Shopping Cart ( )

Leybold / Oerlikon D 40 BCS Dual Stage Rotary Vane Vacuum Pump, CFS Filtration Module Installed, PFPE Fluid

Condition: Remanufactured
Call us for Availability
Item#:PN06681
Mfr Part#:
Manufacturer:Leybold
Remanufactured Leybold / Oerlikon D 40 BCS Dual Stage Rotary Vane Vacuum Pump, CFS Filtration Module Installed, PFPE Fluid
Features:
  • Pumping Speed: 32.5 cfm
  • KF 40
  • Ultimate Pressure: 1.5 x 10-3 Torr
  • IP 55 Protection
12 months warranty

Leybold / Oerlikon D 40 BCS Dual Stage Rotary Vane Vacuum Pump, CFS Filtration Module Installed, PFPE Fluid


 

Leybold D 40 BCS Features:


  • Peak Pumping Speed: 32.5 cfm
  • KF40 Inlet Flange
  • KF40 Outlet Flange
  • Ultimate Pressure: 1.5 x 10-3 Torr
  • This pump is fully rebuilt and comes with a FULL 12-MONTH WARRANTY!

 

D 40 BCS / Overview:


Fully refurbished Leybold / Oerlikon D40BCS PFPE Dual Stage Rotary Vane Pump coupled with a KF40 Inlet Flange and KF40 Outlet Flange. This Leybold / Oerlikon Rotary Vane Pump has a peak pumping velocity of 32.5 cfm and a final pressure of 1.5 x 10-3 Torr. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries. The Leybold / Oerlikon D40BCS PFPE Pump comes with an entire 12-Month Warranty.

A rotary vane pump can be described as a positive-displacement pump that is comprised of vanes mounted to a rotor that rotates inside of an enclosure. In some instances these vanes can be of varying length and tensioned to maintain contact with the walls as the pump rotates.

The simplest rotary vane pump is a circular rotor revolving inside of a larger round enclosure. The centers of these two bands are offset, inducing eccentricity. Vanes are allowed to slide in and out of the rotor and seal on all edges, making vane chambers that do the pumping work. On the intake side of the pump, the vane chambers are increasing in volume. These increasing volume vane chambers are filled with fluid forced in by the inlet pressure. Inlet pressure level is actually the pressure level from the system being pumped, frequently just the atmosphere. On the exhaust side of the pump, the vane chambers are decreasing in volume, forcing fluid out of the pump. The activity of the vane drives out the same volume of fluid with each rotation. Multistage rotary vane vacuum pumps can reach pressures levels as low as 103 mbar (0.1 Pa).Visit the rotary vane pump wiki page for more information.

 

D40BCS Applications:


  • Gas analyzers
  • Leak detection
  • Mass spectrometers
  • Other spectrometers
  • Electron microscopes
  • Surface analyzers
  • Centrifuges
  • Sterilization
  • Electron tubes
  • Lamps
  • TV tubes (CRT)
  • Refrigeration
  • Air conditioning
  • Drying
  • Distillation
  • Metallurgy
  • Free drying
  • CVD.LPCVD
  • Ion implantation
  • Dry etching
  • Load-lock
  • Cryogenics
  • Gas recovery
  • Oxygen pumping

 

A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versionsof Trivac D8B vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Leybold / Oerlikon D 40 BCS Dual Stage Rotary Vane Vacuum Pump, CFS Filtration Module Installed, PFPE Fluid

 

Leybold D 40 BCS Technical Data:

Nominal pumping speed (50Hz | 60Hz) 46 m3/h (27 cfm) 55 m3/h (32.5 cfm)
Pumping speed (50Hz | 60Hz) 40 m3/h (24 cfm) 48 m3/h (28 cfm)
Ultimate partial pressure without gas ballast (50Hz | 60Hz) 10-4 mbar (0.75 x 10-4 Torr) 10-4 mbar (0.75 x 10-4 Torr)
Ultimate total pressure without gas ballast (50Hz | 60Hz) < 2 x 10-3 mbar (< 1.5 x 10-3 Torr) < 2 x 10-3 mbar (< 1.5 x 10-3 Torr)
Ultimate total pressure with gas ballast (50Hz | 60Hz) < 5 x 10-3 mbar (< 3.8 x 10-3 Torr) < 5 x 10-3 mbar (< 3.8 x 10-3 Torr)
Water vapor tolerance (50Hz | 60Hz) 40 mbar (30 Torr) 40 mbar (30 Torr)
Water vapor capacity (50Hz | 60Hz) 1184 g/h (2.610 lbs/h) 1420 g/h (3.131 lbs/h)
Oil filling, min. / max. (50Hz | 60Hz) 1.7 / 2.6 l (1.8 / 2.7 qt) 1.7 / 2.6 l (1.8 / 2.7 qt)

Noise level to DIN 45 635, without / with gas ballast (50Hz | 60Hz)

57 / 59 dB(A) 57 / 59 dB(A)
Admissible ambient temperature (50Hz | 60Hz) +12 to +40 °C (+54 to +104 °F) +12 to +40 °C (+54 to +104 °F)
Motor rating (50Hz | 60Hz) 2200 W (3.0 HP) 2200 W (3.0 HP)
Nominal speed (50Hz | 60Hz) 1460 rpm 1760 rpm
Type of protection (50Hz | 60Hz) IP 55 IP 55
Connections, Intake and Exhaust (50Hz | 60Hz) 40 KF 40 KF
Weight (50Hz | 60Hz) 75.3 kg (166 lbs) 75.3 kg (166 lbs)

 

A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versionsof Trivac D8B vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.