Shopping Cart ( )

Adixen ASM 182 T Helium Leak Detector, 4.4 l/s Pumping Speed, 200/240 VAC / 50/60Hz, US Power Cable, D20RT0B817

Condition: Remanufactured
Call us for Availability
Item#:PN24124
Mfr Part#:D20RT0B817
Manufacturer:Pfeiffer Vacuum
Remanufactured Adixen ASM 182 T Helium Leak Detector, 4.4 l/s Pumping Speed, 200/240 VAC / 50/60Hz, US Power Cable, D20RT0B817
Features:
  • Unmatched Inlet Port Pumping Speed of 4.4 Liters/SECOND
  • Includes a High-Resolution 180-Degree Mass Spectrometer
  • Capacity to Test Volumes of up to 250 Liters Without External Pumping
  • Utilizes a DN 40 ISO-KF Inlet Flange Model (Utilizing a 40 mm Diameter)
6 months warranty

Refurbished Adixen ASM 182 T Helium Leak Detector, 4.4 l/s Pumping Speed, 200 / 240 VAC / 50/60Hz, US Power Cable, D20RT0B817

 

Pfeiffer/Adixen ASM 182T Helium Leak Detector Overview:


The refurbished Pfeiffer Adixen ASM 182 T is a fully-automatic, multi-purpose helium leak detector. The ASM 182 T system incorporates a 130 L/S hybrid turbomolecular high vacuum pump, with an integrated 16 CFM two-stage rotary vane roughing/backing pump.The Pfeiffer Adixen ASM 182 T leak detector is ideally suited for operations requiring continuously high performance operation and production usage rates.

 

Outstanding Features and Benefits of the ASM182T Helium Leak Detector Include:


  • High sensitivity of 5 * 10^[-12] atm. cc/sec. helium (according to AVS 2.1 and ISO 3530 standards) at full pumping speed.

  • Unmatched inlet port helium pumping speed of 4.4 liters per second for quick response and clean-up time, allowing the ASM 182 T to outperform competing helium leak detectors with regard to pump velocity and overall efficiency.

  • High inlet port test pressure of up to 6 mbar (4500 microns) in full contraflow configuration for maximum performance results.

  • A high-resolution 180-degree deflection mass spectrometer with VHS preamplifier (multi-channel electron multiplier) for added sensitivity, stability, and durability.

  • Capacity to test large volumes of up to 250 liters without the need to utilize external pumping to increase sensitivity, giving the ASM 182 T a significant advantage over previous leak detectors in flow capacity and pump velocity.

  • Automated dual vacuum test schematics of gross leak contraflow and fine leak direct flow used for extended-range testing.

  • Auto-calibration utilizing an internal helium-calibrated leak with temperature, as well as percentage loss compensation for extended accuracy and simplified operation.

  • High roughing capacity of 16 CFM with an incorporated two-stage rotary vane pump for large-volume evacuation and rapid production cycles.

  • Simplified start-up and shut-down process featuring a single button; shut down can be executed regardless of mode of operation, accompanied by a selectable user interface for user-friendly operation.

  • Standard extended-interface capability which includes: 5 dry-contact outputs, 6 inputs, analog leak rate output, and comprehensive RS232 interface. The Adixen ASM 182 T System, alongh with other, similar Adixen helium leak detectors, is fully protected against power failure, errors resulting from movement during operation,and air penetration resulting in compromised operations. Additionally, access to the 24-hour extended support program (ESP) is likewise included for the Pfeiffer Adixen ASM 182 T helium leak detector.

 

Pfeiffer/Adixen ASM 310 Control panel:


Pfeiffer/Adixen ASM 182 T Front panel, D20RT00PB710

 

 

A Brief Description of the Science and Processes Involved in Helium Leak Detection:


Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.

Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.

 

Pfeiffer/Adixen ASM182T Dimensions:


Pfeiffer/Adixen ASM 182T, D20RT00PB710


Click Here for Pfeiffer/Adixen ASM 182 T Manual


A&J Vacuum Services offers full repair/service of Pfeiffer ASM 182 T Helium Leak Detectors, along with all other varieties of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Refurbished Adixen ASM 182 T Helium Leak Detector, 4.4 l/s Pumping Speed, 200 /2 40 VAC / 50/60Hz, US Power Cable, D20RT0B817

 

Pfeiffer/Adixen ASM 182T Technical Data:


Backing Pump Oil Sealed Backing Pump
Backing Pump Capacity 20 m³/h | 11.77 cfm | 333.33 l/min
Detectable Gases 4He
Dimensions (L x W x H) 594 x 434 x 444 mm | 23.39 x 17.09 x 17.48 inch
Flange Model (Inlet) DN 40 ISO-KF
I/O interfaces Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure)
Language English
Mains Cable Yes, US power cable  
Minimum Detectable Leak Rate for Helium (Sniffing Leak Detection) 1 * 10^[-8] Pa m^3/s | 7.5 * 10^[-8] Torr l/s | 1 * 10^[-7] mbar l/s
Minimum Detectable Leak Rate for Helium (Vacuum Leak Detection) 5 * 10^[-13] Pa m³/s  
Noise Level 54 dB(A)
Operating Temperature 10 – 40 °C
Power Consumption 1000 W
Pumping Dpeed For He 4.4 l/s
Sound Pressure Level 54 dB(A)
Start-Up Time (20°C) With Calibration 4.5 min
Start-Up Time (20°C) Without Calibration 3 min
Supply 200 / 240 VAC, 50/60 Hz
Test Method Vacuum and Sniffing Leak Detection
Type High Performance - Compact
User Interface Graphic Color Touch Screen
Weight 76 kg | 167.55 lb

Click Here for Pfeiffer/Adixen ASM 182 T Manual


A&J Vacuum Services offers full repair/service of Pfeiffer ASM 182 T Helium Leak Detectors, along with all other varieties of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Item#:PN07560
Mfr Part#:KF40CLA
Condition: In Stock New
In Stock
$18.99
Item#:PN17212
Mfr Part#:112535/112535
Condition: In Stock New
In Stock
$735.00
Item#:PN17213
Mfr Part#:2000046756 / 109951
Condition: In Stock New
In Stock
$1,170.00
$1,095.00
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.