Remanufactured Leybold D65BCS Vacuum Pump with CFS Oil Filtration Module, Inert Gas System and EIS Installed, PFPE Fluid, 220-240/380-420V, 50 Hz | 240-265/415-480V, 60 Hz, 3 Phase, 913992
Features:
  • P/N 913992
  • Pumping Speed: 90 m3/h
  • Fully Remanufactured
  • Loaded with All Options
12 months warranty

Leybold D65BCS Vacuum Pump with CFS Oil Filtration Module, Inert Gas System and EIS Installed, PFPE Fluid, 220-240/380-420V, 50 Hz | 240-265/415-480V, 60 Hz, 3 Phase, 913992


 

D65BCS / 913992 Overview:


Leybold TRIVAC D65 BCS pumps are PFPE oil sealed rotary vane pumps. The LEYBOLD D 40 BCS and D 65 BCS are dual-stage vacuum pumps.

The pump number in the type designation (40 or 65) indicates the pumping speed in m3.

Leybold D65BCS pumps can pump gases and vapours and evacuate vessels or vacuum systems in the fine vacuum range. This pump is equipped with PFPE lubricant return with the float controlled valve.

The drive motor of the TRIVAC B is directly flanged to the pump at the coupling housing. The pump and motor shafts are directly connected by a flexible coupling. The bearing points of the pump module are force lubricated sliding bearings. All controls as well as the oil-level glass and the nameplate are arranged on the front. All connections are to be found at the sides of the pump. The oil-level glass is provided with prisms for better observation of the oil level.

The D-65BCS pump module consists of assembly parts which are pin-fitted so as to allow easy disassembly and reassembly. The pump module can be easily removed without special tools.

 

A&J Vacuum repair / rebuild and service all Leybold D65 B, Leybold  D 65BCS TRIVAC Vacuum Pump, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Leybold D65BCS Vacuum Pump with CFS Oil Filtration Module, Inert Gas System and EIS Installed, PFPE Fluid, 220-240/380-420V, 50 Hz | 240-265/415-480V, 60 Hz, 3 Phase, 913992

 

Leybold D65BCS Technical Data:

Nominal pumping speed (50Hz | 60Hz) 75 m3/h (44 cfm) 90 m3/h (53 cfm)
Pumping speed (50Hz | 60Hz) 65 m3/h (38 cfm) 78 m3/h (46 cfm)
Ultimate partial pressure without gas ballast (50Hz | 60Hz) 10-4 mbar (0.75 x 10-4 Torr) 10-4 mbar (0.75 x 10-4 Torr)
Ultimate total pressure without gas ballast (50Hz | 60Hz) < 2 x 10-3 mbar (< 1.5 x 10-3 Torr) < 2 x 10-3 mbar (< 1.5 x 10-3 Torr)
Ultimate total pressure with gas ballast (50Hz | 60Hz) < 5 x 10-3 mbar (< 3.8 x 10-3 Torr) < 5 x 10-3 mbar (< 3.8 x 10-3 Torr)
Water vapor tolerance (50Hz | 60Hz) 40 mbar (30 Torr) 40 mbar (30 Torr)
Water vapor capacity (50Hz | 60Hz) 1925 g/h (4.244 lbs/h) 2310 g/h (5.093 lbs/h)
Oil filling, min. / max. (50Hz | 60Hz) 2.0 / 3.3 l (2.1 / 3.5 qt) 2.0 / 3.3 l (2.1 / 3.5 qt)

Noise level to DIN 45 635, without / with gas ballast (50Hz | 60Hz)

57 / 59 dB(A) 57 / 59 dB(A)
Admissible ambient temperature (50Hz | 60Hz) +12 to +40 °C (+54 to +104 °F) +12 to +40 °C (+54 to +104 °F)
Motor rating (50Hz | 60Hz) 2200 W (3.0 HP) 2200 W (3.0 HP)
Nominal speed (50Hz | 60Hz) 1460 rpm 1760 rpm
Type of protection (50Hz | 60Hz) IP 55 IP 55
Connections, Intake and Exhaust (50Hz | 60Hz) 40 KF 40 KF
Weight (50Hz | 60Hz) 84.5 kg (186.3 lbs) 84.5 kg (186.3 lbs)

 

A&J Vacuum repair / rebuild and service all Leybold D65 B, Leybold  D 65BCS TRIVAC Vacuum Pump, Leybold Boosters, Leybold  Vacuum Pumps, Leybold Helium Leak Detectors  along with all other  Leybold Turbo Pumping Stations, Leybold Turbo Pump Repair, Roots Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Item#:PN01556
Mfr Part#:19132D65KIT
Condition: In Stock New
In Stock
$504.00
Item#:PN01557
Mfr Part#:19132
Condition: In Stock New
In Stock
$285.00
Item#:PN12133
Mfr Part#:E35001179 / 35001179
Condition: In Stock New
In Stock
$49.99
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.