The Pfeiffer HiPace 300 Plus PMP03982 100 ISO-F is a complete line of compact yet powerful Pfeiffer turbo pumps featuring pumping speed of 245 l/s N2. These Hipace 300 plus models are cost-effective and offer flexible installation in any orientation. The proven bearing system provides unrivaled dependability and their sophisticated rotor design makes for higher pumping speeds, higher backing pump compatibility, higher gas throughputs and good compression for light gasses.
The Pfeiffer Hipace 300 Plus Turbo Pump proven bearing system provides unrivaled dependability and their sophisticated rotor design makes for higher pumping speeds, higher backing pump compatibility, higher gas throughputs and good compression for light gasses.
This HiPace 300 Plus Turbo Pump comes with a TC-110 Controller.
Complete Operating Instruction for HiPace 300 Plus PM P03 982 is available in PDF format below.
Click Here to view Pfeiffer Vacuum HiPace 300 Plus Turbo Pump Operating Instructions
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum Hipace 300 plus Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
Bearing | Hybrid |
Compression ratio for Ar | > 1 · 1011 |
Compression ratio for H2 | 9 · 105 |
Compression ratio for He | > 1 · 108 |
Compression ratio for N2 | > 1 · 1011 |
Cooling method, optional | Water |
Cooling method, standard | Air |
Cooling water flow | 50 l/h |
Cooling water flow, max | 50 l/h |
Cooling water flow, min | 50 l/h |
Cooling water temperature | 15-35 °C | 59-95 °F | 288-308 K |
Current max. | 7,5 A |
Electronic drive unit | with TC 110 |
Flange (in) | DN 100 ISO-F |
Flange (out) | DN 16 ISO-KF/G ¼" |
Fore-vacuum max. for N2 | 15 hPa | 11.25 Torr | 15 mbar |
Gas throughput at full rotational speed for Ar | 2 hPa·l/s |
Gas throughput at full rotational speed for H2 | > 14 hPa·l/s |
Gas throughput at full rotational speed for He | 8 hPa·l/s |
Gas throughput at full rotational speed for N2 | 5 hPa·l/s |
I/O interfaces | RS-485, Remote |
Interface, extended | Profibus, DeviceNet, E74 |
Low vibrations | YES |
Mounting orientation | 0° (HV flange top) |
Operating voltage: V DC | 24 (± 5 %) V DC |
Permissible magnetic field max. | 5.5 mT |
Power consumption max. | 180 W |
Protection category | IP54 |
Pumping speed for Ar | 255 l/s |
Pumping speed for H2 | 220 l/s |
Pumping speed for He | 255 l/s |
Pumping speed for N2 | 260 l/s |
Rotation speed ± 2 % | 60,000 rpm | 60,000 min-1 |
Rotation speed variable | 35 – 100 % |
Run-up time | 3.5 min |
Sound pressure level | ≤50 dB(A) |
Ultimate pressure according to PNEUROP | < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar |
Ultimate pressure without gas ballast | 1 · 10-7 hPa | 7.5 · 10-8 Torr | 1 · 10-7 mbar |
Venting connection | G 1/8" |
Weight | 6.1 kg | 13.45 lb |
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum Hipace 300 Plus PMP03898 Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The Pfeiffer HiPace 300 Plus PMP03982 100 ISO-F is a complete line of compact yet powerful Pfeiffer turbo pumps featuring pumping speed of 245 l/s N2. These Hipace 300 plus models are cost-effective and offer flexible installation in any orientation. The proven bearing system provides unrivaled dependability and their sophisticated rotor design makes for higher pumping speeds, higher backing pump compatibility, higher gas throughputs and good compression for light gasses.
The Pfeiffer Hipace 300 Plus Turbo Pump proven bearing system provides unrivaled dependability and their sophisticated rotor design makes for higher pumping speeds, higher backing pump compatibility, higher gas throughputs and good compression for light gasses.
This HiPace 300 Plus Turbo Pump comes with a TC-110 Controller.
Complete Operating Instruction for HiPace 300 Plus PM P03 982 is available in PDF format below.
Click Here to view Pfeiffer Vacuum HiPace 300 Plus Turbo Pump Operating Instructions
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum Hipace 300 plus Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
Bearing | Hybrid |
Compression ratio for Ar | > 1 · 1011 |
Compression ratio for H2 | 9 · 105 |
Compression ratio for He | > 1 · 108 |
Compression ratio for N2 | > 1 · 1011 |
Cooling method, optional | Water |
Cooling method, standard | Air |
Cooling water flow | 50 l/h |
Cooling water flow, max | 50 l/h |
Cooling water flow, min | 50 l/h |
Cooling water temperature | 15-35 °C | 59-95 °F | 288-308 K |
Current max. | 7,5 A |
Electronic drive unit | with TC 110 |
Flange (in) | DN 100 ISO-F |
Flange (out) | DN 16 ISO-KF/G ¼" |
Fore-vacuum max. for N2 | 15 hPa | 11.25 Torr | 15 mbar |
Gas throughput at full rotational speed for Ar | 2 hPa·l/s |
Gas throughput at full rotational speed for H2 | > 14 hPa·l/s |
Gas throughput at full rotational speed for He | 8 hPa·l/s |
Gas throughput at full rotational speed for N2 | 5 hPa·l/s |
I/O interfaces | RS-485, Remote |
Interface, extended | Profibus, DeviceNet, E74 |
Low vibrations | YES |
Mounting orientation | 0° (HV flange top) |
Operating voltage: V DC | 24 (± 5 %) V DC |
Permissible magnetic field max. | 5.5 mT |
Power consumption max. | 180 W |
Protection category | IP54 |
Pumping speed for Ar | 255 l/s |
Pumping speed for H2 | 220 l/s |
Pumping speed for He | 255 l/s |
Pumping speed for N2 | 260 l/s |
Rotation speed ± 2 % | 60,000 rpm | 60,000 min-1 |
Rotation speed variable | 35 – 100 % |
Run-up time | 3.5 min |
Sound pressure level | ≤50 dB(A) |
Ultimate pressure according to PNEUROP | < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar |
Ultimate pressure without gas ballast | 1 · 10-7 hPa | 7.5 · 10-8 Torr | 1 · 10-7 mbar |
Venting connection | G 1/8" |
Weight | 6.1 kg | 13.45 lb |
A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum Hipace 300 Plus PMP03898 Turbo Pumps along with all other Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.