phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230
Item#: PN57908 Mfr Part#: PT Q90 211 230 / PTQ90211230 Manufacturer: Pfeiffer Vacuum
Condition:
New
New Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230

Features:
  • Quartz Capillary
  • 100 – 240 V AC, 50/60 Hz
  • Mass Range: 1 - 300 u
  • Gas Connection Length: 2 m | 79 in

Price upon request
Item#: PN57908 Mfr Part#: PT Q90 211 230 / PTQ90211230
Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230
Item#: PN57908 Mfr Part#: PT Q90 211 230 / PTQ90211230 Manufacturer: Pfeiffer Vacuum

Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230


 

Pfeiffer ThermoStar GSD 350 T3 Features:


  • Analyzes multiple gas components simultaneously
  • Ethernet interface type
  • Gas connection length of 2 m | 79 in

 

ThermoStar GSD 350 T3 / PTQ90211230 Overview:


The Pfeiffer GSD 350 is capable of simultaneously analyzing multiple gas components. Before entering the PrismaPro, the sample gas passes through a pressure-reduction stage to ensure proper operating conditions in the vacuum environment. Within the PrismaPro, a portion of the gas is ionized, and the resulting ions are separated and detected according to their respective mass-to-charge ratios.

Two GSD350 configurations are available, each featuring a different gas inlet system (OmniStar or ThermoStar). The inlet system reduces the sample gas pressure from 1000 hPa to the working pressure required by the PrismaPro. Both versions share the same gas analysis unit as well as the high-vacuum and gas-handling system.

 

ThermoStarGSD350T3 Scope of Delivery:


  • GSD 350 OmniStar/ThermoStar
  • Installation hardware and small parts
    • Allen key, WAF 2, WAF 2.5 AND WAF 3
    • Metric open-end wrench, WAF 8, WAF 10 (2x) and WAF 14
    • Imperial open-end wrench, WAF 5/16", WAF 3/8" and WAF 9/16"
    • Two-sided socket key for the ion source
    • Special tool for the orifice of the gas inlet system
    • 2 O-rings made of FKM, 9.25 × 1.78 mm and 18.77 × 1.78 mm
    • 2 slow fuses, 10 A
    • For OmniStar with stainless steel capillary only
      • Hexagon socket wrench, TX20
      • Clamp collar set for 1/16" tube (5 pieces)
    • For ThermoStar or GSD 350 with quartz capillary only
      • Sealing set for capillary 250 µm (ferrule) (5 pieces)
  • Transport protection for analyzer QMA 250 M
  • Assembly aid for analyzer QMA 250
  • Ethernet cable, 3 m length, red
  • Mains Cable
  • Operating instructions
    • GSD 350 OmniStar/ThermoStar
    • Components

 

ThermoStarGSD350T3 Applications:


  • Battery
    • Degassing
    • Recycling
  • Carbon Capture
    • Amine Scrubbing
    • Membrane Capture
    • Moving Bed Process
    • Pressure Swing Adsorption
    • Direct Air Capture
  • Pharmaceutical Industry
    • Laboratory Vacuum
  • R&D
    • Laboratory Vacuum
  • Scientific Instruments
    • Surface Analysis

 

A&J Vacuum repair / rebuild and service Leak Detectors & Mass Spectrometers and all other Pfeiffer equipment available on our site. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230

 

Pfeiffer ThermoStar GSD 350 T3 Technical Data:

Ambient temperature 10 – 40 °C  |  50 – 104 °F |  283.15 – 313.15 K
Calibration device No
Capillary, material Quartz
Contribution to neighboring mass: 40 to 41 < 50 ppm
Corrosive gas version No
Detection limit min.: C-SEM (ppm) < 10 ppm
Exhaust connection IQS plug-in connection, 6 mm | 0.24 in
Exhaust pressure, max.  Atmospheric pressure
Filament Iridium coated with Y2O3
Gas connection Capillary, AD 0.23 mm | 0.01 in
Gas connection: Length 2 m | 0.1 in
Gas flow rate 1 – 2 sccm (0 °C)  |  33.8 – 35.6 °F |  274.15 – 275.15 K
Gas inlet Continuously open
Grain size limit (separable) 1 µm
Inlet pressure max.  1200 hPa  |  900 Torr |  1,200 mbar
Input voltage(s) 100 – 240 V AC, 50/60 Hz
Input: Analog 5 x, -10 – +10 V / 14 Bit | 16 Bit
Input: Digital 4 x nominal + 24 V
Interface: Type Ethernet
Mains frequency compatibility 50 Hz
60 Hz
Mass range  1 - 300 u
Materials in contact with media Ceramic
Stainless steel
Copper
Nickel
Molybdenum
Gold
Glass
FKM
PTFE
Platinum/iridium
Aluminum
Silver
NBR
Number of filaments 2
Operating altitude, max. 2000 m
Operating site Indoor, weatherproof
Operating temperature: capillary, up to 200 °C |  392 °F |  473.15 K
Output: Analog 4 x, 0 – 10 V, Imax = 10 mA, 16 bit
Output: Digital 6 x open collector, nominal + 24 V, Imax = 200 mA
Power consumption 830 W
Protection degree IP30
Recommended on-site electric fuse protection 10 A
Relay: Number 2 pcs.
Relay: Switching current 1 A
Relay: Switching voltage 24 V DC
System controller Color 7" touch display or via web interface

 

A&J Vacuum repair / rebuild and service Leak Detectors & Mass Spectrometers and all other Pfeiffer equipment available on our site. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Name
Price
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230
Item#: PN57908 Mfr Part#: PT Q90 211 230 / PTQ90211230 Manufacturer: Pfeiffer Vacuum

Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230


 

Pfeiffer ThermoStar GSD 350 T3 Features:


  • Analyzes multiple gas components simultaneously
  • Ethernet interface type
  • Gas connection length of 2 m | 79 in

 

ThermoStar GSD 350 T3 / PTQ90211230 Overview:


The Pfeiffer GSD 350 is capable of simultaneously analyzing multiple gas components. Before entering the PrismaPro, the sample gas passes through a pressure-reduction stage to ensure proper operating conditions in the vacuum environment. Within the PrismaPro, a portion of the gas is ionized, and the resulting ions are separated and detected according to their respective mass-to-charge ratios.

Two GSD350 configurations are available, each featuring a different gas inlet system (OmniStar or ThermoStar). The inlet system reduces the sample gas pressure from 1000 hPa to the working pressure required by the PrismaPro. Both versions share the same gas analysis unit as well as the high-vacuum and gas-handling system.

 

ThermoStarGSD350T3 Scope of Delivery:


  • GSD 350 OmniStar/ThermoStar
  • Installation hardware and small parts
    • Allen key, WAF 2, WAF 2.5 AND WAF 3
    • Metric open-end wrench, WAF 8, WAF 10 (2x) and WAF 14
    • Imperial open-end wrench, WAF 5/16", WAF 3/8" and WAF 9/16"
    • Two-sided socket key for the ion source
    • Special tool for the orifice of the gas inlet system
    • 2 O-rings made of FKM, 9.25 × 1.78 mm and 18.77 × 1.78 mm
    • 2 slow fuses, 10 A
    • For OmniStar with stainless steel capillary only
      • Hexagon socket wrench, TX20
      • Clamp collar set for 1/16" tube (5 pieces)
    • For ThermoStar or GSD 350 with quartz capillary only
      • Sealing set for capillary 250 µm (ferrule) (5 pieces)
  • Transport protection for analyzer QMA 250 M
  • Assembly aid for analyzer QMA 250
  • Ethernet cable, 3 m length, red
  • Mains Cable
  • Operating instructions
    • GSD 350 OmniStar/ThermoStar
    • Components

 

ThermoStarGSD350T3 Applications:


  • Battery
    • Degassing
    • Recycling
  • Carbon Capture
    • Amine Scrubbing
    • Membrane Capture
    • Moving Bed Process
    • Pressure Swing Adsorption
    • Direct Air Capture
  • Pharmaceutical Industry
    • Laboratory Vacuum
  • R&D
    • Laboratory Vacuum
  • Scientific Instruments
    • Surface Analysis

 

A&J Vacuum repair / rebuild and service Leak Detectors & Mass Spectrometers and all other Pfeiffer equipment available on our site. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Pfeiffer ThermoStar GSD 350 T3, 1 - 300 u, Yttrium Iridium Cathode, Heated Capillary 200 °C, 1A, PT Q90 211 230 / PTQ90211230

 

Pfeiffer ThermoStar GSD 350 T3 Technical Data:

Ambient temperature 10 – 40 °C  |  50 – 104 °F |  283.15 – 313.15 K
Calibration device No
Capillary, material Quartz
Contribution to neighboring mass: 40 to 41 < 50 ppm
Corrosive gas version No
Detection limit min.: C-SEM (ppm) < 10 ppm
Exhaust connection IQS plug-in connection, 6 mm | 0.24 in
Exhaust pressure, max.  Atmospheric pressure
Filament Iridium coated with Y2O3
Gas connection Capillary, AD 0.23 mm | 0.01 in
Gas connection: Length 2 m | 0.1 in
Gas flow rate 1 – 2 sccm (0 °C)  |  33.8 – 35.6 °F |  274.15 – 275.15 K
Gas inlet Continuously open
Grain size limit (separable) 1 µm
Inlet pressure max.  1200 hPa  |  900 Torr |  1,200 mbar
Input voltage(s) 100 – 240 V AC, 50/60 Hz
Input: Analog 5 x, -10 – +10 V / 14 Bit | 16 Bit
Input: Digital 4 x nominal + 24 V
Interface: Type Ethernet
Mains frequency compatibility 50 Hz
60 Hz
Mass range  1 - 300 u
Materials in contact with media Ceramic
Stainless steel
Copper
Nickel
Molybdenum
Gold
Glass
FKM
PTFE
Platinum/iridium
Aluminum
Silver
NBR
Number of filaments 2
Operating altitude, max. 2000 m
Operating site Indoor, weatherproof
Operating temperature: capillary, up to 200 °C |  392 °F |  473.15 K
Output: Analog 4 x, 0 – 10 V, Imax = 10 mA, 16 bit
Output: Digital 6 x open collector, nominal + 24 V, Imax = 200 mA
Power consumption 830 W
Protection degree IP30
Recommended on-site electric fuse protection 10 A
Relay: Number 2 pcs.
Relay: Switching current 1 A
Relay: Switching voltage 24 V DC
System controller Color 7" touch display or via web interface

 

A&J Vacuum repair / rebuild and service Leak Detectors & Mass Spectrometers and all other Pfeiffer equipment available on our site. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.