Overview
Titrette® Bottletop Burette
The BRAND Titrette® is the only bottletop burette that meets Class A accuracy specifications for glass burettes. If needed, it can offer the precision of 3 decimal places below 20mL. It can be quickly and easily disassembled in a matter of minutes - for cleaning, to replace the piston or cylinder, or to replace the batteries. Available in volumes from 10mL to 50mL, and with an optional RS232 communications interface.
Titrette® offers the following features:
The 45mm standard thread, plus included adapters, fit most common lab bottles
Titrating tube can be adjusted horizontally and vertically
Integrated SafetyPrime™valve reduces waste of valuable reagents
Clip-on amber-colored window protects light-sensitive reagents
Valves replaceable for simple, economical service
Large handwheels provide smooth, precise control
Compact design and light weight ensure good stability
BrandTech Titrette® Bottletop Burette Operating Instructions Click Here
BrandTech Titrette® Bottletop Burette, 25 mL, with Optional RS232 Communications Interface, 4760251
The Titrette® bottletop burette is supplied with: 45mm thread, telescoping filling tube (170-330mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 bottletop adapters, 2 amber colored light shield inspection windows, performance certificate, operating manual, and one-year warranty. Additionally included with RS232 interface: 2m interface cable (9-pin, sub-D plug connector), CD (driver software and open RS232 communication protocol).
Volume
mL |
Partial Volume
mL |
A* ≤ ±
|
CV* ≤
|
Standard
Cat. No. |
Interface
Cat. No. |
||
---|---|---|---|---|---|---|---|
%
|
µL
|
%
|
µL
|
||||
10
|
10
|
0.10
|
10
|
0.05
|
5
|
4760141
|
4760241
|
|
5
|
0.20
|
10
|
0.10
|
5
|
|
|
|
1
|
1.00
|
10
|
0.50
|
5
|
|
|
25
|
25
|
0.07
|
18
|
0.025
|
6
|
4760151
|
4760251
|
|
12.5
|
0.14
|
18
|
0.05
|
6
|
|
|
|
2.5
|
0.70
|
18
|
0.25
|
6
|
|
|
50
|
50
|
0.06
|
30
|
0.02
|
10
|
4760161
|
4760261
|
|
25
|
0.12
|
30
|
0.04
|
10
|
|
|
|
5
|
0.60
|
30
|
0.20
|
10
|
|
|
A*=Accuracy, CV*=Coefficient of Variation
*The value of accuracy and coefficient of variation are final test values referring ot the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.
Overview
Titrette® Bottletop Burette
Titrette® Bottletop Burette is supplied with following items:
45mm thread
Performace certificate
Telescoping filling tube, 170-330mm
Recirculation tube
2 batteries, AAA/UM4/LR03
4 PP bottle adapters, 45/33mm, 45/S40mm, 33mm/STJ29/32 and 45/38mm
2 colored light shield inspection windows
Operating manual
One-year warranty
Limitations of Use:
This instrument is designed for dispensing liquids, observing the following physical limits:
Temperature of instrument and reagent must be between +15°C and +40°C (59°F and 104°F)
Altitude: maximum 3000m above sea-level
Relative air humididty: 20% to 90%
Vapor pressure up to 500 mbar
Viscosity up to 500 mm²/s
Operating Exclusions:
Never use this instrument with:
Liquids attacking Al2O3, ETFE, FEP, PFA, PTFE or platinum-iridium
Liquids attacking borosilicate glass (e.g., hydrofluoric acid)
Suspensions (e.g., of charcoal) as solid particles may clog or damage the instrument
Liquids which are explosive or flammable (e.g., carbon disulfide)
Concentrated acids and bases as well as non-polar solvents which effect swelling of plastics (e.g., Toluene, Benzene)
The instrument should not be autoclaved!
The instrument should not be used in an aggressive atmosphere (e.g., HCl fumes).
