Shopping Cart ( )

Leybold TURBOLAB Core 90i, with Scrollvac 3S+, 501591V01023100

Condition: New
Item#:PN57635
Mfr Part#:501591V01023100
Manufacturer:Leybold
New Leybold TURBOLAB Core 90i, with Scrollvac 3S+, 501591V01023100
Features:
  • Flange 63 CF
  • Pumping Speed: 90 m^3/h
  • Ultimate Pressure: 5.000 × 10⁻¹⁰ mbar
  • SCROLLVAC 3S Plus

Leybold TURBOLAB Core 90i, with Scrollvac 3S+, 501591V01023100


 

Leybold TURBOLAB Core 90i Features:


  • Flange: 63 CF
  • Pumping Speed: 90 m^3/h
  • Ultimate Pressure: <8x10-8 mbar


TURBOLAB Core 90i / 501591V01023100 Overview:


The Leybold TURBOLAB Core offers a cost-effective and user-friendly solution by combining a turbomolecular pump, a backing pump, and a basic controller, all mounted on a sturdy baseplate. This integrated design makes it an ideal choice for a wide range of general laboratory applications.

 

TURBOLAB Core90 Applications:


  • High energy physics / accelerators
  • High vacuum and ultra-high vacuum systems
  • Analytics
  • Surface science
  • Industrial vacuum applications
  • Small coating processes
  • Custom mass spectrometers and leak detectors
  • Residual gas analyzers

 

A&J Vacuum services and repairs Leybold Scroll Vacuum Pumps, Leybold Turbo Pump Station repair along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Leybold TURBOLAB Core 90i, with Scrollvac 3S+, 501591V01023100

 

Leybold TURBOLAB Core 90i Technical Data:

Connector Electrical Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Connection Outlet Flange DN 16 ISO-KF (NW16)
Connection Inlet Flange DN 63 CF (4.5")
Cooling Method Air Cooling (forced - fan)
Dimension Height 0.248 m
Dimension Length 0.420 m
Dimension Width 0.300 m
IP Rating IP20
Power Supply Frequency 50 Hz
60 Hz
Power Supply Phase 1-Ph
Power Supply Voltage 1Ph 115V 50/60Hz
Weight 24 kg | 53 lb
Connection Inlet / Outlet Flange DN 63 CF (4.5") | DN 16 ISO-KF (NW16)
Classification Dry or Wet Pump Dry
Classification Product Pressure Range

High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Ultra High Vacuum: 1·10⁻⁷ - 1·10⁻¹¹ mbar

Classification Region US
Power at Ultimate 500 W
Pressure Ultimate 5.000 × 10⁻¹⁰ mbar
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.090 m³/s
Altitude Max 2000 m
Variant of Backing Pump SCROLLVAC 3S plus

 

A&J Vacuum services and repairs Leybold Scroll Vacuum Pumps, Leybold Turbo Pump Station repair along with all other Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.