Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF 10 and EMF 20, A50420000
Item#: PN07053 Mfr Part#: A50420000 Manufacturer: Edwards Vacuum
Condition: New In Stock
New Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF10 and EMF20, A50420000, A504-20-000

Features:
  • OEM P/N A50420000

PRICE: $392.00
WEB SAVINGS: $7.00
YOU PAY: $385.00
Item#: PN07053 Mfr Part#: A50420000
Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF 10 and EMF 20, A50420000
Item#: PN07053 Mfr Part#: A50420000 Manufacturer: Edwards Vacuum

Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF10 and EMF20, A50420000, A504-20-000


Overview:

The Edwards Vacuum Clean Application Oil Return Kit A50420000 conserve the pump oil, by returning the oil trapped in the mist filter to the pump.

When fitted, the oil return kit returns oil trapped in the oil mistfilter back to the pump, through the gas ballast port. This Edwards Oil Return kit reduces oil loss from the pump and laso reduces the need to check the oil level in the pump.

This oil Return kit can be only used if the gases pumped do not contaminate the oil. On all Edwards E1M18, E2M18, E2M28, E2M30 pumps Oil Drain Kit is fitted in place of gas ballast control knob.

In normal operation, the oil level will be at or below the level of the drain adaptor on the Edwards EMF oil mist filter.

Edwards Oil Return Kit is designed to fit the following pump models:

Edwards E1M18

Edwards E2M18

Edwarda E1M28

Edwards E2M28

 


 

Please refer to operation manual for detailed instalation instructions and application instructions.

Edwards Oil Return kit is usualy used with Edwards EMF10 / A46226000 /  PN00837 and Edwards EMF20  / A46229000 / PN00844  Oil Mist Filters.

Edwards Mist Elements and Odor Elements can also be purchased seperately and replaced when needed.

Mist Element for Edwards EMF 10 / A22304198 / Ordering number PN06387

Odor Element for Edwards EMF 10 / A22304198 / Ordering number PN06386


Mist Element for Edwards EMF 20 / A22304199 / Ordering number PN06389

Odor Element for Edwards EMF 20 / Ordering number PN06388


A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF10 and EMF20, A50420000, A504-20-000

Edwards Oil Return Kit is designed to fit the following pump models:

Edwards E1M18

Edwards E2M18

Edwarda E1M28

Edwards E2M28

 


Please refer to operation manual for detailed instalation instructions and application instructions.

Edwards Oil Return kit is usualy used with Edwards EMF10 / A46226000 /  PN00837 and Edwards EMF20  / A46229000 / PN00844  Oil Mist Filters.

Edwards Mist Elements and Odor Elements can also be purchased seperately and replaced when needed.

Mist Element for Edwards EMF 10 / A22304198 / Ordering number PN06387

Odor Element for Edwards EMF 10 / A22304198 / Ordering number PN06386


Mist Element for Edwards EMF 20 / A22304199 / Ordering number PN06389

Odor Element for Edwards EMF 20 / Ordering number PN06388


A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF 10 and EMF 20, A50420000
Item#: PN07053 Mfr Part#: A50420000 Manufacturer: Edwards Vacuum

Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF10 and EMF20, A50420000, A504-20-000


Overview:

The Edwards Vacuum Clean Application Oil Return Kit A50420000 conserve the pump oil, by returning the oil trapped in the mist filter to the pump.

When fitted, the oil return kit returns oil trapped in the oil mistfilter back to the pump, through the gas ballast port. This Edwards Oil Return kit reduces oil loss from the pump and laso reduces the need to check the oil level in the pump.

This oil Return kit can be only used if the gases pumped do not contaminate the oil. On all Edwards E1M18, E2M18, E2M28, E2M30 pumps Oil Drain Kit is fitted in place of gas ballast control knob.

In normal operation, the oil level will be at or below the level of the drain adaptor on the Edwards EMF oil mist filter.

Edwards Oil Return Kit is designed to fit the following pump models:

Edwards E1M18

Edwards E2M18

Edwarda E1M28

Edwards E2M28

 


 

Please refer to operation manual for detailed instalation instructions and application instructions.

Edwards Oil Return kit is usualy used with Edwards EMF10 / A46226000 /  PN00837 and Edwards EMF20  / A46229000 / PN00844  Oil Mist Filters.

Edwards Mist Elements and Odor Elements can also be purchased seperately and replaced when needed.

Mist Element for Edwards EMF 10 / A22304198 / Ordering number PN06387

Odor Element for Edwards EMF 10 / A22304198 / Ordering number PN06386


Mist Element for Edwards EMF 20 / A22304199 / Ordering number PN06389

Odor Element for Edwards EMF 20 / Ordering number PN06388


A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards Oil Return Kit for E1M18, E2M18, E2M28, E2M30 with EMF10 and EMF20, A50420000, A504-20-000

Edwards Oil Return Kit is designed to fit the following pump models:

Edwards E1M18

Edwards E2M18

Edwarda E1M28

Edwards E2M28

 


Please refer to operation manual for detailed instalation instructions and application instructions.

Edwards Oil Return kit is usualy used with Edwards EMF10 / A46226000 /  PN00837 and Edwards EMF20  / A46229000 / PN00844  Oil Mist Filters.

Edwards Mist Elements and Odor Elements can also be purchased seperately and replaced when needed.

Mist Element for Edwards EMF 10 / A22304198 / Ordering number PN06387

Odor Element for Edwards EMF 10 / A22304198 / Ordering number PN06386


Mist Element for Edwards EMF 20 / A22304199 / Ordering number PN06389

Odor Element for Edwards EMF 20 / Ordering number PN06388


A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.