phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006
Item#: PN31551 Mfr Part#: 800002V3006 Manufacturer: Leybold
Condition:
New
New Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006

Features:
  • Brand New
  • P/N 800002V3006
  • DN 63 ISO-K
  • Leybold

PRICE: $9,144.00
WEB SAVINGS: $769.00
YOU PAY: $8,375.00
Tariff charges are calculated during checkout
Item#: PN31551 Mfr Part#: 800002V3006
Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006
Item#: PN31551 Mfr Part#: 800002V3006 Manufacturer: Leybold 12 months warranty

Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006


 

Leybold Turbovac SL 80 H Features:


  • Ultimate pressure: < 2.0 x 10-10 mbar
  • Pumping speed (Ar): 60 l/s
  • Pumping speed (He): 55 l/s
  • Pumping speed (H₂): 49 l/s
  • Pumping speed (N₂): 65 l/s
  • Stress free operation
  • High performance
  • High foreline tolerance

 

Turbovac SL 80 H / 800002V3006 Overview:


The pumps SL 80 comprise essentially the pump housing, a multi-stage rotor with the stator group, and the drive.

The first section of the rotor is a turbomolecular pump rotor while the second tile represents a Holweck stage. The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classic turbomolecular pump. The rotor shaft runs in two lifetime lubricated ceramic ball bearings.

The pump is driven by a split-cage DC motor. In this motor the rotor and stator windings are separated by a vacuum-tight can. Consequently the rotor runs inside the vacuum while the stator is outside the vacuum. This eliminates any need of vacuum feedthroughs. The pump is equipped with a temperature sensor and a resistor code.

Water cooling or an air cooling fan is available as optional equipment. The intake flange should be fitted with a wire mesh inlet screen to protect the pump against mechanical damage caused by foreign objects.

The pump is driven by an electronic frequency converter TURBO.DRIVE. All functions like, for example, speed control, pump sensing or temperature monitoring are monitored by the TURBO.DRIVE. This unit is powered by an external power supply. The drive may be installed beside or underneath the pump or up to 5 m away. The pumps are equipped with a purge gas facility.

The purge gas and venting connection is blanked off by default with a M8 closure screw. A purge gas and venting valve may be connected either directly or by using a M8 – DN16KF adapter. For space reasons, when the frequency converter is installed at the side, only either the air cooler or a purge gas valve can be connected.

 

TurbovacSL80H Applications:


  • Analytical technologies / Research & Development
    • Mass spectrometers
    • Electron microscopes
    • Surface analysis
    • X-ray-analysis
    • Particle accelerators and synchrotons
    • Laboratory coating systems
    • MBE (Molecular Beam Epitaxy)
    • UHV systems
  • Life Sciences
    • Proton therapy
    • Gamma sterilisation
    • Production of high quality implants
  • Industrial and Coating applications
    • PVD- Physical Vapour deposition
    • Optical coatings
    • CD/DVD/Bly-Ray Disc production
    • Thin film technologies, photovoltaics
    • Wear protection
    • Heat treatment
    • Electron beam welders
  • Load locks, transfer chambers, handling systems
  • Insulation vacuum and leak detection

 

A&J Vacuum repair / rebuild and service all Leybold SL80 800002V3006 Turbo Pumps, Oerlikon SL 80 800002V3001 Pumps Leybold TMP Turbo Pump Service, Sogevac Pump Repair, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006

 

Leybold Turbovac SL 80 H Technical Data:

  • Inlet connection: DN 63 CF
  • Outlet connection: DN 16 ISO-KF
  • Pumping speed:
    • N2 - Nitrogen: 65 l/s
    • Ar - Argon: 60 l/s
    • He - Helium: 55 l/s
    • H2 - Hydrogen: 49 l/s
  • Gas throughput:
    • N2 - Nitrogen: 0.9 mbar x l/s
    • Ar - Argon: 0.8 mbar x l/s
    • He - Helium: 1.5 mbar x l/s
    • H2 - Hydrogen: 0.6 mbar x l/s
  • Compession ratio:
    • N2 - Nitrogen: > 1.0 x 10^11
    • Ar - Argon: > 1.0 x 10^11
    • He - Helium: 6.0 x 10^6
    • H2 - Hydrogen: 8.0 x 10^4
  • Ultimate pressure: < 2.0 x 10-10 mbar | < 1.5 x 10-10 Torr
  • Max. foreline pressure for N2: 16.0 mbar | 12.0 Torr
  • Nominal rotation speed: 72000 min-1 | 72000 rpm
  • Rotational speed adaptation: 62 - 100 %
  • Run-up time: ≈ 1.5 min
  • Max. power consumption: 120 W
  • Power consumption at ultimate pressure: 17 W
  • Protection rating: IP 20
  • Admissible ambient temperature: +5 to +45 °C | +41 to +113 °F
  • Standard cooling: Convection
  • Optional cooling: Air / Water
  • Cooling water connection: G 1/8", Inside thread / 8 mm nose nozzle
  • Cooling water consumption: 15 - 60 l/h
  • Permissible cooling water pressure: 2 - 7 bar
  • Permissible cooling water temperature: +10 to +40 °C | +50 to +113 °F
  • Weight: ≈ 1.9 kg | ≈ 4.2 lbs

 

