Shopping Cart ( )

Alcatel 5150 Turbomolecular High Vacuum Pump

Condition: Remanufactured
In Stock
Item#:PN00190
Mfr Part#:5150ISO100
Manufacturer:Adixen / Alcatel
PRICE:
$5,750.00
Web savings:
$1,650.00
YOU PAY:
$4,100.00
Remanufactured Alcatel 5150 Turbo Pump with ISO100 Inlet Flange, KF25 Outlet Flange.Pumping speed: for N2 140 l/s, Ultimate pressure with rotary vane pump 1x10-9 mbar, Recommended Backing Pump 1.5-16 m3.
Features:
  • DN 100 ISO-K Inlet Flange
  • Fully Remanufactured
12 months warranty

Alcatel 5150 Turbo Molecular High Vacuum Pump Fully Remanufactured and Rebuild


  • Pumping speed: for N2 140 l/s,
  • Ultimate pressure with rotary vane pump 1x10-9 mbar,
  • Recommended Backing Pump 1.5-16 m3.
  • Air Cooling available.
  • Turbo pump designed for a wide range of applications in research industry, Space simulation, Thin film deposition, Ion source, Mass spectrometer, leak detection.
  • The Alcatel CFF -450 Turbo Pump controller is needed to operate Alcatel 5150 Turbo Pump.

 


A&J Vacuum also repair / rebuild and service Alcatel 5150, Alcatel 5150 CF Turbo Pumps, Adixen rotary vane pumps  along with all other Pfeiffer and Alcatel Turbo Pumps . Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Alcatel 5150 Turbo Molecular High Vacuum Pump Fully Remanufactured and Rebuild


  • Pumping speed: for N2 140 l/s,
  • Ultimate pressure with rotary vane pump 1x10-9 mbar,
  • Recommended Backing Pump 1.5-16 m3.
  • Air Cooling available.
  • Turbo pump designed for a wide range of applications in research industry, Space simulation, Thin film deposition, Ion source, Mass spectrometer, leak detection.
  • The Alcatel CFF -450 Turbo Pump controller is needed to operate Alcatel 5150 Turbo Pump.

 


A&J Vacuum also repair / rebuild and service Alcatel 5150, Alcatel 5150 CF Turbo Pumps, Adixen rotary vane pumps  along with all other Pfeiffer and Alcatel Turbo Pumps . Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Item#:PN07083
Mfr Part#:
Condition: Out of Stock Remanufactured
Out of Stock
Price upon request
Item#:PN07084
Mfr Part#:
Condition: Out of Stock Remanufactured
Out of Stock
Price upon request
Item#:PN00316
Mfr Part#:8220
Condition: In Stock Remanufactured
In Stock
$1,450.00
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.