Inficon UL 1000 Fab Helium Leak Detector, 115 VAC, Dry Scroll Pump, 550101A

Condition: New
Item#:PN00124
Mfr Part#:550101A / 550-101A
Manufacturer:Inficon
New Inficon UL 1000 Fab Helium Leak Detector, Dry Scroll Pump, 550101
Features:
  • Smallest Detectable Leak Rate: < 5 x 10-12 mbar l/s
  • Pumping Speed During Evacuation: 25 m3/h
  • Supply Voltages: 100-120 V; 220-240 V
  • Maximum Inlet Pressure: Gross: 15 mbar
12 months warranty

Inficon UL 1000 Fab Helium Leak Detector, Dry Scroll Pump, 550101, 550-101A

 

Inficon UL 1000  / 550-101A Overview:


The INFICON UL1000 Fab Mobile Helium Leak Detector is specially designed to meet the exacting requirements of the semiconductor industry: testing flexibility, high sensitivity, fast and accurate results, quick start-up, mobility and system reliability. The UL1000 Fab is optimized to provide quick leak testing results for preventive maintenance, unscheduled repair, gas lines, and other leak testing applications.

The UL1000 Fab meets the requirements of the micro-electronics market. Features range from its sturdy metal housing, with cleanroom compatible wheels, to I·CAL*, the unbeatable algorithm for eliminating long averaging times for leak rates in the ultrasensitive 10-11 and 10-12 leak rate ranges.

The system software includes advanced self-diagnosis routines with troubleshooting instructions. Protective functions can be called up to prevent contamination with helium or process gases. The ceiling-to-floor airflow commonly found in cleanrooms is not disturbed by the ventilation system of the UL1000 Fab. The pumping speed and compression of the turbomolecular pump reduce and rapidly eliminate helium contamination.

Using a special software algorithm called I·CAL, the UL1000 Fab provides measurements at unsurpassed speed in the 10-12 mbar l/s range, making that decade truly usable. While other leak detectors have to average the signals over minutes to achieve adequate stability, the UL1000 Fab with I·CAL responds with unparalleled speed and stability in this low measurement range.

For example, starting from a background reading of 1 x 10-12 mbar l/s, an ultra-tiny leak of 1 x 10-10 mbar l/s is displayed in less than a second.

The UL1000 Fab offers a rotatable control interface. The integrated display presents measurement results and status information in large characters with excellent clarity, so that readings can be observed conveniently from considerable distances.

The display mode can be selected as digital, bar graph, trend or circular. The most important basic functions (Start, Zero, Stop) are available at the press of a button. The software is menucontrolled and easy-to-use. Parts of the menu can be protected against unauthorized use or unintended modifications.

 

Inficon UL 1000, Helium Leak Detector, 550101

 


Click Here for Inficon UL 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Inficon UL 1000 Fab Helium Leak Detector, Dry Scroll Pump, 550101

 

Inficon UL 1000 Technical Data:


Smallest Detectable Leak Rate: < 5 x 10-12 mbar l/s
Maximum Inlet Pressure:

Gross: 15 mbar

 

Fine: 2 mbar

 

Ultra: .4 mbar

Helium Pumping Speed At Inlet:

Gross: 8 l/s

 

Fine: 7 l/s

 

Ultra: 2.5 l/s

Pumping Speed During Evacuation: 25 m3/h
Supply Voltages: 100-120 V; 220-240 V

Click Here for Inficon UL 1000 Manual

Click Here for Infocon Leak Detector Catalog

Click Here for Inficon Brochure


A&J Vacuum Services offers full repair/service of Inficon Modul 1000 Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Item#:PN17685
Mfr Part#:20028787
Condition: Out of Stock New
$395.00
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.