phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823
Item#: PN23977 Mfr Part#: 102823/102823 Manufacturer: Pfeiffer Vacuum
Condition: New
New Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823

Features:
  • OEM P/N 102823

PRICE: $500.00
WEB SAVINGS: $75.00
YOU PAY: $425.00
Item#: PN23977 Mfr Part#: 102823/102823
Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823
Item#: PN23977 Mfr Part#: 102823/102823 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for  Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823

Special Elastomer Seal Overview:


Alcatel Adixen Helium Leak Detector Elastomer seal is compatible with the following leak detectors:

  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182
This item is non-returnable/non-refundable

Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for  Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823

Special Elastomer Seal Overview:


Alcatel Adixen Helium Leak Detector Elastomer seal is compatible with the following leak detectors:

  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823
Item#: PN23977 Mfr Part#: 102823/102823 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for  Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823

Special Elastomer Seal Overview:


Alcatel Adixen Helium Leak Detector Elastomer seal is compatible with the following leak detectors:

  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182

Pfeiffer Adixen Analyzer Cell Elastomer Seal Gasket for  Helium Leak Detectors models ASM 142, ASM 150, ASM 151, 181 TD+, ASM 182 Leak Detectors, 102823

Special Elastomer Seal Overview:


Alcatel Adixen Helium Leak Detector Elastomer seal is compatible with the following leak detectors:

  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.