Shopping Cart ( )

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Condition: Discontinued
Item#:PN18598
Mfr Part#:800072V0001
Manufacturer:Leybold
This product has been discontinued and is no longer available for sale
VIEW REPLACEMENT
Discontinued Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001
Features:
  • Power: 160 W
6 months warranty

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS

This product is discontinued with no replacement.


 

Oerlikon / Leybold Turbo Drive TD 300 Features:


The remanufactured TURBO.DRIVE 300 is suited for operation of the following pumps:

  • TURBOVAC TW 70 H
  • TURBOVAC TW 220/150 S, TW 220/150/15 S
  • TURBOVAC TW 250 S
  • TURBOVAC TW 290 H
  • TURBOVAC TW 300, TW 300 H

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Oerlikon / Leybold Turbo Drive TD 300 Turbo Pump Controller Frequency Converter for Turbomolecular Pumps, 800072V0001

Designed for PerkinElmer ELAN 9000 ICP-MS

 

Oerlikon / Leybold Turbo Drive TD 300 Technical Data:

  • Supply voltage: 24 V (21 ... 29 V)
  • Residual ripple: < 3 %
  • Voltage: 0 - 24 V 3~
  • Power: 160 W
  • Frequency: 0 - 1500 Hz
  • When operating a TW 300, TW 300 H, TW 220/150(/15) S:
    • Nominal voltage: 24 V
    • Max. power consumption: 190 W
    • Max. peak current, input side 8 A DC
    • Required power output from the power supply: ≥ 200 W
  • When operating a TW 70 H, TW 250 S:
    • Nominal voltage: 24 V
    • Max. power consumption: 140 W
    • Max. peak current, input side 6 A DC
    • Required power output from the power supply: ≥ 150 W
  • Max. length of the DC cable (shielded)
    • at 3 x 1.5 mm2 5 m
    • at 3 x 2.5 mm2 20 m
  • Relay output rating 42 V, 0.5 A
  • Ambient temperature during operation: 5 - 45 °C
  • storage - 15 - + 70 °C
  • Relative air humidity: 5 to 85 %
  • Non condensing
  • Overvoltage category II
  • Contamination grade 2
  • Temp. of the cooling surface: 5 - 55 °C
  • Power consumption: ≤ 20 W
  • Type of protection: IP20
  • Weight approx.: 0.7 kg | 1.54 lbs

 

A&J Vacuum services and repairs Leybold Turbo Pump Controller Frequency Converters along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.