Shopping Cart ( )

Alcatel 2008AC Chemical Resistant Rotary Vane Pump

Condition: Remanufactured
Call us for Availability
Item#:PN06420
Mfr Part#:
Manufacturer:Adixen / Alcatel
Remanufactured Fully rebuilt Alcatel 2008AC (2008AC) Chemical Resistant Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange
Features:
  • Inlet Flange: KF 25
  • Outlet Flange: KF 25
  • Ultimate Pressure: 1 x 10-3 Torr
  • Pumping Speed: 7 cfm
12 months warranty

Fully rebuilt Alcatel 2008AC (2008AC) Chemical Resistant Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange

 

Alcatel 2008AC Overview:


Fully refurbished Alcatel 2008AC Chemical Resistant Rotary Vane Pump coupled with a KF25 Inlet Flange and KF25 Outlet Flange. This Alcatel Rotary Vane Pump has a peak pumping velocity of 7cfm and a final pressure of 1 x 10-3 Torr. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries. The Alcatel 2008AC Pump comes with an entire 12-Month Warranty.

 

Alcatel 2008AC Applications:


  • Gas analyzers
  • Leak detection
  • Mass spectrometers
  • Other spectrometers
  • Electron microscopes
  • Surface analyzers
  • Centrifuges
  • Sterilization
  • Electron tubes
  • Lamps
  • TV tubes (CRT)
  • Refrigeration
  • Air conditioning
  • Drying
  • Distillation
  • Metallurgy
  • Free drying
  • CVD.LPCVD
  • Ion implantation
  • Dry etching
  • Load-lock
  • Cryogenics
  • Gas recovery
  • Oxygen pumping

A&J Vacuum also repair / rebuild and service all Alcatel 2008AC Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Fully rebuilt Alcatel 2008AC (2008AC) Chemical Resistant Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange

 

Alcatel 2008AC Overview:


Inlet Flange: KF 25
Outlet Flange: KF 25
Pumping Speed: 7 cfm
Ultimate Pressure: 1 x 10-3 Torr

A&J Vacuum also repair / rebuild and service all Alcatel 2008AC Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Item#:PN09917
Mfr Part#:52582
Condition: Ships Within 1-3 Days New
$358.00
Item#:PN09963
Mfr Part#:53106FR
Condition: In Stock New
In Stock
$40.20
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.