Shopping Cart ( )

Agilent RV5 with EMF 10 Filter Oil Return Line with Gas Ballast Control, G6600-60023

Condition: New
Item#:PN20566
Mfr Part#:G6600-60023
Manufacturer:Edwards Vacuum
PRICE:
$1,721.00
Web savings:
$100.00
YOU PAY:
$1,621.00
New Agilent RV5 with EMF 10 Filter Oil Return Line with Gas Ballast Control, G6600-60023
Features:
  • OEM PN G6600-60023
  • Adjustable Gas Ballast
12 months warranty

Agilent RV5 with EMF 10 Filter Oil Return Line with Gas Ballast Control, G6600-60023


 

Agilent Oil Return Line with Gas Ballast Control Features:


  • Agilent Oil Return Kit is designed to fit the following pump models:
    • RV5

Oil Return Line with Gas Ballast Control / G6600-60023 Overview:


The Gas ballast oil return kit for RV5 pump, used with series 6850, 6890, and 7890 gas chromatography systems.

Adjusable Oil Drain Kit is supplied configured so that the gas ballast flow rate is equivalent to that with the gas ballast control on the pump in position ‘II’. If required, you can adjust the gas ballast flow rate.

The Oil Drain Kit is designed for use with an RV5 pump (fitted with an EMF oil mist filter) which operates continuously with gas ballast switched on. You cannot use the Oil Drain Kit if you want to introduce a purge gas into the RV pump. If you want to introduce a purge gas into the RV pump, you must fir a Gas Ballast Adaptor to the pump (refer to the RV pump instruction manual) and oil cannot be returned from the pump.

The Agilent Clean Application Oil Return Kit G6600-60023 conserve the pump oil, by returning the oil trapped in the mist filter to the pump.

When fitted, the adjustable oil return kit returns oil trapped in the oil mistfilter back to the pump, through the gas ballast port. This Agilent Oil Return kit reduces oil loss from the pump and laso reduces the need to check the oil level in the pump.

This oil Return kit can be only used if the gases pumped do not contaminate the oil.

In normal operation, the oil level will be at or below the level of the drain adaptor on the Edwards EMF oil mist filter.

 

A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Agilent RV5 with EMF 10 Filter Oil Return Line with Gas Ballast Control, G6600-60023


 

Agilent Oil Return Line with Gas Ballast Control Features:


  • Agilent Oil Return Kit is designed to fit the following pump models:
    • RV5

Oil Return Line with Gas Ballast Control / G6600-60023 Overview:


The Gas ballast oil return kit for RV5 pump, used with series 6850, 6890, and 7890 gas chromatography systems.

Adjusable Oil Drain Kit is supplied configured so that the gas ballast flow rate is equivalent to that with the gas ballast control on the pump in position ‘II’. If required, you can adjust the gas ballast flow rate.

The Oil Drain Kit is designed for use with an RV5 pump (fitted with an EMF oil mist filter) which operates continuously with gas ballast switched on. You cannot use the Oil Drain Kit if you want to introduce a purge gas into the RV pump. If you want to introduce a purge gas into the RV pump, you must fir a Gas Ballast Adaptor to the pump (refer to the RV pump instruction manual) and oil cannot be returned from the pump.

The Agilent Clean Application Oil Return Kit G6600-60023 conserve the pump oil, by returning the oil trapped in the mist filter to the pump.

When fitted, the adjustable oil return kit returns oil trapped in the oil mistfilter back to the pump, through the gas ballast port. This Agilent Oil Return kit reduces oil loss from the pump and laso reduces the need to check the oil level in the pump.

This oil Return kit can be only used if the gases pumped do not contaminate the oil.

In normal operation, the oil level will be at or below the level of the drain adaptor on the Edwards EMF oil mist filter.

 

A&J Vacuum also repair / rebuild and service all Edwards RV3, RV5, RV8, RV12, E2M2, E2M5, E2M8, E2M12 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST