New Edwards XDS 46i Dry Scroll Vacuum Pump, 100-120 V / 200-230 V, Single Phase, 50/60 Hz, A73101983 / A731-01-983
Features:
  • Pumping Speed 20.6 CFM
  • Ultimate Vacuum: 1 x 10-2 mbar / 8 x 10-3 Torr
  • Inlet Flange: NW 40
  • Exhaust Flange: NW 25
12 months warranty

Edwards XDS 46i Dry Scroll Vacuum Pump, 100-120 V / 200-230 V, Single Phase, 50/60 Hz, A73101983 / A731-01-983


 

Edwards XDS 36i Features:


  • Lubricant-free within the vacuum envelope and hermetically sealed means totally clean and dry vacuum to prevent cross contamination
  • No atmosphere to vacuum shaft seals means bearing are completely isolated, which prevents process attack and means the bearings run cooler and last longer
  • Simple single sided scroll design means routine maintenance is done in minutes for low cost of ownership and maximum up-time
  • No oil changes required eliminating costs of contaminated oil disposal
  • Inverter drive for consistent pumping speed at 50/60 Hz

XDS 46i / A73101983 Overview:


The Edwards XDS46i pump has an innovative bearing shield design that isolates the vacuum environment from all forms of lubricant, not only making it totally dry but hermetically sealed.

The Edwards XDS-46i shield also protects the bearing from any process vapors. nXDS 35i gas ballast allows vapor to be handled and opens up the range of applications to many that were previously unsuited to scroll pumps. The inverter drive controls the motor characteristics and ensures the pump always runs at optimum speed.

Edwards XDS46i pumps also feature the latest in tip seal technology giving significantly longer life between tip seal changes. Integrated inverter drive with auto sensing voltage input delivers optimized pumping performance globally.  Edwards nXDS35i pumps are designed to be completely field serviceable.

 

A&J Vacuum also repair / rebuild and service all Edwards XDS5, XDS10, nXDS46i Scroll Vacuum Pumps  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Edwards XDS 46i Dry Scroll Vacuum Pump, 100-120 V / 200-230 V, Single Phase, 50/60 Hz, A73101983 / A731-01-983

 

Edwards XDS 46i Technical Data:

Connection Inlet Flange DN 40 ISO-KF (NW40)
Weight 48.00 kg | 106 lb
Connection Outlet Flange DN 25 ISO-KF (NW25)
Leak Rate 1.000 × 10⁻⁷ Pa·m³/s
Power Supply Phase 1-Ph
Power Supply Voltage 1Ph 100-120/200-230V 50/60Hz
Dimension Length 476.00 mm | 18.74 in
IP Rating IP44
Power Supply Frequency 50 Hz
60 Hz
Dimension Height 396.00 mm | 15.59 in
Dimension Width 333.00 mm | 13.11 in
Connector Electrical Power IEC EN60320 C20 - Male (for C19 plug on mains cable)
Noise / Sound Level 55.40 db(A)
Cooling Method Air Cooling (forced - fan)
Vibration Level Velocity (rms) 4.500 × 10⁻³ m/s
Certification of Product CE
UL (61010-1 3rd Edition)
CSA (C22.2 No.61010-1-12)
Connection Inlet / Outlet Flange DN 40 ISO-KF (NW40) / DN 25 ISO-KF (NW25)
Accessories / Scope of Supply This product does not include the correct local mains power cable. Has to be additionally selected from the list of suitable accessories.
Certification Motor UL (61010-1 3rd Edition)
CSA (C22.2 No.61010-1-12)
Power Total Rated 550.00 W
Pumping Speed Air Nitrogen 60Hz 0.011 m³/s
Pumping Speed Air Nitrogen 50Hz 0.011 m³/s
Pressure Water Vapour Max 4000.00 Pa
Capacity Water Vapour 6.667 × 10⁻⁵ kg/s
Pressure Ultimate With Gas Ballast 1000.00 Pa
Pressure Ultimate 5.00 Pa
Nominal rotational speed 29.17 Hz
Power at Ultimate 380.00 W
Pumping Speed Air Nitrogen 0.011 m³/s
Power at Ultimate With Gas Ballast 47500.00 W
Power at Atmosphere Short Term Max 2300.00 W
Pressure Absolute Inlet Continous Max 4000.00 Pa
Altitude Max 78740.16 in
Pressure Absolute Outlet Continous Max 1.200 × 10⁵ Pa
Temperature Ambient Operation Max 40.00 °C | 104.00 °F | 313.15 K
Temperature Ambient Operation Min 10.00 °C | 50.00 °F | 283.15 K
Temperature Ambient Storage Min -30.00 °C | -22.00 °F | 243.15 K
Temperature Ambient Storage Max 70.00 °C | 158.00 °F | 343.15 K
Material of Construction Fluorocarbon,nitrile,chemically resistant polymers,nickel,stainless steel and PTFE
Material Exposed to Vacuum Anodised aluminium, cast aluminium, nickel, PTFE, Stainless Steel, fluorocarbon elastomer seals, chemically resistant polymers
Material Rotor Aluminum Anodised
Material Stator Aluminum Anodised
Classification Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Classification High / Medium / Rough Vacuum pump Rough Vacuum Pump
Classification Dry or Wet Pump Dry
Classification Vacuum Pump Technology Dry Scroll Pump
Communication Interfaces Customer Parallel I/O
Display local (hours counter)
Connection Electrical Comms Interface Connector DSUB 15-PIN - Female
Variant Scroll Pump Standard variant
Variant Atex Category Ex II 3 G Ex h IIB T4 Gc - internal atmospheres only

A&J Vacuum also repair / rebuild and service all Edwards XDS5, XDS10, nXDS35i Scroll Vacuum Pumps  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST