Transferpettor Positive Displacement Pipette
The Transferpettor positive displacement pipette is the ideal tool for use with liquids that render traditional air displacement pipettes ineffective. Unlike air displacement pipettes, the piston of the Transferpettor directly expels the media from the tip, wiping the tip walls completely clean. This results in negligible residual wetting and highly accurate, reproducible results, especially with viscous, foaming, high-vapor-pressure, and other "problematic" liquids.
Product Features:
The Transferpettor is an excellent toll for applications in wastewater treatment plants, biochemicalm genetics and molecular biology laboratories, wineries, breweries, refineries, and more.
For use with viscous solutions up to 40,000cSt (mm²/s) and high density media (up to 13.6g/cm³) such as concentrated protein solutions, oild, fats, resins, and glycerin.
Use the Transferpettor to accurately pipette surfactants such as Tween 20, Mucasol, and more.
The Transferpettor is designed for use with high-vapor-pressure media (up to 500mbar), including alcohols, acetone, and hydrocarbons that would otherwise vaporize into an air displacement tip.
Because residual wetting is negligible, the Transferpettor reduces lab costs by eliminating the need to discard tips after each use.
BrandTech Transferpettor Positive Displacement Pipette Operating Instructions, Click Here
The Transferpettor™ is supplied with one tip & seal, seal mounting/removal tool, performance certificate, operating manual, and one year warranty.
Capacity
|
A* < ±
|
CV* ≤
|
Max. Viscosity
mm2/sec |
Subdivision
µL |
Color
|
Cat. No.
|
||
---|---|---|---|---|---|---|---|---|
%
|
µL
|
%
|
µL
|
|||||
100-500µL
|
0.5
|
2.5
|
0.2
|
1.0
|
40,000
|
1.0
|
Green
|
702804
|
200-1000µL
|
0.5
|
5.0
|
0.2
|
2.0
|
20,000
|
1.0
|
Yellow
|
702806
|
1-5mL
|
0.5
|
25.0
|
0.2
|
10.0
|
6,000
|
10
|
Red
|
702810
|
2-10mL
|
0.5
|
50.0
|
0.2
|
20.0
|
2,000
|
10
|
Orange
|
702812
|
A*=Accuracy, CV*=Coefficient of Variation
*The value of accuracy and coefficient of variation are final test values referring to the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.
Limitations of Use:
This instrument is intended for the pipetting of liquids within the following limitations:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Density up to 13.6 g/cm³
Kinematic viscosity:
500µl instrument: 40,000 mm²/s
1000µl instrument: 20,000 mm²/s
5,000µl instrument: 6,000 mm²/s
10,000µl instrument: 2,000 mm²/s
Operating Exclusions:
This instrument cannot be used with:
Liquids incompatible with polypropylene or polyethylene
Crystallizing liquids as they may damage the seal
BrandTech Transferpettor Positive Displacement Pipette Operating Instructions, Click Here
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
Transferpettor Positive Displacement Pipette
The Transferpettor positive displacement pipette is the ideal tool for use with liquids that render traditional air displacement pipettes ineffective. Unlike air displacement pipettes, the piston of the Transferpettor directly expels the media from the tip, wiping the tip walls completely clean. This results in negligible residual wetting and highly accurate, reproducible results, especially with viscous, foaming, high-vapor-pressure, and other "problematic" liquids.
Product Features:
The Transferpettor is an excellent toll for applications in wastewater treatment plants, biochemicalm genetics and molecular biology laboratories, wineries, breweries, refineries, and more.
For use with viscous solutions up to 40,000cSt (mm²/s) and high density media (up to 13.6g/cm³) such as concentrated protein solutions, oild, fats, resins, and glycerin.
Use the Transferpettor to accurately pipette surfactants such as Tween 20, Mucasol, and more.
The Transferpettor is designed for use with high-vapor-pressure media (up to 500mbar), including alcohols, acetone, and hydrocarbons that would otherwise vaporize into an air displacement tip.
Because residual wetting is negligible, the Transferpettor reduces lab costs by eliminating the need to discard tips after each use.
BrandTech Transferpettor Positive Displacement Pipette Operating Instructions, Click Here
The Transferpettor™ is supplied with one tip & seal, seal mounting/removal tool, performance certificate, operating manual, and one year warranty.
Capacity
|
A* < ±
|
CV* ≤
|
Max. Viscosity
mm2/sec |
Subdivision
µL |
Color
|
Cat. No.
|
||
---|---|---|---|---|---|---|---|---|
%
|
µL
|
%
|
µL
|
|||||
100-500µL
|
0.5
|
2.5
|
0.2
|
1.0
|
40,000
|
1.0
|
Green
|
702804
|
200-1000µL
|
0.5
|
5.0
|
0.2
|
2.0
|
20,000
|
1.0
|
Yellow
|
702806
|
1-5mL
|
0.5
|
25.0
|
0.2
|
10.0
|
6,000
|
10
|
Red
|
702810
|
2-10mL
|
0.5
|
50.0
|
0.2
|
20.0
|
2,000
|
10
|
Orange
|
702812
|
A*=Accuracy, CV*=Coefficient of Variation
*The value of accuracy and coefficient of variation are final test values referring to the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.
Limitations of Use:
This instrument is intended for the pipetting of liquids within the following limitations:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Density up to 13.6 g/cm³
Kinematic viscosity:
500µl instrument: 40,000 mm²/s
1000µl instrument: 20,000 mm²/s
5,000µl instrument: 6,000 mm²/s
10,000µl instrument: 2,000 mm²/s
Operating Exclusions:
This instrument cannot be used with:
Liquids incompatible with polypropylene or polyethylene
Crystallizing liquids as they may damage the seal
BrandTech Transferpettor Positive Displacement Pipette Operating Instructions, Click Here
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.