A&J Vacuum repair / rebuild and service all Leybold SL80 800002V3006 Turbo Pumps, Oerlikon SL 80 800002V3001 Pumps Leybold TMP Turbo Pump Service, Sogevac Pump Repair, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006
Item#: PN31551 Mfr Part#: 800002V3006 Manufacturer: Leybold

Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006


 

Leybold Turbovac SL 80 H Features:


  • Ultimate pressure: < 2.0 x 10-10 mbar
  • Pumping speed (Ar): 60 l/s
  • Pumping speed (He): 55 l/s
  • Pumping speed (H₂): 49 l/s
  • Pumping speed (N₂): 65 l/s
  • Stress free operation
  • High performance
  • High foreline tolerance

 

Turbovac SL 80 H / 800002V3006 Overview:


The pumps SL 80 comprise essentially the pump housing, a multi-stage rotor with the stator group, and the drive.

The first section of the rotor is a turbomolecular pump rotor while the second tile represents a Holweck stage. The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classic turbomolecular pump. The rotor shaft runs in two lifetime lubricated ceramic ball bearings.

The pump is driven by a split-cage DC motor. In this motor the rotor and stator windings are separated by a vacuum-tight can. Consequently the rotor runs inside the vacuum while the stator is outside the vacuum. This eliminates any need of vacuum feedthroughs. The pump is equipped with a temperature sensor and a resistor code.

Water cooling or an air cooling fan is available as optional equipment. The intake flange should be fitted with a wire mesh inlet screen to protect the pump against mechanical damage caused by foreign objects.

The pump is driven by an electronic frequency converter TURBO.DRIVE. All functions like, for example, speed control, pump sensing or temperature monitoring are monitored by the TURBO.DRIVE. This unit is powered by an external power supply. The drive may be installed beside or underneath the pump or up to 5 m away. The pumps are equipped with a purge gas facility.

The purge gas and venting connection is blanked off by default with a M8 closure screw. A purge gas and venting valve may be connected either directly or by using a M8 – DN16KF adapter. For space reasons, when the frequency converter is installed at the side, only either the air cooler or a purge gas valve can be connected.

 

TurbovacSL80H Applications:


  • Analytical technologies / Research & Development
    • Mass spectrometers
    • Electron microscopes
    • Surface analysis
    • X-ray-analysis
    • Particle accelerators and synchrotons
    • Laboratory coating systems
    • MBE (Molecular Beam Epitaxy)
    • UHV systems
  • Life Sciences
    • Proton therapy
    • Gamma sterilisation
    • Production of high quality implants
  • Industrial and Coating applications
    • PVD- Physical Vapour deposition
    • Optical coatings
    • CD/DVD/Bly-Ray Disc production
    • Thin film technologies, photovoltaics
    • Wear protection
    • Heat treatment
    • Electron beam welders
  • Load locks, transfer chambers, handling systems
  • Insulation vacuum and leak detection

 

A&J Vacuum repair / rebuild and service all Leybold SL80 800002V3006 Turbo Pumps, Oerlikon SL 80 800002V3001 Pumps Leybold TMP Turbo Pump Service, Sogevac Pump Repair, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Leybold Turbovac SL 80 H Turbo Pump, DN 63 CF-F, 800002V3006

 

Leybold Turbovac SL 80 H Technical Data:

  • Inlet connection: DN 63 CF
  • Outlet connection: DN 16 ISO-KF
  • Pumping speed:
    • N2 - Nitrogen: 65 l/s
    • Ar - Argon: 60 l/s
    • He - Helium: 55 l/s
    • H2 - Hydrogen: 49 l/s
  • Gas throughput:
    • N2 - Nitrogen: 0.9 mbar x l/s
    • Ar - Argon: 0.8 mbar x l/s
    • He - Helium: 1.5 mbar x l/s
    • H2 - Hydrogen: 0.6 mbar x l/s
  • Compession ratio:
    • N2 - Nitrogen: > 1.0 x 10^11
    • Ar - Argon: > 1.0 x 10^11
    • He - Helium: 6.0 x 10^6
    • H2 - Hydrogen: 8.0 x 10^4
  • Ultimate pressure: < 2.0 x 10-10 mbar | < 1.5 x 10-10 Torr
  • Max. foreline pressure for N2: 16.0 mbar | 12.0 Torr
  • Nominal rotation speed: 72000 min-1 | 72000 rpm
  • Rotational speed adaptation: 62 - 100 %
  • Run-up time: ≈ 1.5 min
  • Max. power consumption: 120 W
  • Power consumption at ultimate pressure: 17 W
  • Protection rating: IP 20
  • Admissible ambient temperature: +5 to +45 °C | +41 to +113 °F
  • Standard cooling: Convection
  • Optional cooling: Air / Water
  • Cooling water connection: G 1/8", Inside thread / 8 mm nose nozzle
  • Cooling water consumption: 15 - 60 l/h
  • Permissible cooling water pressure: 2 - 7 bar
  • Permissible cooling water temperature: +10 to +40 °C | +50 to +113 °F
  • Weight: ≈ 1.9 kg | ≈ 4.2 lbs

 

A&J Vacuum repair / rebuild and service all Leybold SL80 800002V3006 Turbo Pumps, Oerlikon SL 80 800002V3001 Pumps Leybold TMP Turbo Pump Service, Sogevac Pump Repair, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.