximum flexibility during your process, the RC1000 is available for wired or wireless operation. The RC1000WL wireless version allows remote operation up to 100 m, with an operating time of more than 8 hours. The RC1000C wired version enables remote operation up to 28 m from your leak detector.
Easy-to-use, the RC1000 can be programmed to display leak rates numerically or in chart or bar graph form on a 3.5“ touchscreen. The time axis on the screen can be scaled to display diagrams from 16 seconds up to 16 minutes.
Measured values are stored for up to 24 hours in an internal memory while the data recording interval is adjustable.
The data can be easily downloaded to a USB stick for PC readout or storage. An internal trigger can be set to provide a visual warning when exceeded, as well as an audible sound through the integrated loudspeaker or headphones. The sound’s tone is proportional to the measured leak rate (the higher the tone, the larger the leak rate).
The robust, ergonomically designed housing complies with IP42 protection class. Magnets on the bottom allow for horizontal or vertical attachment on metal ferromagnetic surfaces.
Features:
Technical Data:
Display: 3.5" TFT touch screen, full color, 240 x 320 px
Operating Range, Wireless: up to 100 m outdoor
Audio Alarm Internal Speaker: 70 dB(A) max.
Headphones: Stereo, 3.5 mm plug, > 30 Ohm impedance
Charging Voltage: 24 V DC
Data Storage Capacity: 32 MB
Operating Time, Wireless: > 8 hours by internal battery
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview:
For maximum flexibility during your process, the RC1000 is available for wired or wireless operation. The RC1000WL wireless version allows remote operation up to 100 m, with an operating time of more than 8 hours. The RC1000C wired version enables remote operation up to 28 m from your leak detector.
Easy-to-use, the RC1000 can be programmed to display leak rates numerically or in chart or bar graph form on a 3.5“ touchscreen. The time axis on the screen can be scaled to display diagrams from 16 seconds up to 16 minutes.
Measured values are stored for up to 24 hours in an internal memory while the data recording interval is adjustable.
The data can be easily downloaded to a USB stick for PC readout or storage. An internal trigger can be set to provide a visual warning when exceeded, as well as an audible sound through the integrated loudspeaker or headphones. The sound’s tone is proportional to the measured leak rate (the higher the tone, the larger the leak rate).
The robust, ergonomically designed housing complies with IP42 protection class. Magnets on the bottom allow for horizontal or vertical attachment on metal ferromagnetic surfaces.
Features:
Technical Data:
Display: 3.5" TFT touch screen, full color, 240 x 320 px
Operating Range, Wireless: up to 100 m outdoor
Audio Alarm Internal Speaker: 70 dB(A) max.
Headphones: Stereo, 3.5 mm plug, > 30 Ohm impedance
Charging Voltage: 24 V DC
Data Storage Capacity: 32 MB
Operating Time, Wireless: > 8 hours by internal battery
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.