Shopping Cart ( )

Alcatel Adixen PFPE Lubrication Syringe, 50 ml, ABG400 Grease for Turbo Pumps, Turbomolecular Drag Pump Bearings, 2000044883 / 200031

Condition: Discontinued
Item#:PN19865
Mfr Part#:2000044883 / 200031
Manufacturer:Adixen / Alcatel
This product has been discontinued and is no longer available for sale
VIEW REPLACEMENT
Discontinued Alcatel Adixen PFPE Lubrication Syringe, 50 ml, ABG400 Grease for Turbo Pumps, Turbomolecular Drag Pump Bearings, 2000044883 / 200031
Features:
  • PFPE ABG400 Grease
  • 50 ml Syringe
  • MDP, ATP, ATS Series Turbo Pumps

Alcatel Adixen PFPE Lubrication Syringe, 50 ml, ABG400 Grease for Turbo Pumps, Turbomolecular Drag Pump Bearings, 2000044883 / 200031


 

PFPE Lubrication Syringe / 200031 Overview:


This 50 ml PFPE Syringe is used for Standard Turbo Vacuum Pump bearing maintenance, Ceramic bearings lubrication with PFPE ABG400 Grease, to maintain proper Turbo Pump operation. P/N 200031.

ABG 400 Syringe is designed for Alcatel Adixen Turbo Pump models:

  • Alcatel Adixen 5080
  • Alcatel Adixen 5081
  • Alcatel Adixen 5100
  • Alcatel Adixen 5101
  • Alcatel Adixen MDP 5010
  • Alcatel Adixen MDP 5011
  • Alcatel Adixen Drytel 30
  • Alcatel Adixen Drytel 31
  • Alcatel Adixen Drytel 100
  • Alcatel Adixen Drytel 1025
  • Danielson TD 20
  • Danielson TD 30/16
  • Danielson TD 100/16
  • Danielson TD 200/16
  • Alcatel Adixen ATH 200
  • Alcatel Adixen ATP 80
  • Alcatel Adixen ATP 100
  • Alcatel Adixen ATP 150
  • Alcatel Adixen ATP 400
  • Alcatel Adixen ATP 900
  • Alcatel Adixen ATP 900 C
  • Alcatel 5030
  • Alcatel Adixen ATS 100
This item is non-returnable/non-refundable

Alcatel Adixen PFPE Lubrication Syringe, 50 ml, ABG400 Grease for Turbo Pumps, Turbomolecular Drag Pump Bearings, 2000044883 / 200031


 

PFPE Lubrication Syringe / 200031 Overview:


This 50 ml PFPE Syringe is used for Standard Turbo Vacuum Pump bearing maintenance, Ceramic bearings lubrication with PFPE ABG400 Grease, to maintain proper Turbo Pump operation. P/N 200031.

ABG 400 Syringe is designed for Alcatel Adixen Turbo Pump models:

  • Alcatel Adixen 5080
  • Alcatel Adixen 5081
  • Alcatel Adixen 5100
  • Alcatel Adixen 5101
  • Alcatel Adixen MDP 5010
  • Alcatel Adixen MDP 5011
  • Alcatel Adixen Drytel 30
  • Alcatel Adixen Drytel 31
  • Alcatel Adixen Drytel 100
  • Alcatel Adixen Drytel 1025
  • Danielson TD 20
  • Danielson TD 30/16
  • Danielson TD 100/16
  • Danielson TD 200/16
  • Alcatel Adixen ATH 200
  • Alcatel Adixen ATP 80
  • Alcatel Adixen ATP 100
  • Alcatel Adixen ATP 150
  • Alcatel Adixen ATP 400
  • Alcatel Adixen ATP 900
  • Alcatel Adixen ATP 900 C
  • Alcatel 5030
  • Alcatel Adixen ATS 100
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.