Alcatel 2012 AC Dual Stage Rotary Vane Pump

Condition: Remanufactured
Call us for Availability
Item#:PN06426
Mfr Part#:
Manufacturer:Adixen / Alcatel
Remanufactured Fully rebuilt Alcatel 2012 AC (2012AC) Dual Stage Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange
Features:
  • KF25 Inlet Flange
  • KF25 Outlet Flange
  • Peak Pumping Speed: 11cfm
  • Ultimate Pressure: 1 x 10-3 Torr.
12 months warranty

Fully rebuilt Alcatel 2012 AC (2012AC) Dual Stage Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange

 

Alcatel 2012AC Overview:


Fully refurbished Alcatel 2012 AC Dual Stage Rotary Vane Pump coupled with a KF25 Inlet Flange and KF25 Outlet Flange. This Alcatel Rotary Vane Pump has a peak pumping velocity of 11cfm and a final pressure of 1 x 10-3 Torr. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries. The Alcatel 2012 AC Pump comes with an entire 12-Month Warranty.

Unit is fully rebuilt and comes with a FULL 12-MONTH WARRANTY!

 

Alcatel 2012AC Applications:


  • Gas analysis
  • Leak detection
  • Mass spectrometers
  • Electron microscopes
  • Surface analysis
  • Centrifuges
  • Sterilization
  • Distillation
  • Metallurgy
  • Ion implantation
  • Dry etching
  • Load-lock
  • Cryogenics
  • Gas recovery
  • Oxygen pumping

A&J Vacuum Services offers full repair/service of Alcatel / Adixen Vacuum Pumps, along with all other brands offered on our website. AJVS also services Alcatel / Adixen turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Fully rebuilt Alcatel 2012 AC (2012AC) Dual Stage Rotary Vane Pump with KF25 Inlet Flange and KF25 Outlet Flange

 

Alcatel 2012AC Technical Data:


Peak Pumping Speed: 11cfm
Inlet Flange KF25
Outlet Flange KF25
Ultimate Pressure: 1 x 10-3 Torr.

 


A&J Vacuum Services offers full repair/service of Alcatel / Adixen Vacuum Pumps, along with all other brands offered on our website. AJVS also services Alcatel / Adixen turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Item#:PN01429
Mfr Part#:52625
Condition: In Stock New
In Stock
$384.00
Item#:PN09915
Mfr Part#:52574
Condition: Ships Within 1-3 Days New
$521.00
Item#:PN09941
Mfr Part#:52687
Condition: Ships Within 1-3 Days New
$204.00
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.