- Inlet flange: DN 100 CF-F
- Pumping speed : 260 l/s
- Ultimate pressure: < 1 x 10-7mbar
- Backing Pump Pumping Speed 1 m3/h
The Pfeiffer Vacuum HiCube300 Eco Turbo Pumping Station is the trully portable and bench top pumping unit for many of the High Vacuum Applications. Also available with CF-F Inlet Flangethat makes this system trully Ultra High Vacuum (UHV).
The Hicube 300 Station has a modern design with the latest turbo pump and electronics technology.
What’s so special about the HiCube vacuum solution: The combination of a turbopump from the HiPace series and a backing pump designed for the user’s specific application needs. We offer you the HiCube in Pro and Classic versions; available with dry compressing or oil-sealed backing pump and an ultimate pressure of up to 5 · 10-10 hPa.
The HiCube Eco turbo pumping station is distinguished by its modular construction. Thanks to the many possibilities of combining different turbopumps and backing pumps, the HiCube Eco can be configured to meet the requirements of all applications in high and ultra-high vacuums. In addition, all HiCube Eco pumping stations feature connectivity for digital pressure sensors.
All HiCube Eco turbo pumping stations are fitted with particularly energy-efficient backing pumps that have a DC drive. The turbopump and the backing pump form a single unit in the pumping station. If there is no gas load in the vacuum, the pumping station automatically reduces the backing pump output. This results in maximum energy savings.
A&J Vacuum also repair / rebuild and service all Pfeiffer HICUBE 300 ECO Pumping Stations PM S77 100 00, Pfeiffer Turbo Pumps along with all other Pfeiffer Vacuum Rotary Vane Pumps, Pfeiffer Dry Pumps, Pfeiffer Leak Detector Repair and all other Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
| Backing pump | MVP 015-2 |
| Cooling method, standard | Air |
| Flange (in) | DN 100 CF-F |
| Flange (out) | Silencer, G 1/8" |
| Mains connection: Voltage | 100 – 240 V |
| Mains requirement | 110 – 240 V AC, 50/60 Hz |
| Mains requirement: frequency (range) | 50/60 Hz |
| Mains requirement: power consumption | 270 W |
| Power consumption max. | 270 W |
| Pumping speed backing pump at 50 Hz | 1 m³/h | 0.59 cfm | 16.67 l/min |
| Pumping speed for N2 | 260 l/s |
| Sound pressure level | ≤50 dB(A) |
| Turbopump | HiPace 300 |
| Type | Turbo pumping station |
| Ultimate pressure | < 1 · 10-8 hPa | < 7.5 · 10-9 Torr | < 1 · 10-8 mbar |
| Ultimate pressure without gas ballast | < 1 · 10-8 hPa | < 7.5 · 10-9 Torr | < 1 · 10-8 mbar |
| Weight | 17.9 kg | 39.46 lb |
| Pumping speed | 1 m³/h | 0.59 cfm | 16.67 l/min |
| Ultimate pressure with gas ballast | ≤ 6 hPa | ≤ 4.5 Torr | ≤ 6 mbar |
| Ultimate pressure without gas ballast | ≤ 3.5 hPa | ≤ 2.62 Torr | ≤ 3.5 mbar |
| Flange (in) | G 1/8" |
| Number of pumping stages | 2 |
| Flange (out) | G 1/8" with silencer |
| Motor version | DC motor |
| Voltage: Range | ± 10 % |
| Current max. | 4,6 A |
| Rated current absorption | 2.9 A |
| Short circuit current of power supply, max. | 45 A |
| Protection category | IP20 |
| Operating altitude, max. | 2000 m |
| Rotation speed | 540-2,600 rpm | 540-2,600 min-1 |
| Cooling method, standard | Convection cooled |
| Ambient temperature | 5-40 °C | 41-104 °F | 278-313 K |
| Temperature: Storage | 5-40 °C | 41-104 °F | 278-313 K |
| Intake pressure max. | 1,100 hPa | 825 Torr | 1,100 mbar |
| Exhaust pressure, max. | 1,100 hPa | 825 Torr | 1,100 mbar |
| I/O interfaces | RS-485 |
| Sound pressure level | 50 dB(A) |
| Switch | No |
| Mains cable | No |
| Gas ballast | Yes |
| Leak rate | ≤ 5 · 10-4 Pa m3/s | ≤ 3.75 · 10-3 Torr l/s | ≤ 5 · 10-3 mbar l/s |
| Weight | 2.7 kg | 5.95 lb |
A&J Vacuum also repair / rebuild and service all Pfeiffer HICUBE 300 ECO Pumping Stations PM S76 100 00, Pfeiffer Turbo Pumps along with all other Pfeiffer Vacuum Rotary Vane Pumps, Pfeiffer Dry Pumps, Pfeiffer Leak Detector Repair and all other Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
We can have a repair estimate ready for your equipment within the hour of submission.
Start your equipment repair process by creating a Service RMA.
A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.
We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.