Fully Refurbished Leybold / Oerlikon D2.5E Rotary Vane Pump. It is coupled with a KF 16 Inlet Flange and KF 16 Outlet Flange. This Leybold / Oerlikon Rotary Vane Pump has a peak pumping velocity of 2.1 cfm and a final pressure of 1 x 10-3 Torr. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries.
A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versionsof Trivac D2.5E vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors along with all other Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
| Nominal pumping speed (50Hz | 60Hz) | 3.2 m3/h (1.9 cfm) | 3.6 m3/h (2.1 cfm) |
| Pumping speed (50Hz | 60Hz) | 2.7 m3/h (1.6 cfm) | 3.3 m3/h (1.9 cfm) |
| Ultimate partial pressure without gas ballast (50Hz | 60Hz) | ≤ 5 x 10-4 mbar (≤ 3.8 x 10-4 Torr) | ≤ 5 x 10-4 mbar (≤ 3.8 x 10-4 Torr) |
| Ultimate total pressure without gas ballast (50Hz | 60Hz) | ≤ 2 x 10-3 mbar (≤ 1.5 x 10-3 Torr) | ≤ 2 x 10-3 mbar (≤ 1.5 x 10-3 Torr) |
| Ultimate total pressure with gas ballast (50Hz | 60Hz) | ≤ 3 x 10-2 mbar (≤ 2.3 x 10-2 Torr) | ≤ 3 x 10-2 mbar (≤ 2.3 x 10-2 Torr) |
| Water vapor tolerance (50Hz | 60Hz) | Stage 1 - 10 mbar (7.5 Torr) Stage 2 - 20 mbar (15 Torr) Stage 3 - 30 mbar (22.5 Torr) |
Stage 1 - 10 mbar (7.5 Torr) Stage 2 - 20 mbar (15 Torr) Stage 3 - 30 mbar (22.5 Torr) |
| Water vapor capacity (50Hz | 60Hz) | Stage 1 - 20 g/h (0.044 lbs/h) Stage 2 - 40 g/h (0.088 lbs/h) Stage 3 - 60 mbar (0.132 lbs/h) |
Stage 1 - 25 g/h (0.055 lbs/h) Stage 2 - 50 g/h (0.110 lbs/h) Stage 3 - 75 mbar (0.165 lbs/h) |
| Oil filling, min. / max. (50Hz | 60Hz) | 0.4 / 0.7 l (0.42 / 0.74 qt) | 0.4 / 0.7 l (0.42 / 0.74 qt) |
|
Noise level (50Hz | 60Hz) |
≤ 47 dB(A) | ≤ 49 dB(A) |
| Admissible ambient temperature (50Hz | 60Hz) | +10 to +40 °C (+50 to +104 °F) | +10 to +40 °C (+50 to +104 °F) |
| Motor rating (50Hz | 60Hz) | 280 W (0.38 HP) | 300 W (0.41 HP) |
| Nominal speed (50Hz | 60Hz) | 1400 rpm | 1600 rpm |
| Type of protection (50Hz | 60Hz) | IP 54 | IP 54 |
| Connections, Intake and Exhaust (50Hz | 60Hz) | 16 KF | 16 KF |
| Weight (50Hz | 60Hz) | 16.1 kg (35.4 lbs) | 16.1 kg (35.4 lbs) |
A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versions of Trivac D2.5E vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors along with all other Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
|
Service and Repair A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
Fully Refurbished Leybold / Oerlikon D2.5E Rotary Vane Pump. It is coupled with a KF 16 Inlet Flange and KF 16 Outlet Flange. This Leybold / Oerlikon Rotary Vane Pump has a peak pumping velocity of 2.1 cfm and a final pressure of 1 x 10-3 Torr. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries.
A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versionsof Trivac D2.5E vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors along with all other Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
Specifications
| Nominal pumping speed (50Hz | 60Hz) | 3.2 m3/h (1.9 cfm) | 3.6 m3/h (2.1 cfm) |
| Pumping speed (50Hz | 60Hz) | 2.7 m3/h (1.6 cfm) | 3.3 m3/h (1.9 cfm) |
| Ultimate partial pressure without gas ballast (50Hz | 60Hz) | ≤ 5 x 10-4 mbar (≤ 3.8 x 10-4 Torr) | ≤ 5 x 10-4 mbar (≤ 3.8 x 10-4 Torr) |
| Ultimate total pressure without gas ballast (50Hz | 60Hz) | ≤ 2 x 10-3 mbar (≤ 1.5 x 10-3 Torr) | ≤ 2 x 10-3 mbar (≤ 1.5 x 10-3 Torr) |
| Ultimate total pressure with gas ballast (50Hz | 60Hz) | ≤ 3 x 10-2 mbar (≤ 2.3 x 10-2 Torr) | ≤ 3 x 10-2 mbar (≤ 2.3 x 10-2 Torr) |
| Water vapor tolerance (50Hz | 60Hz) | Stage 1 - 10 mbar (7.5 Torr) Stage 2 - 20 mbar (15 Torr) Stage 3 - 30 mbar (22.5 Torr) |
Stage 1 - 10 mbar (7.5 Torr) Stage 2 - 20 mbar (15 Torr) Stage 3 - 30 mbar (22.5 Torr) |
| Water vapor capacity (50Hz | 60Hz) | Stage 1 - 20 g/h (0.044 lbs/h) Stage 2 - 40 g/h (0.088 lbs/h) Stage 3 - 60 mbar (0.132 lbs/h) |
Stage 1 - 25 g/h (0.055 lbs/h) Stage 2 - 50 g/h (0.110 lbs/h) Stage 3 - 75 mbar (0.165 lbs/h) |
| Oil filling, min. / max. (50Hz | 60Hz) | 0.4 / 0.7 l (0.42 / 0.74 qt) | 0.4 / 0.7 l (0.42 / 0.74 qt) |
|
Noise level (50Hz | 60Hz) |
≤ 47 dB(A) | ≤ 49 dB(A) |
| Admissible ambient temperature (50Hz | 60Hz) | +10 to +40 °C (+50 to +104 °F) | +10 to +40 °C (+50 to +104 °F) |
| Motor rating (50Hz | 60Hz) | 280 W (0.38 HP) | 300 W (0.41 HP) |
| Nominal speed (50Hz | 60Hz) | 1400 rpm | 1600 rpm |
| Type of protection (50Hz | 60Hz) | IP 54 | IP 54 |
| Connections, Intake and Exhaust (50Hz | 60Hz) | 16 KF | 16 KF |
| Weight (50Hz | 60Hz) | 16.1 kg (35.4 lbs) | 16.1 kg (35.4 lbs) |
A&J Vacuum Service / rebuild and repair all Leybold vacuum pumps. We service all versions of Trivac D2.5E vacuum pumps. AJVS also provides Customers with Leybold Scroll Pump service along with Vacuum Boosters, Leybold Vacuum Pumps, Leybold Helium Leak Detectors along with all other Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
Spare Parts
Accessories
Service & Repair
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.