Shopping Cart ( )

Edwards nEXT400IID UHV-160W Turbo Molecular Pump for Thermo Fisher Scientific, B832-00-816 / B83200816

Condition: Remanufactured
In Stock
Item#:PN40638
Mfr Part#:B832-00-816 / B83200816
Manufacturer:Leybold
PRICE:
$14,025.00
Web savings:
$8,075.00
YOU PAY:
$5,950.00
Remanufactured Edwards nEXT400IID UHV-160W Turbo Molecular Pump for Thermo Fisher Scientific, B832-00-816 / B83200816
Features:
  • Edwards P/N B832-00-816
  • Thermo Fisher
  • Fullly Remanufactured !
  • Edwards Vacuum
6 months warranty

Edwards nEXT400IID UHV-160W Turbo Molecular Pump for Thermo Fisher Scientific, B832-00-816 / B83200816


 

nEXT400IID UHV-160W / B83200816 Overview:


The Edwards nEXT400IID UHV Turbo Pump is a specialt Turbo Pump designed for Thermo Fisher Mass Spectrometers Instruments to evacuate up to three vacuum chambers. The nEXT400IID / B832-00-816 have a mounting housing and is designed to be integrated into a Thermo Fisher Scientific.

Edwards nEXT400IID Turbomolecular Pumps are suitable for pumping air and clean gases.

The Edwards nEXT400 IID pump is built in custom multi inlet housing.

A&J Vacuum also repair / rebuild and service Edwards nEXT 400II D Turbo Pump repair along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Edwards nEXT400IID UHV-160W Turbo Molecular Pump for Thermo Fisher Scientific, B832-00-816 / B83200816


 

nEXT400IID UHV-160W / B83200816 Overview:


The Edwards nEXT400IID UHV Turbo Pump is a specialt Turbo Pump designed for Thermo Fisher Mass Spectrometers Instruments to evacuate up to three vacuum chambers. The nEXT400IID / B832-00-816 have a mounting housing and is designed to be integrated into a Thermo Fisher Scientific.

Edwards nEXT400IID Turbomolecular Pumps are suitable for pumping air and clean gases.

The Edwards nEXT400 IID pump is built in custom multi inlet housing.

A&J Vacuum also repair / rebuild and service Edwards nEXT 400II D Turbo Pump repair along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.