Shopping Cart ( )

Leybold Replacement Anode Ring, Penningvac 90 N 225 N 237 N, 20028711V02

Condition: Discontinued
Item#:PN23162
Mfr Part#:20028711V02
Manufacturer:Leybold
This product has been discontinued and is no longer available for sale
VIEW REPLACEMENT
Discontinued Leybold Replacement Anode Ring, Penningvac 90 N 225 N 237 N, 20028711V02
Features:
  • This product has been discontinued and is replaced by PN24505
12 months warranty

Leybold Replacement Anode Ring, Penningvac 90 N 225 N 237 N, 20028711V02

Leybold PTR 90 N Penningvac Overview:


This is a Anode ring for the Penningvac PTR 90N, 225N, 237N

The Leybold Penningvac PTR 90N Vacuum Gauge  head combines the cold cathode ionization principle with the Pirani measurement system and mey be operated with modern display and operation instruments.

The Leybold PTR 90 transmeters offer the capability of single port pressure measurement in the range from atmosphere to 10-9 mbar.

The Leybold Penningvac PTR 90N 230088V02 Transmiters are equipped with rugged cold cathode measurement cell for integration within programmable systems. They offer a high level of reproducibility combined with low tendency to collect contamination even in argon operation.

 

Leybold PTR 90 N Penningvac, 230070V02

 

Leybold PTR 90 Sensor Technology


PTR 90 N transmiter contain two separate sensor elements. The MEMS Pirani (MEMS = Micro-Electro-MechanicalSystem) sensor element is based on measurement of thermal conductivity. The MEMS Pirani sensor consists of a silicon chip with a heated resistive element forming one surface of a cavity.

A cover on top of the chip forms the other surface of the cavity. Due to the geometry of the sensor, convection cannot take place within the cavity and consequently the sensor is insensitive to mounting position. Gas molecules are passed by diffusion only to the heated element where the heat loss of the gas is measured. The cold cathode inverted magnetron utilizes a high voltage anode, cathode and a permanent magnet.

Electrons are accelerated towards the anode and will ionize molecules by collision. The magnetic field deflects the electrons, causing them to spiral as they move across the magnetic field to the anode. This spiraling movement increases the opportunity for them to encounter and ionize the molecules. The ionization of the molecules creates an electric current as a function of the pressure. Both sensor elements are very robust and can withstand high G-forces and fast inrushes of air.

 

Leybold PTR90 N Dimensions:


Leybold PTR 90N Penningvac, DN 25 ISO-KF, 230070V02

 


Click Here for PenningVac PTR90N Trnasmitter Operating Manual

Click Here for Leybold Vacuum Measurement Active Sensors Broshure


A&J Vacuum services and repairs Leybold Scroll Vacuum Pumps, Leybold Turbo Pump repair along with all other Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

This item is non-returnable/non-refundable
Item#:PN20232
Mfr Part#:230088V02
Condition: Ships Within 1-3 Weeks New
$2,100.00
Item#:PN20233
Mfr Part#:230070V02
Condition: Out of Stock Discontinued
Price upon request
Item#:PN20234
Mfr Part#:230071V02
Condition: Out of Stock Discontinued
Price upon request
Item#:PN20236
Mfr Part#:230072V02
Condition: Out of Stock Discontinued
$2,264.00
Item#:PN20238
Mfr Part#:230085V02
Condition: Out of Stock Discontinued
Price upon request
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.