Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)
Item#: PN49003 Mfr Part#: PD100100AT / PD 100 100 AT Manufacturer: Pfeiffer-Vacuum
Condition:
New
New Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)

Features:
  • 5 VDC (±5 %) Input Voltage
  • 100 ms Measuring Cycle
  • IP40 Protection Degree
  • Piezo and Pirani Measuring Methods

Price upon request
Item#: PN49003 Mfr Part#: PD100100AT / PD 100 100 AT
Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)
Item#: PN49003 Mfr Part#: PD100100AT / PD 100 100 AT Manufacturer: Pfeiffer-Vacuum

Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)


 

Pfeiffer RPT 010 / PD100100AT Overview:


The RPT 010 sensor has two measurement systems: the Pirani measurement system and the Piezo-resistive measurement system. It can process requests for measured values, type information, and calibration commands. Signal evaluation occurs through the interfaces of the electronic drive unit, using either a Pfeiffer Vacuum control unit or external devices such as a PLC or PC.

 

RPT010 PD100100AT Features:


  • Stable, coarse vacuum measurement independent of gas type
  • Compact dimensions
  • Direct installation on scroll pump, no additional power supply
  • Additional measurement cable not required
  • Display range: 1 · 10-4 – 1200 hPa
  • Accessory does not have ATEX certification

 

RPT010 PD100100AT Scope of Delivery:


  • Sensor with cable and power supply plug
  • Operating instructions

 

A&J Vacuum Services repairs / rebuilds and services all of the Pfeiffer HiScroll pumps such as the HiScroll 6 / PD S10 000, HiScroll 12 / PD S20 000, HiScroll 18 / PD S30 000, and HiScroll 46 / PD S40 000 as well as other Pfeiffer Vacuum equipment such as their turbomolecular pumps, rotary vane pumps, leak detectors, and more. Please contact us for information about our service program or click here http://www.ajvs.com/service.php to go to our service page. We also offer emergency rush service upon request. For more information please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)


 

Pfeiffer RPT 010 Technical Data:


  • Accuracy of measurement in range 1: 50 % (5E-4 hPa – 1E-3 hPa) | 37.5 – 7.5 · 10-4 Torr | 50 – 1 · 10-3 mbar
  • Accuracy of measurement in range 2: 15 % (1E-3 hPa – 1E2 hPa) | 11.25 – 75 Torr | 15 – 100 mbar
  • Accuracy of measurement in range 3: 1.25 % (full scale) (1E2 hPa – 1.2E3 hPa) | 0.94 – 900 Torr | 1.25 – 1,200 mbar
  • Ambient pressure: 790 – 1060 hPa | 592.5 – 795 Torr | 790 – 1,060 mbar
  • Ambient temperature: 5 – 60 °C | 41 – 140 °F | 278.15 – 333.15 K
  • Certification: CE, cTUVus certified according to UL / CSA 61010-1
  • Connection flange (in): G 1/8''
  • Electrical connection: B industry (micro)
  • Input voltage(s): 5 VDC (±5 %)
  • Interface - Connection, device side: Cable with (micro USB plug)
  • Materials in contact with media: Ceramic, Stainless steel, Tungsten, Silicon oxide, Glass, Araldite, Solder, Nickel
  • Measurement cable length min.: 0.5 m / 20 in
  • Measuring cycle: 100 ms
  • Measuring method: Piezo, Pirani
  • Measuring range: 5E-4 – 1.2E3 hPa | 3.75 · 10-4 – 900 Torr | 5 · 10-4 – 1,200 mbar
  • Mounting orientation: Arbitrary
  • Power consumption: 0.25 W
  • Power consumption max.: 0.25 W
  • Pressure max.: 2 · 103 hPa | 1,500 Torr | 2,000 mbar
  • Protection degree: IP40
  • Repeatability in range 1: 3 % (1E-3 hPa – 1E2 hPa) | 2.25 – 75 Torr | 3 – 100 mbar
  • Repeatability in range 2: 3 % (full scale) (1E1 hPa – 1200 hPa) | 2.25 – 900 Torr | 3 – 1,200 mbar
  • Usage: Only in indoor areas
  • Volume: 0.4 cm³
  • Weight approx.: 0.20lb

 

A&J Vacuum Services repairs / rebuilds and services all of the Pfeiffer HiScroll pumps such as the HiScroll 6 / PD S10 000, HiScroll 12 / PD S20 000, HiScroll 18 / PD S30 000, and HiScroll 46 / PD S40 000 as well as other Pfeiffer Vacuum equipment such as their turbomolecular pumps, rotary vane pumps, leak detectors, and more. Please contact us for information about our service program or click here http://www.ajvs.com/service.php to go to our service page. We also offer emergency rush service upon request. For more information please contact A&J Vacuum Services at 973-249-0854.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)
Item#: PN49003 Mfr Part#: PD100100AT / PD 100 100 AT Manufacturer: Pfeiffer-Vacuum

Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)


 

Pfeiffer RPT 010 / PD100100AT Overview:


The RPT 010 sensor has two measurement systems: the Pirani measurement system and the Piezo-resistive measurement system. It can process requests for measured values, type information, and calibration commands. Signal evaluation occurs through the interfaces of the electronic drive unit, using either a Pfeiffer Vacuum control unit or external devices such as a PLC or PC.

 

RPT010 PD100100AT Features:


  • Stable, coarse vacuum measurement independent of gas type
  • Compact dimensions
  • Direct installation on scroll pump, no additional power supply
  • Additional measurement cable not required
  • Display range: 1 · 10-4 – 1200 hPa
  • Accessory does not have ATEX certification

 

RPT010 PD100100AT Scope of Delivery:


  • Sensor with cable and power supply plug
  • Operating instructions

 

A&J Vacuum Services repairs / rebuilds and services all of the Pfeiffer HiScroll pumps such as the HiScroll 6 / PD S10 000, HiScroll 12 / PD S20 000, HiScroll 18 / PD S30 000, and HiScroll 46 / PD S40 000 as well as other Pfeiffer Vacuum equipment such as their turbomolecular pumps, rotary vane pumps, leak detectors, and more. Please contact us for information about our service program or click here http://www.ajvs.com/service.php to go to our service page. We also offer emergency rush service upon request. For more information please contact A&J Vacuum Services at 973-249-0854.

Pfeiffer RPT 010 Package, PD100100AT / PD 100 100 AT, Digital Piezo/Pirani Sensor, 5 VDC (±5%)


 

Pfeiffer RPT 010 Technical Data:


  • Accuracy of measurement in range 1: 50 % (5E-4 hPa – 1E-3 hPa) | 37.5 – 7.5 · 10-4 Torr | 50 – 1 · 10-3 mbar
  • Accuracy of measurement in range 2: 15 % (1E-3 hPa – 1E2 hPa) | 11.25 – 75 Torr | 15 – 100 mbar
  • Accuracy of measurement in range 3: 1.25 % (full scale) (1E2 hPa – 1.2E3 hPa) | 0.94 – 900 Torr | 1.25 – 1,200 mbar
  • Ambient pressure: 790 – 1060 hPa | 592.5 – 795 Torr | 790 – 1,060 mbar
  • Ambient temperature: 5 – 60 °C | 41 – 140 °F | 278.15 – 333.15 K
  • Certification: CE, cTUVus certified according to UL / CSA 61010-1
  • Connection flange (in): G 1/8''
  • Electrical connection: B industry (micro)
  • Input voltage(s): 5 VDC (±5 %)
  • Interface - Connection, device side: Cable with (micro USB plug)
  • Materials in contact with media: Ceramic, Stainless steel, Tungsten, Silicon oxide, Glass, Araldite, Solder, Nickel
  • Measurement cable length min.: 0.5 m / 20 in
  • Measuring cycle: 100 ms
  • Measuring method: Piezo, Pirani
  • Measuring range: 5E-4 – 1.2E3 hPa | 3.75 · 10-4 – 900 Torr | 5 · 10-4 – 1,200 mbar
  • Mounting orientation: Arbitrary
  • Power consumption: 0.25 W
  • Power consumption max.: 0.25 W
  • Pressure max.: 2 · 103 hPa | 1,500 Torr | 2,000 mbar
  • Protection degree: IP40
  • Repeatability in range 1: 3 % (1E-3 hPa – 1E2 hPa) | 2.25 – 75 Torr | 3 – 100 mbar
  • Repeatability in range 2: 3 % (full scale) (1E1 hPa – 1200 hPa) | 2.25 – 900 Torr | 3 – 1,200 mbar
  • Usage: Only in indoor areas
  • Volume: 0.4 cm³
  • Weight approx.: 0.20lb

 

A&J Vacuum Services repairs / rebuilds and services all of the Pfeiffer HiScroll pumps such as the HiScroll 6 / PD S10 000, HiScroll 12 / PD S20 000, HiScroll 18 / PD S30 000, and HiScroll 46 / PD S40 000 as well as other Pfeiffer Vacuum equipment such as their turbomolecular pumps, rotary vane pumps, leak detectors, and more. Please contact us for information about our service program or click here http://www.ajvs.com/service.php to go to our service page. We also offer emergency rush service upon request. For more information please contact A&J Vacuum Services at 973-249-0854.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.