phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer Vacuum PCR 260, Compact Pirani Capacitance Gauge, DN 16 ISO KF, PTR26850 THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE PCR 280. PLEASE REFER TO ITEM# PN07366.
Item#: PN07384 Mfr Part#: PTR26850 Manufacturer: Pfeiffer Vacuum
Condition: Discontinued
Discontinued THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE UPDATED PCR 280 MODEL GAUGE. PLEASE REFER TO ITEM # 07366.

Features:

This product has been discontinued and is no longer available for sale
Item#: PN07384 Mfr Part#: PTR26850
Pfeiffer Vacuum PCR 260, Compact Pirani Capacitance Gauge, DN 16 ISO KF, PTR26850 THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE PCR 280. PLEASE REFER TO ITEM# PN07366.
Item#: PN07384 Mfr Part#: PTR26850 Manufacturer: Pfeiffer Vacuum

THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE UPDATED PCR 280 MODEL GAUGE. PLEASE REFER TO ITEM # 07366.

 

Product Overview - Pfeiffer Vacuum PCR 260 Dual Pirani/Capacitance Gauge:


The Pfeiffer Vacuum PCR 260 Compact Dual Pirani Capacitance Gauge has been designed for vacuum measurement of gases within pressure range of 5 * 10^[-5] to 1500 mbar. It must not be used for measuring flammable or combustible gases in mixtures containing oxidants (e.g. atmospheric oxygen) within the explosion range.

The Pfeiffer PCR 260 is a dual-combination transmitter consisting of both a Pirani sensor and a diaphragm Capacitance sensor, all within a single measurement chamber. Both sensors are programmed to remain active during the measurement process.

At low pressures, only the signal of the Pirani sensor is utilized for pressure measurement; while at higher pressures, solely that of the diaphragm Capacitance sensor is utilized. To determine the output signal in the intermediate pressure range, both signals are used proportionally to respond to the pressure and establish a reading.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF OPENED OR USED*


A&J Vacuum services and repairs Pfeiffer Vacuum PCR 260 Series Dual Pirani/Capacitance Transmitters, along with all other Pfeiffer Vacuum transmitters, pressure gauges, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.

This item is non-returnable/non-refundable
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum PCR 260, Compact Pirani Capacitance Gauge, DN 16 ISO KF, PTR26850 THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE PCR 280. PLEASE REFER TO ITEM# PN07366.
Item#: PN07384 Mfr Part#: PTR26850 Manufacturer: Pfeiffer Vacuum

THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE UPDATED PCR 280 MODEL GAUGE. PLEASE REFER TO ITEM # 07366.

 

Product Overview - Pfeiffer Vacuum PCR 260 Dual Pirani/Capacitance Gauge:


The Pfeiffer Vacuum PCR 260 Compact Dual Pirani Capacitance Gauge has been designed for vacuum measurement of gases within pressure range of 5 * 10^[-5] to 1500 mbar. It must not be used for measuring flammable or combustible gases in mixtures containing oxidants (e.g. atmospheric oxygen) within the explosion range.

The Pfeiffer PCR 260 is a dual-combination transmitter consisting of both a Pirani sensor and a diaphragm Capacitance sensor, all within a single measurement chamber. Both sensors are programmed to remain active during the measurement process.

At low pressures, only the signal of the Pirani sensor is utilized for pressure measurement; while at higher pressures, solely that of the diaphragm Capacitance sensor is utilized. To determine the output signal in the intermediate pressure range, both signals are used proportionally to respond to the pressure and establish a reading.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF OPENED OR USED*


A&J Vacuum services and repairs Pfeiffer Vacuum PCR 260 Series Dual Pirani/Capacitance Transmitters, along with all other Pfeiffer Vacuum transmitters, pressure gauges, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.