Shopping Cart ( )

Edwards Remote Control (Gameboy) To Be Used With The iQDP Semiconductor Pumping System, D37209000

Condition: Remanufactured
In Stock
Item#:PN14572
Mfr Part#:D37209000
Manufacturer:Edwards Vacuum
Remanufactured Edwards Remote Control (Game boy) To Be Used With The iQDP Semiconductor Pumping System, D37209000, D372-09-000
Features:
  • P/N D37209000
6 months warranty

Edwards Remote Control (Game boy) To Be Used With The iQDP Semiconductor Pumping System, D37209000, D372-09-000

 

Edwards Remote Control Overview:


The End User Controller (EUC) allows manual control of the EPX pump and also displays the pump status.

Use the run button to start the EPX pump. The run button has an LED which is on when the EPX pump is running. Use the stop button to stop the pump.

The display shows two lines of text; each line is 16 characters long. In normal operation, the Normal display is shown; the Normal display has two pages, and each has two lines. Each page of the Normal display shows the status of one or more EPX EUC sensors or internal clocks and counters. As supplied, the first page of Normal display shows the pump serial number and pump current. It is possible to change the information shown on the Normal display.

At any time, press one of the four menu buttons to select a new menu. Then use the up, down , ENTER and CANCEL buttons to move through the menu. The appropriate menu selected LED is on when the corresponding menu is in use.

Use the menu, up, down, CANCEL and ENTER buttons as described below:

  • Status: Press this button to select the Status menu. This menu displays the current pump status.
  • Normal: Press this button to select the Normal display.
  • Control: Press this button to select the Control menu, then take control or release control of the pumping system.
  • Setup: Press this button to select the Setup menu. In this menu it is possible to display parameters (such as the pressure units used when pressures are displayed).
  • Enter (6): Use this button to select a currently displayed menu option or to enter a currently displayed parameter.
  • Cancel (4): Use this button to cancel the currently displayed menu or option and return to the previous menu or
    option.
  • Up (5)/Down (3): Use these buttons to move up or down menu options or to increase or decrease a displayed
    parameter.
  • The status LEDs show the current status of the EPX system.
  • Alarm: This LED shows when an alarm condition exists.
  • Warning: This LED shows when a warning condition exists.
  • Local control: This LED is on when the EUC has control of the EPX system.

The ALARM and WARNING LEDs flash when the corresponding alarm or warning condition first occurs. When acknowledging the condition, the corresponding LED goes on permanently. For most alarms and warnings, if the condition clears (that is, the fault which caused the condition is no longer present), the corresponding LED goes off once the condition has been acknowledged.

 

Edwards Remote Control Front Panel:


Edwards Dry Pump Remote Control (Gameboy), D37272000

 


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.