phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
Main Categories

- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Category of products: Edwards Vacuum
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Found 20 products
Item#: PN06454 Mfr Part#: A34315903 Manufacturer: Edwards Vacuum
PRICE: $3,380.00
WEB SAVINGS: $555.00
YOU PAY: $2,825.00

Fuly Rebuilt Edwards E1M18 Single Stage Rotary Vane Vacuum Pump, 230 V, Single Phase, A34315903

 

Edwards E1M18 Overview:


The Edwards E1M18 / A34315903 vacuum pumps are direct drive, sliding vane pumps. The E1M18 is a single-stage pump, and the Edwards E2M18 is a two-stage pump.

The Edwards E1M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards E1M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E1M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured In Stock
Item#: PN22132 Mfr Part#: A34324904 Manufacturer: Edwards Vacuum
PRICE: $2,895.00
WEB SAVINGS: $596.00
YOU PAY: $2,299.00

Fuly Rebuilt Edwards E1M18 Vacuum Pump, Single Stage Rotary Vane 100 V / 200 V 50 Hz, 100-105 / 200-210 60Hz Single Phase, A34324904, A343-24-904

 

Edwards E1M18 Overview:


The Edwards E1M18 / A34324904 vacuum pumps are direct drive, sliding vane pumps. The E1M18 is a single-stage pump, and the Edwards E2M18 is a two-stage pump.

The Edwards E1M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards E1M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E1M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured In Stock
Item#: PN23873 Mfr Part#: A34317984 Manufacturer: Edwards Vacuum
PRICE: $0.00
YOU PAY: $2,995.00

Fuly Rebuilt Edwards E2M18 Vacuum Pump, Dual Stage Rotary Vane Pump, Dual Voltage, A34317984

 

Edwards E2M18 Overview:


Edwards E2M18 A34317984 is a single stage oil sealed rotary vane pump which has a pressurized oil system that lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents oil suckback unless the gas ballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow either gravity oil drain or pressure oil drain.

 

Edwards E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


200-240 VAC / 50Hz

200-230 VAC / 60Hz

110 VAC / 50 Hz

115-120 VAC / 60Hz

Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: In Stock
Item#: PN36197 Mfr Part#: A373-24-930 / A37324930 / G1969-80230 Manufacturer: Edwards Vacuum
PRICE: $9,170.00
WEB SAVINGS: $2,320.00
YOU PAY: $6,850.00

Edwards E2M28 Vacuum Pump, Hydrocarbon Oil, Dual Stage, 230 VAC, (220 to 264 VAC) 50/60 Hz, A373-24-930 / A37324930 / Agilent G1969-80230

 

Edwards / Agilent E2M28 / G1969-80230 Pump Overview:


The Edwards Agilent E2M28 A373-24-930 Rotary Vane Vacuum Pump is a two-stage, direct drive, sliding vane vacuum pump.

The Agilent P/N G1969-80230 pump is used with Agilent TOF 62XX series, Agilent triple Agilent Quad 64XX series, and Agilent Q-TOF 65XX series, models 62XX, G6410A/B, G6430A, G6460A, G6510A, G6520B, G6530A, G6538A, and G6540A

The pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The Edwards E2M28 electric motor are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

The single-phase motors have a thermal overload device. When the E2M28 motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

Edwards E2M28 oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gas-ballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminum alloy baseplate on rubber pads.

 

Edwards E2M28 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M28 Dimensions:


Edwards E2M28, A37315903, Dimensions


Click Here for Edwards E2M28 and E2M30 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured In Stock
Item#: PN40974 Mfr Part#: A36315903 Manufacturer: Edwards Vacuum
PRICE: $4,900.00
WEB SAVINGS: $1,450.00
YOU PAY: $3,450.00

Fuly Rebuilt Edwards E2M18 Vacuum Pump 220-240 VAC 50 Hz, 220-230 VAC 60 Hz, Single Phase, A36315903

 

Edwards E2M18 / A36315903


The Edwards E2M18 / A36315903 vacuum pumps are direct drive, sliding vane pumps. The E2M18 is a dual-stage vaccuum pump.

The Edwards E2M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Agilent Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: In Stock
Item#: PN40975 Mfr Part#: A36324930 / A363-24-930 Manufacturer: Edwards Vacuum
PRICE: $4,900.00
WEB SAVINGS: $1,450.00
YOU PAY: $3,450.00

Fuly Rebuilt Edwards E2M18 Vacuum Pump 220-240 VAC 50 Hz, 220-230 VAC 60 Hz, Single Phase, A36324930 / A363-24-930

 

Edwards E2M18 / A36324930


The Edwards E2M18 / A36324930 vacuum pumps are direct drive, sliding vane pumps. The E2M18 is a dual-stage vaccuum pump.

