Edwards Inverted Magnetron Gauge AIM XL NW25 (AIMXLNW25), AIM-XL-NW25, D14645000
The Edwards AIM Active Inverted Magnetron Gauges (AIM) combine the gauge-head and controller in one compact Active AIM XL unit. Low magnetic field version XL for sensitive applications.These gauges have proved to be rugged and reliable in a wide range of applications ranging from scientific instruments to industrial processes.
This gauge has a low external magnetic field making it suitable for use with sensitive analytical instruments or maglev turbo pumps. In addition, this gauge features a linear output for easy integration with a computer or PLC.
Technology
The Edwards AIM-XL-NW25 Gauge is an inverted magnetron gauge head and gauge controller in a single compact unit. The gauge operates as a cold cathode ionisation gauge, in which pressure is measured indirectly as a function of the current that flows in a Townsend discharge maintained in the body tube.
The measurement range of the AIM-XL-NW25 Gauge is 1 x 10-9 to 1 x 10-2 mbar.
The AIM Gauge requires a 13.5 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure.
The AIM-XL-NW25 Gauge is compatible with all of Edwards Active Gauge Controllers and with the appropriate versions of the Active Gauge Displays. Alternatively you can use an independent power supply for the AIM Gauge and you can read the AIM Gauge output signal with a voltmeter or an analogue-to-digital converter.
Applications
All vacuum applications requiring rugged and reliable pressure indication in the range 1 x 10-2 to 1 x 10-9 mbar. Typical processes range from general vacuum through industrial coaters and furnaces to scientific instruments and semicon.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.
Pressure Range | |
AIM-X and AIM-XL | 10-2 to 10-9 mbar |
Accuracy* | Typically ±30% |
Maximum overpressure | 10 bar absolute (145 psi) |
Power supply | +13.5 to +36V d.c. (max 1 V ripple) |
Power consumption | 2 W Maximum |
Output signal | 2 to 10 V d.c. |
Set point | Open collector transistor |
Maximum voltage | 40V d.c. |
Current | 100 mA max |
Temperature range | |
Operating | +5 to +60°C |
Storage | 0 to +70°C |
Baking (DN40CF version only) | 300 o C with electronics removed DN40CF only |
Materials exposed to vacuum | |
NW25 versions | Stainless steel 304 & 306 & 347, fluoroelastomer, glass |
DN40CF | Stainless steel (AISI 304 and 306), copper, ceramic, very small amount of copper braze |
Internal volume | 26 cm3 |
Weight | 0.81 kg |
AIM-X NW25 | 810 g |
AIM-XL NW25 | 860 g |
AIM-X DN40CF | 1090 g |
AIM-XL DN40CF | 1140 g |
External interface connector | 8-way FCC68/RJ45 socket |
Vacuum fitting | NW25 |
Standards | |
Electromagnetic compatibility | EN 61326 (Class B Emissions) |
Enclosure rating | IP40 |
A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Edwards Inverted Magnetron Gauge AIM XL NW25 (AIMXLNW25), AIM-XL-NW25, D14645000
The Edwards AIM Active Inverted Magnetron Gauges (AIM) combine the gauge-head and controller in one compact Active AIM XL unit. Low magnetic field version XL for sensitive applications.These gauges have proved to be rugged and reliable in a wide range of applications ranging from scientific instruments to industrial processes.
This gauge has a low external magnetic field making it suitable for use with sensitive analytical instruments or maglev turbo pumps. In addition, this gauge features a linear output for easy integration with a computer or PLC.
Technology
The Edwards AIM-XL-NW25 Gauge is an inverted magnetron gauge head and gauge controller in a single compact unit. The gauge operates as a cold cathode ionisation gauge, in which pressure is measured indirectly as a function of the current that flows in a Townsend discharge maintained in the body tube.
The measurement range of the AIM-XL-NW25 Gauge is 1 x 10-9 to 1 x 10-2 mbar.
The AIM Gauge requires a 13.5 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure.
The AIM-XL-NW25 Gauge is compatible with all of Edwards Active Gauge Controllers and with the appropriate versions of the Active Gauge Displays. Alternatively you can use an independent power supply for the AIM Gauge and you can read the AIM Gauge output signal with a voltmeter or an analogue-to-digital converter.
Applications
All vacuum applications requiring rugged and reliable pressure indication in the range 1 x 10-2 to 1 x 10-9 mbar. Typical processes range from general vacuum through industrial coaters and furnaces to scientific instruments and semicon.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.
Pressure Range | |
AIM-X and AIM-XL | 10-2 to 10-9 mbar |
Accuracy* | Typically ±30% |
Maximum overpressure | 10 bar absolute (145 psi) |
Power supply | +13.5 to +36V d.c. (max 1 V ripple) |
Power consumption | 2 W Maximum |
Output signal | 2 to 10 V d.c. |
Set point | Open collector transistor |
Maximum voltage | 40V d.c. |
Current | 100 mA max |
Temperature range | |
Operating | +5 to +60°C |
Storage | 0 to +70°C |
Baking (DN40CF version only) | 300 o C with electronics removed DN40CF only |
Materials exposed to vacuum | |
NW25 versions | Stainless steel 304 & 306 & 347, fluoroelastomer, glass |
DN40CF | Stainless steel (AISI 304 and 306), copper, ceramic, very small amount of copper braze |
Internal volume | 26 cm3 |
Weight | 0.81 kg |
AIM-X NW25 | 810 g |
AIM-XL NW25 | 860 g |
AIM-X DN40CF | 1090 g |
AIM-XL DN40CF | 1140 g |
External interface connector | 8-way FCC68/RJ45 socket |
Vacuum fitting | NW25 |
Standards | |
Electromagnetic compatibility | EN 61326 (Class B Emissions) |
Enclosure rating | IP40 |
A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.