BrandTech Titrette® Bottletop Burette Operating Instructions Click Here
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
Titrette® Bottletop Burette
The BRAND Titrette® is the only bottletop burette that meets Class A accuracy specifications for glass burettes. If needed, it can offer the precision of 3 decimal places below 20mL. It can be quickly and easily disassembled in a matter of minutes - for cleaning, to replace the piston or cylinder, or to replace the batteries. Available in volumes from 10mL to 50mL, and with an optional RS232 communications interface.
Titrette® offers the following features:
The 45mm standard thread, plus included adapters, fit most common lab bottles
Titrating tube can be adjusted horizontally and vertically
Integrated SafetyPrime™valve reduces waste of valuable reagents
Clip-on amber-colored window protects light-sensitive reagents
Valves replaceable for simple, economical service
Large handwheels provide smooth, precise control
Compact design and light weight ensure good stability
BrandTech Titrette® Bottletop Burette Operating Instructions Click Here
BrandTech Titrette® Bottletop Burette, 25 mL, with Optional RS232 Communications Interface, 4760251
The Titrette® bottletop burette is supplied with: 45mm thread, telescoping filling tube (170-330mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 bottletop adapters, 2 amber colored light shield inspection windows, performance certificate, operating manual, and one-year warranty. Additionally included with RS232 interface: 2m interface cable (9-pin, sub-D plug connector), CD (driver software and open RS232 communication protocol).
Volume
mL |
Partial Volume
mL |
A* ≤ ±
|
CV* ≤
|
Standard
Cat. No. |
Interface
Cat. No. |
||
---|---|---|---|---|---|---|---|
%
|
µL
|
%
|
µL
|
||||
10
|
10
|
0.10
|
10
|
0.05
|
5
|
4760141
|
4760241
|
|
5
|
0.20
|
10
|
0.10
|
5
|
|
|
|
1
|
1.00
|
10
|
0.50
|
5
|
|
|
25
|
25
|
0.07
|
18
|
0.025
|
6
|
4760151
|
4760251
|
|
12.5
|
0.14
|
18
|
0.05
|
6
|
|
|
|
2.5
|
0.70
|
18
|
0.25
|
6
|
|
|
50
|
50
|
0.06
|
30
|
0.02
|
10
|
4760161
|
4760261
|
|
25
|
0.12
|
30
|
0.04
|
10
|
|
|
|
5
|
0.60
|
30
|
0.20
|
10
|
|
|
A*=Accuracy, CV*=Coefficient of Variation
*The value of accuracy and coefficient of variation are final test values referring ot the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.
Overview
Titrette® Bottletop Burette
Titrette® Bottletop Burette is supplied with following items:
45mm thread
Performace certificate
Telescoping filling tube, 170-330mm
Recirculation tube
2 batteries, AAA/UM4/LR03
4 PP bottle adapters, 45/33mm, 45/S40mm, 33mm/STJ29/32 and 45/38mm
2 colored light shield inspection windows
Operating manual
One-year warranty
Limitations of Use:
This instrument is designed for dispensing liquids, observing the following physical limits:
Temperature of instrument and reagent must be between +15°C and +40°C (59°F and 104°F)
Altitude: maximum 3000m above sea-level
Relative air humididty: 20% to 90%
Vapor pressure up to 500 mbar
Viscosity up to 500 mm²/s
Operating Exclusions:
Never use this instrument with:
Liquids attacking Al2O3, ETFE, FEP, PFA, PTFE or platinum-iridium
Liquids attacking borosilicate glass (e.g., hydrofluoric acid)
Suspensions (e.g., of charcoal) as solid particles may clog or damage the instrument
Liquids which are explosive or flammable (e.g., carbon disulfide)
Concentrated acids and bases as well as non-polar solvents which effect swelling of plastics (e.g., Toluene, Benzene)
The instrument should not be autoclaved!
The instrument should not be used in an aggressive atmosphere (e.g., HCl fumes).
BrandTech Titrette® Bottletop Burette Operating Instructions Click Here
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.