phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
Main Categories

Turbo Pumps & Systems

- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Category of products: V and TV Series
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Found 2 products
Item#: PN00202 Mfr Part#: 9699007 Manufacturer: Agilent Technologies / Varian
Price upon request

Fully remanufactured Varian V250 Turbo Pump, DN 100 ISO, 969-9007, TV250, also known as Varian V-250

 

Agilent / Varian V 250 Overview:


The Agilent V 250 turbo pump has the pumping speed up to 250 l/s N2. Agilent V 250 (9699007) has the compression ratio 2 x 108. The weight of Agilent V 250 is 11.4 kg. Varian V250 rotational speed is 56000 RPM. Noise level of Agilent 969-9007 is 45 dB at 1 meter.

The Varian V 250 Turbo pump p/n 9699007 consists of a high frequency motor driving a turbine fitted with 8 bladed stages and 3 Macrotorr stages. The turbine rotates in an counter clockwise direction when viewed from the high vacuum flange end. The turbine is made of high-strength, light aluminium alloy, and is machined from a single block of aluminium.

The 969-9007 Varian V-250 turbine blades have five different angles, from 42° to 10°, while the Macrotorr stages are in form of discs. The turbine rotor is supported by permanently lubricated high precision ceramic ball bearings installed on the forevacuum side of the pump. The static blades of the stator are fabricated in stainless steel with five different angles, from 36° to 10°. These are supported and accurately positioned by spacer rings.The Macrotorr stators are in the form of selfpositioning machined discs with pumping channels and an opening restricted by the corresponding rotor discs. These are made of aluminium alloy.

During normal operation, the Varian V 250 pump motor functions with a power feed at 58 Vac three-phase at 933 Hz. To reduce losses during start-up to a minimum, the frequency increases according to a ramp with a higher initial voltage/frequency ratio. The external body of the pump is fitted with fins which allow the pump itself to function with natural convection air cooling. Kits are available for water cooling or forced air cooling to cool the pump in the cases where it is used under heavy load or when natural convection is insufficient for cooling purposes. A thermistor sensor is mounted near the upper bearing to prevent the pump from overheating. The thermistor sensor, the motor stator windings and the earth are connected to a Turbo-V 250 controller p/n 9699523 / P/N 18446 through a 6 pin socket on the side of the pump.

The Varian V250 pump is balanced after assembly with a residual vibration amplitude less than 0.01. The pump can operate in any position and can be supported on the high vacuum flange or on its base. The connection of the forevacuum on the side of the pump is a KF 16 NW flange.

 

Varian V250 Compression Ratio:


Varian V250 Compression Ratio, 969-9007, 9699007

 

Varian V250 Dimensions:


Varian V250 Dimensions, 969-9007, 9699007


Click Here for Varian V250 Manual


A&J Vacuum also repair / rebuild and service Varian V250, TV250 / 9699007 Turbo Pumps along with all other Varian Turbo Pumps and Agilent Varian Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured Out of Stock
Item#: PN00203 Mfr Part#: 9699008 Manufacturer: Agilent Technologies / Varian
Price upon request

Varian V250 Turbo Pump, DN 100 CF, 969-9008, TV250, also known as Varian V-250

 

Agilent / Varian V 250 Overview:


The Agilent V 250 turbo pump has the pumping speed up to 250 l/s N2. Agilent V 250 (9699008) has the compression ratio 2 x 108. The weight of Agilent V 250 is 7.5 kg. Varian V250 rotational speed is 56000 RPM. Noise level of Agilent 969-9008 is 45 dB at 1 meter.

The Varian V250 Turbo pump p/n 9699008 consists of a high frequency motor driving a turbine fitted with 8 bladed stages and 3 Macrotorr stages. The turbine rotates in an counter clockwise direction when viewed from the high vacuum flange end. The turbine is made of high-strength, light aluminium alloy, and is machined from a single block of aluminium.

The 969-9008 Varian V250 turbine blades have five different angles, from 42° to 10°, while the Macrotorr stages are in form of discs. The turbine rotor is supported by permanently lubricated high precision ceramic ball bearings installed on the forevacuum side of the pump. The static blades of the stator are fabricated in stainless steel with five different angles, from 36° to 10°. These are supported and accurately positioned by spacer rings.The Macrotorr stators are in the form of selfpositioning machined discs with pumping channels and an opening restricted by the corresponding rotor discs. These are made of aluminium alloy.

During normal operation, the Varian V250 969-8009 pump motor functions with a power feed at 58 Vac three-phase at 933 Hz. To reduce losses during start-up to a minimum, the frequency increases according to a ramp with a higher initial voltage/frequency ratio. The external body of the pump is fitted with fins which allow the pump itself to function with natural convection air cooling. Kits are available for water cooling or forced air cooling to cool the pump in the cases where it is used under heavy load or when natural convection is insufficient for cooling purposes. A thermistor sensor is mounted near the upper bearing to prevent the pump from overheating. The thermistor sensor, the motor stator windings and the earth are connected to a Turbo V250 controller p/n 9699523 / P/N 18446 through a 6 pin socket on the side of the pump.

The pump is balanced after assembly with a residual vibration amplitude less than 0.01. The pump can operate in any position and can be supported on the high vacuum flange or on its base. The connection of the forevacuum on the side of the pump is a KF 16 NW flange.

 

Varian V250 Compression Ratio:


Varian V250 Compression Ratio, 969-9008, 9699008

 

Varian V250 Dimensions:


Varian V250 Dimensions, 969-9008, 9699008


Click Here for Varian V250 Manual


A&J Vacuum also repair / rebuild and service Varian V250, TV250 / 9699008 Turbo Pumps along with all other Varian Turbo Pumps and Agilent Varian Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured Out of Stock
Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.