Remanufactured Edwards AGC Active Gauge Controller Triple Display, D38660000, EDWARDS AGC D3866
Features:
  • D38660000
  • Temperature range operating: 0 C to 40 C
  • Maximum operating altitude 2000m
  • Enclosure rating IP205
12 months warranty

Edwards AGC Active Gauge Controller Triple Display, D38660000, EDWARDS AGC D3866

 

Edwards AGC Overview:


The Edwards Active Gauge Controller (AGC) is used with the Edwards Active vacuum gauges. The AGC interfaces directly to 3 or 6 (depending on the AGC model) Active vacuum gauges providing a comprehensive control and display system.

You can use any of the following gauges with the AGC D38660000:

  • Active Pirani APG-M, APG-L
  • Active Inverted Magnetron AIM-S, AIM-X
  • Active Thermocouple ATC-M, ATC-D with ATC-E
  • Active Ion Gauge IGC-I2R, IGC-EBEAM, AIGX
  • Active Strain Gauge ASG
  • Wide Range Gauge WRG
  • Active Linear Pirani APGX
  • Linear Convection Gauge APGX-H

Gauges can be turned on and off manually from the front panel or can be programmed to switch on automatically when the pressure measured by another gauge reaches a pre-set level.

The display and control features of the AGC are accessed through a menu structure. You move through the menu with simple keystroke combinations entered from the front panel. Security of gauge settings is achieved by a two level password system which restricts access to certain areas of the menu. In addition, the AGC can be interfaced to other microprocessor and data acquisition systems through an optional serial RS232 communications link.

The AGC Controller has 6 outputs which can be programmed as gauge pressure set points and so used to control the operation of auxiliary equipment. An optional relay board can be fitted which increases the load capability of these outputs.

The AGC Controller has one chart recorder output for each gauge channel (3 or 6 depending on version). These give an analogue output in the range 0 to 10 V corresponding to the pressure measured by the gauge.


THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

Edwards AGC Dimensions:


Edwards AGC D38660000, Dimensions


Click Here for Edwards AGC Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Edwards AGC Active Gauge Controller Triple Display, D38660000, EDWARDS AGC D3866

 

Edwards AGC Technical Data:


Temperature range operating: 0 C to 40 C
Temperature range storage: -20 C to 70 C
Relative humidity (non-condensing) operating and storage: 10% to 90%
Maximum operating altitude 2000m
Installation category - IEC1010 1
Pollution category - IEC1010 2
Enclosure rating IP205
Input voltage range: 90 - 265 V a.c.(rms)
Input frequency range: 45 - 70 Hz
Power consumpiotn: 50 W
Fuse rating:  2 A (Type T, slow blow)
Mass 5.5 kg

Click Here for Edwards AGC Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.