Shopping Cart ( )

DigiVac StrataVac Model 201 Vacuum Gauge Controller With Two 531 TC Vacuum Senors and an Ethernet Card, Thermocouple Vacuum Gauge, m2012tceth

Condition: New
In Stock
Item#:PN17317
Mfr Part#:m2012tceth
Manufacturer:DigiVac
PRICE:
$1,326.00
Web savings:
$27.00
YOU PAY:
$1,299.00
New DigiVac StrataVac Model 201 Vacuum Gauge Controller With Two 531 TC Vacuum Senors and an Ethernet Card, Thermocouple Vacuum Gauge, m2012tceth
Features:
  • Highly adaptable
  • Two Varian 531 TC sensors included
  • Multi-gauge controller
  • Ethernet

DigiVac StrataVac Model 201 Vacuum Gauge Controller With Two 531 TC Vacuum Senors and an Ethernet Card, Thermocouple Vacuum Gauge, m2012tceth

 

DigiVac 201 Overview:


The DigiVac Model 201 series gauge controller is a highly configurable digital vacuum control instrument capable of driving and combining multiple sensors. This device can save space, money and complexity by combining many tasks into one device while enabling the user to have any level of accuracy desired for different ranges. It is a highly flexible multi gauge controller that accepts different inputs based on driver board and sensor election, and can have different outputs including: Analog Recorder, RS232, Ethernet, SPDT relays and VLC outputs. The 201 is configured with sensors based on the accuracy and range required to sense vacuum, and displays the pressure reading in user selectable units of: Torr, mbar or kilopascal. The Model 201 can either be panel mounted or sit on a bench top, and can use thermocouple, capacitance manometer, PCG750, CDG500, or PVG500 Active Gauges. The 201 has a built in feature that displays "range" when the sensor is below its useful range to minimize confusion when looking at multiple instruments. It displays "error" if there is a sensor input fault, and puts any configured relays immediately to the safe atmospheric setting. The 201 also has a rich command set to empower the user to control the set points and PID variables via a local RS232 session or from a web browser a world away.

When purchased with the optional VLC control, the Model 201 regulates the vacuum level at a particular set point between 30 millitorr and 5000 millitorr. This vacuum regulator works on the principal of regulating the bleed of a vacuum vessel to atmosphere much like the way many freeze dryers do. The VLC option also has PID variables to enable the user to adjust the nature of the control. The 201 is intuitive, requires very little setup which makes it easy to control a process or perform precision experimentation.

The instrument equipped with Ethernet gives the user the power of the ReAct browser to remotely monitor and control all aspects of the 201. The 201 greatly facilitates process control and easy data sharing to simplify production and laboratory work.

The DigiVac Model 201 configured with a Varian 531 Thermocouple gauge tube senses vacuum by measuring the temperature rise of an electrically heated thermocouple exposed to a vacuum. As vacuum increases, or, more correctly, as absolute pressure decreases, fewer and fewer molecules of gas are available to cool the thermocouple. With fewer molecules the air temperature rises and the thermocouple gauge thus senses the vacuum. A precision reference inside the DIGIVAC in conjunction with an integrated circuit amplifier controls the electrical excitation of the sensor filament

The DigiVac Model 201 configured with a capacitance manometer or other active gauge displays the vacuum level that corresponds to the sensor voltage output. The DigiVac Model 201 has a total of 4 slots that can be populated by expansion boards.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 


A&J Vacuum Services offers full repair/service of DigVac Portable Vacuum, along with all other brands offered on our website. AJVS also services DigiVac. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

DigiVac StrataVac Model 201 Vacuum Gauge Controller With Two 531 TC Vacuum Senors and an Ethernet Card, Thermocouple Vacuum Gauge, m2012tceth

 

DigiVac 201 Technical Data:


Range: 1 x 10-5 - 760 Torr​
Units: Torr, mBar or kPa
Vac Interface: 1/8" MNPT
Sensor: Varian 531, CM, Active
Sensor Cable Length: 10 Feet
Display: .38" 6 Digit Red LED
Dimensions: 1.7" x 3.52" x 5.35"
Analog Output: (if applicable) 0-5 VDC
Power: 100-240 VAC, 50/60 Hz, CE rated
Controls: 7 Amp, 250 Volt (if applicable)
Mounting: 1/8 DIN or Bench Top

A&J Vacuum Services offers full repair/service of DigVac Portable Vacuum, along with all other brands offered on our website. AJVS also services DigiVac. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.