Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001
Item#: PN18598 Mfr Part#: 800072V0001 Manufacturer: Leybold
Condition:
Discontinued
Discontinued Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Features:
  • Power: 160 W

This product has been discontinued and is no longer available for sale
Item#: PN18598 Mfr Part#: 800072V0001
Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001
Item#: PN18598 Mfr Part#: 800072V0001 Manufacturer: Leybold 6 months warranty

This product is discontinued with no replacement.

 

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS


 

Turbo Drive TD 300 / 800072V0001 Overview:


The remanufactured TURBO.DRIVE 300 is suited for operation of the following pumps:

  • TURBOVAC TW 70 H
  • TURBOVAC TW 220/150 S, TW 220/150/15 S
  • TURBOVAC TW 250 S
  • TURBOVAC TW 290 H
  • TURBOVAC TW 300, TW 300 H

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS

 

Oerlikon / Leybold Turbo Drive TD 300 Technical Data:

  • Supply voltage: 24 V (21 ... 29 V)
  • Residual ripple: < 3 %
  • Voltage: 0 - 24 V 3~
  • Power: 160 W
  • Frequency: 0 - 1500 Hz
  • When operating a TW 300, TW 300 H, TW 220/150(/15) S:
    • Nominal voltage: 24 V
    • Max. power consumption: 190 W
    • Max. peak current, input side 8 A DC
    • Required power output from the power supply: ≥ 200 W
  • When operating a TW 70 H, TW 250 S:
    • Nominal voltage: 24 V
    • Max. power consumption: 140 W
    • Max. peak current, input side 6 A DC
    • Required power output from the power supply: ≥ 150 W
  • Max. length of the DC cable (shielded)
    • at 3 x 1.5 mm2 5 m
    • at 3 x 2.5 mm2 20 m
  • Relay output rating 42 V, 0.5 A
  • Ambient temperature during operation: 5 - 45 °C
  • storage - 15 - + 70 °C
  • Relative air humidity: 5 to 85 %
  • Non condensing
  • Overvoltage category II
  • Contamination grade 2
  • Temp. of the cooling surface: 5 - 55 °C
  • Power consumption: ≤ 20 W
  • Type of protection: IP20
  • Weight approx.: 0.7 kg | 1.54 lbs

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001
Item#: PN18598 Mfr Part#: 800072V0001 Manufacturer: Leybold

This product is discontinued with no replacement.

 

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS


 

Turbo Drive TD 300 / 800072V0001 Overview:


The remanufactured TURBO.DRIVE 300 is suited for operation of the following pumps:

  • TURBOVAC TW 70 H
  • TURBOVAC TW 220/150 S, TW 220/150/15 S
  • TURBOVAC TW 250 S
  • TURBOVAC TW 290 H
  • TURBOVAC TW 300, TW 300 H

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS

 

Oerlikon / Leybold Turbo Drive TD 300 Technical Data:

  • Supply voltage: 24 V (21 ... 29 V)
  • Residual ripple: < 3 %
  • Voltage: 0 - 24 V 3~
  • Power: 160 W
  • Frequency: 0 - 1500 Hz
  • When operating a TW 300, TW 300 H, TW 220/150(/15) S:
    • Nominal voltage: 24 V
    • Max. power consumption: 190 W
    • Max. peak current, input side 8 A DC
    • Required power output from the power supply: ≥ 200 W
  • When operating a TW 70 H, TW 250 S:
    • Nominal voltage: 24 V
    • Max. power consumption: 140 W
    • Max. peak current, input side 6 A DC
    • Required power output from the power supply: ≥ 150 W
  • Max. length of the DC cable (shielded)
    • at 3 x 1.5 mm2 5 m
    • at 3 x 2.5 mm2 20 m
  • Relay output rating 42 V, 0.5 A
  • Ambient temperature during operation: 5 - 45 °C
  • storage - 15 - + 70 °C
  • Relative air humidity: 5 to 85 %
  • Non condensing
  • Overvoltage category II
  • Contamination grade 2
  • Temp. of the cooling surface: 5 - 55 °C
  • Power consumption: ≤ 20 W
  • Type of protection: IP20
  • Weight approx.: 0.7 kg | 1.54 lbs

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.