Shopping Cart ( )

Pfeiffer TC 1200 Electronic Drive Unit with Profibus for HiPace 1200-2300 Turbo Vacuum Pumps, 2000016998 / PM C01 812 DE / PMC01812DE

Condition: New
Item#:PN18265
Mfr Part#:2000016998 / PM C01 812 DE / PMC01812DE
Manufacturer:Pfeiffer Vacuum
PRICE:
$4,700.00
Web savings:
$505.00
YOU PAY:
$4,195.00
New Pfeiffer TC 1200 Electronic Drive Unit with Profibus for HiPace 1200-2300 Turbo Vacuum Pumps, 2000016998 / PM C01 812 DE / PMC01812DE
Features:
  • PMC01812DE
  • Turbopump Hipace: 1200, 1500, 1800, 2300
  • Mains requirement: voltage (range) : 100-120/200-240 (+/- 10%) V AC
  • Protection category IP54
12 months warranty

Pfeiffer TC 1200 Electronic Drive Unit with Profibus for HiPace 1200-2300 Turbo Vacuum Pumps, 2000016998 / PM C01 812 DE / PMC01812DE


 

TC 1200 Electronic Drive Unit / PMC01812DE Overview:


The electronic drive unit TC 1200 is an integrated component of the turbopump. It's purpose is to drive, monitor and control the entire pump. 

To correctly identify the product when communicating with Pfeiffer Vacuum, always have the information from the rating plate available. 

A Pfeiffer Vacuum display and control panel (DCU or HPU) or an external PC can be connected to the electronic drive unit via the connection designated "RS-485". The interface is electrically isolated from the maximum supply voltage of the electronic drive unit. The electrical couplings are optically decoupled internally.

 

A&J Vacuum repair / rebuild and service Pfeiffer  HiPace Turbo Pumps, Pfeiffer Backing  Pumps along with all other  Pfeiffer  Vacuum Pumps and all other Pfeiffer Leak Detector  Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Pfeiffer TC 1200 Electronic Drive Unit with Profibus for HiPace 1200-2300 Turbo Vacuum Pumps, 2000016998 / PM C01 812 DE / PMC01812DE

 

Pfeiffer Vacuum TC 1200 Electronic Drive Unit Technical Data:

Pfeiffer Vacuum TC 1200 Technical Data, PMC01812BT, PM C01 812 BT

 

A&J Vacuum repair / rebuild and service Pfeiffer  HiPace Turbo Pumps, Pfeiffer Backing  Pumps along with all other  Pfeiffer  Vacuum Pumps and all other Pfeiffer Leak Detector  Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.