phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer DCU-002 Display Control Unit for HiPace pumps, PM061348AT / PM 061 348, DCU 002
Item#: PN06197 Mfr Part#: PM061348AT / PM 061 348 Manufacturer: Pfeiffer Vacuum
Condition: Discontinued
Discontinued Pfeiffer Vacuum DCU 002 Display Control Unit for HiPace pumps, PM061348T Dry and oil-free diaphragm pumps with a pumping speed of 6 to 160 l/min

Features:
  • P/N PM061348-T
  • 12 Months Warranty
  • Like New !!!

This product has been discontinued and is no longer available for sale
Item#: PN06197 Mfr Part#: PM061348AT / PM 061 348
Pfeiffer DCU-002 Display Control Unit for HiPace pumps, PM061348AT / PM 061 348, DCU 002
Item#: PN06197 Mfr Part#: PM061348AT / PM 061 348 Manufacturer: Pfeiffer Vacuum

New Pfeiffer DCU-002 Display Control Unit, PM061348T Display DCU 002 Digital Display, PM 061 348-T

  • Display and operating instrument for Pfeiffer Vacuum drive instruments
  • Ensures the control of all parameters of these instruments
  • Power supply exlusively from Pfeiffer electronic drive unit (connection cable Pfeiffer Vacuum DCU002 - TM 3000 see accessories)

Pfeiffer DCU002 Characteristics:

Power Consumption: 5 VA

Suitable for all Hipace series

Electronic Drive unit:

  • TC 110
  • TC 120
  • TC 400
  • TM 700
  • TC 1200


 

 

A&J Vacuum repair / rebuild and service all Pfeiffer Vacuum Diaphragm Dry Pumps along with all other  Pfeiffre Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

 

 

 

New Pfeiffer DCU-002 Display Control Unit, PM061348T Display DCU 002 Digital Display, PM 061 348-T

  • Display and operating instrument for Pfeiffer Vacuum drive instruments
  • Ensures the control of all parameters of these instruments
  • Power supply exlusively from Pfeiffer electronic drive unit (connection cable Pfeiffer Vacuum DCU002 - TM 3000 see accessories)

Pfeiffer DCU002 Characteristics:

Power Consumption: 5 VA

Suitable for all Hipace series

Electronic Drive unit:

  • TC 110
  • TC 120
  • TC 400
  • TM 700
  • TC 1200


 

A&J Vacuum repair / rebuild and service all Pfeiffer Vacuum Diaphragm Dry Pumps along with all other  Pfeiffre Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

 

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer DCU-002 Display Control Unit for HiPace pumps, PM061348AT / PM 061 348, DCU 002
Item#: PN06197 Mfr Part#: PM061348AT / PM 061 348 Manufacturer: Pfeiffer Vacuum

New Pfeiffer DCU-002 Display Control Unit, PM061348T Display DCU 002 Digital Display, PM 061 348-T

  • Display and operating instrument for Pfeiffer Vacuum drive instruments
  • Ensures the control of all parameters of these instruments
  • Power supply exlusively from Pfeiffer electronic drive unit (connection cable Pfeiffer Vacuum DCU002 - TM 3000 see accessories)

Pfeiffer DCU002 Characteristics:

Power Consumption: 5 VA

Suitable for all Hipace series

Electronic Drive unit:

  • TC 110
  • TC 120
  • TC 400
  • TM 700
  • TC 1200


 

 

A&J Vacuum repair / rebuild and service all Pfeiffer Vacuum Diaphragm Dry Pumps along with all other  Pfeiffre Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

 

 

 

New Pfeiffer DCU-002 Display Control Unit, PM061348T Display DCU 002 Digital Display, PM 061 348-T

  • Display and operating instrument for Pfeiffer Vacuum drive instruments
  • Ensures the control of all parameters of these instruments
  • Power supply exlusively from Pfeiffer electronic drive unit (connection cable Pfeiffer Vacuum DCU002 - TM 3000 see accessories)

Pfeiffer DCU002 Characteristics:

Power Consumption: 5 VA

Suitable for all Hipace series

Electronic Drive unit:

  • TC 110
  • TC 120
  • TC 400
  • TM 700
  • TC 1200


 

A&J Vacuum repair / rebuild and service all Pfeiffer Vacuum Diaphragm Dry Pumps along with all other  Pfeiffre Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.