Shopping Cart ( )

Edwards E2M18 Vacuum Pump 208 VAC 60 Hz, Single Phase, 100-105 / 200-210 VAC, Agilent NRA5-01-000 / NRA501000

Condition:
In Stock
Item#:PN40993
Mfr Part#:NRA5-01-000 / NRA501000
Manufacturer:Edwards Vacuum
PRICE:
$4,900.00
Web savings:
$1,450.00
YOU PAY:
$3,450.00
Edwards E2M18 Vacuum Pump 208 VAC 60 Hz, Single Phase, 100-105 / 200-210 VAC, Agilent NRA5-01-000 / NRA501000
Features:
  • Agilent NRA5-01-000 / NRA501000
  • Fully Rebuilt
  • 100-105 VAC 60 Hz, 200-210 VAC 60 Hz, Single Phase
  • Set to 208 VAC - Hydrocarbon oil service
12 months warranty

Fuly Rebuilt Edwards E2M18 Vacuum Pump 208 VAC 60 Hz, Single Phase, 100-105 / 200-210 VAC, Agilent NRA5-01-000 / NRA501000

 

Edwards E2M18 Agilent NRA5-01-000


The Edwards E2M18 / NRA0510000 vacuum pumps are direct drive, sliding vane pumps. The E2M18 is a dual-stage vaccuum pump.

The Edwards E2M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards Agilent 208 V E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Agilent Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fuly Rebuilt Edwards E2M18 Vacuum Pump 208 VAC 60 Hz, Single Phase, 100-105 / 200-210 VAC, Agilent NRA5-01-000 / NRA501000

 

Edwards E2M18 Agilent NRA5-01-000 Technical Data:


Displacement (swept volume)
    50 Hz 20.5 m3h-1 / 12.1 ft3min-1
    60 Hz 25.0 m3h-1 / 14.7 ft3min-1
Speed (Pneurop 6602)
    50 Hz 17.0 m3h-1 / 10 ft3min-1
    60 Hz 20.4 m3h-1 / 12.1 ft3min-1
Ultimate vacuum (total pressure)
    without gas purge 3 x 10-2 mbar / 2.2 x 10-2 Torr
    with gas purge 6.5 x 10-1 mbar / 4.8 x 10-1 Torr
Inlet connection NW25
Outlet connection Nozzle 15 mm external diameter removable from 3/4" BSP tapped hole
Maximum permitted pressure at outlet 0.5 bar gauge / 7 psig
Maximum inlet pressure for water vapour     50 mbar / 38 Torr
Maximum water vapour pumping rate 0.65 kg h-1
Motor power 50/60 Hz 0.55 kW / 0.75kW
Nominal rotational speed 50/60Hz 1,440/1,720 rpm
Power connector IEC EN60320 C19
Operating temperature range 13 - 40°C
Weight 37 kg / 82 lbs
Noise 57 dB(A) @ 50 Hz
Oil capacity - maximum 1.4 litre
Oil capacity - minimum 0.9 litre
Recommended oil Ultragrade 19

Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Item#:PN07103
Mfr Part#:34301820
Condition: In Stock New
In Stock
$137.00
Item#:PN07275
Mfr Part#:36301131
Condition: In Stock New
In Stock
$171.00
Item#:PN10941
Mfr Part#:26401747
Condition: Out of Stock New
$430.00
Item#:PN11079
Mfr Part#:34301041ED
Condition: In Stock New
In Stock
$188.00
Item#:PN14500
Mfr Part#:MA0005RO_100V_50_60Hz
Condition: In Stock New
In Stock
$334.99
Item#:PN15494
Mfr Part#:H11025013
Condition: In Stock New
In Stock
$185.00
Item#:PN00844
Mfr Part#:A46229000
Condition: In Stock New
In Stock
$749.99
Item#:PN07053
Mfr Part#:A50420000
Condition: In Stock New
In Stock
$438.00
Item#:PN07559
Mfr Part#:KF25CLA
Condition: In Stock New
In Stock
$10.25
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.