The Edwards E2M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Agilent Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured In Stock
Item#: PN40993 Mfr Part#: NRA5-01-000 / NRA501000 Manufacturer: Edwards Vacuum
PRICE: $4,900.00
WEB SAVINGS: $1,450.00
YOU PAY: $3,450.00

Fuly Rebuilt Edwards E2M18 Vacuum Pump 208 VAC 60 Hz, Single Phase, 100-105 / 200-210 VAC, Agilent NRA5-01-000 / NRA501000

 

Edwards E2M18 Agilent NRA5-01-000


The Edwards E2M18 / NRA0510000 vacuum pumps are direct drive, sliding vane pumps. The E2M18 is a dual-stage vaccuum pump.

The Edwards E2M18 pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

This pump has been rebuilt with Hydrocarbon oil

The Edwards single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gasballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminium alloy baseplate on rubber pads.

When you use the pump with high vapour throughputs, you should use the gas-ballast facility to prevent condensation of the vapours inside the pump. The condensates will contaminate the oil, will cause performance to deteriorate and may cause corrosion of the pump mechanism.

 

Edwards Agilent 208 V E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Agilent Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: In Stock
Item#: PN06455 Mfr Part#: A36315920 Manufacturer: Edwards Vacuum
Price upon request

Fuly Rebuilt Edwards E2M18 Vacuum Pump, Dual Stage Rotary Vane Pump, 220 VAC, A36315920

 

Edwards E2M18 Overview:


Edwards E2M18 A36315920 is a single stage oil sealed rotary vane pump which has a pressurized oil system that lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents oil suckback unless the gas ballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow either gravity oil drain or pressure oil drain.

 

Edwards E2M18 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M18 Dimensions:


Edwards E1M18, A34324904, Dimensions


Click Here for Edwards E1M18 and E2M18 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured Out of Stock
Item#: PN06456 Mfr Part#: A373-24-903 Manufacturer: Edwards Vacuum
Price upon request

Fuly Rebuilt Edwards E2M28 Rotary Vane Vacuum Pump, Hydrocarbon Oil, Dual Stage, 220-240 VAC, A37315903

 

Edwards E2M28 Overview:


The E2M28 Rotary Vane Pump is a two-stage, direct drive, sliding vane pump. The pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The motors are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

The single-phase motors have a thermal overload device. When the motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

An oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gas-ballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminum alloy baseplate on rubber pads.

 

Edwards E2M28 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M28 Dimensions:


Edwards E2M28, A37315903, Dimensions


Click Here for Edwards E2M28 and E2M30 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured Out of Stock
Item#: PN07042 Mfr Part#: A373-24-904 Manufacturer: Edwards Vacuum
PRICE: $6,920.00
WEB SAVINGS: $2,470.00
YOU PAY: $4,450.00

Fuly Rebuilt Edwards E2M28 Rotary Vane Vacuum Pump, Hydrocarbon Oil, Dual Stage, 100-105 VAC / 200-210 VAC, A37324904, Agilent G1969-80208

 

Edwards E2M28 Overview:


The E2M28 A373-24-904 Rotary Vane Pump is a two-stage, direct drive, sliding vane pump. The pump is oil-sealed and designed for reliable, long-term operation in both laboratory and industrial environments. The pump is a free-standing unit. The drive is provided through a flexible coupling by a single-phase or three-phase (four pole) motor.

The Edwards E2M28 electric motor are totally enclosed and are cooled by the motor-cooling fan which directs air along the motor fins.

The single-phase motors have a thermal overload device. When the E2M28 motor is too hot, the thermal overload device switches off the pump. The thermal overload device has an automatic reset; when the motor cools down, the device resets and the motor will restart. The single phase motors have an on/off switch.

Edwards E2M28 oil pressure system lubricates the pump shaft bearing surfaces and rotor sealing faces. The pump has an oil distribution valve which prevents discharge of oil to the pump interior (suckback) after the pump stops. The pumping chambers are air-tight, so this arrangement prevents air suckback unless the gas-ballast valve is open.

You can inspect the level and condition of oil in the oil box reservoir through the oil sight-glass. An oil filler-plug is fitted to the top of the oil box. The pump has an oil drain-plug to allow gravity oil drain.

The pump has an inlet-port, outlet nozzle and gas-ballast control. The pump is mounted on an aluminum alloy baseplate on rubber pads.

Agilent vacuum pump, 208 V (200 to 220 VAC), 50/60 Hz, TOF 62XX series, triple quad 64XX series, and Q-TOF 65XX series, models 62XX, G6410A/B, G6430A, G6460A, G6510A, G6520B, G6530A, G6538A, and G6540A

 

Edwards E2M28 Applications:


  • Gas Analysis
  • Leak Detection
  • Mass Spectrometers
  • Electron Microscopes
  • Centrifuges
  • Sterilization
  • Electron Tubes
  • Lamps
  • Air Conditioning
  • Drying
  • Ion Implantation
  • Cryogenics
  • Gas Recovery
  • Oxygen Pumping

 

Edwards E2M28 Dimensions:


Edwards E2M28, A37315903, Dimensions


Click Here for Edwards E2M28 and E2M30 Manual


A&J Vacuum also repair / rebuild and service all Edwards E1M18, E2M18, E2M18, E2M28 Series  Vacuum Pumps  along with all other Edwards  Turbo Pumps, Edwards Dry Pumps, Edwards Scroll Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854


Condition: Remanufactured Out of Stock
Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.