phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560
Item#: PN22110 Mfr Part#: PTL02001 Manufacturer: Pfeiffer Vacuum
Condition: Remanufactured Call us for Availability
Remanufactured Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560

Features:
  • Smallest detectable leak rate
  • 4He <5×10-12 mbar l/s
  • Filaments 2 (Iridium yttrated)
  • Detectable gases 4He, 3He, H2

Price upon request
Item#: PN22110 Mfr Part#: PTL02001
Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560
Item#: PN22110 Mfr Part#: PTL02001 Manufacturer: Pfeiffer Vacuum

Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560

 

Pfeiffer HLT 560 Overview & Features:


The Pfeiffer HLT560 SmartTest Helium Leak Detectors PTL02001 are microprocessor-controller leak detecting instruments. All the processes in the instrument are controlled automatically.

  • Rugged, dependable helium leak detector.
  • For a mains voltage of 120 V, 60 Hz
  • With 5.1 m3/h UNO5 Rotary Vane Pump
  • Very easy operation to achieve precise measuring results
  • Wireless remote control optional, distance up to 100 m as well as data logging to USB stick
  • Durable and industry-tested mass spectrometer
  • Integrated test leak
  • Bypass option for large test items
  • For sniffer and vacuum leak detection
  • Simple maintenance - low cost of ownership

 

Helium Leak Detector – The clever and modular Solution. Simple Operation. Top Performance.


Leak Detection Methods


When searching for leaks with the SmartTest the test gas entering or escaping
through leaks in the sample is detected.
For gas to flow through a leak a pressure difference between the inside and outside
of the sample is necessary. For this either excess pressure or vacuum pressure is
generated inside the sample.


Vacuum method


In the vacuum method test gas is blown against the wall of the evacuated sample
from the atmosphere side. It enters the sample at leaks and is fed to the leak
detector.
The sample must be vacuum pressure-proof.
The sensitivity stages
counterflow ⇒ Twin-Flow™ low ⇒ Twin-Flow™ high
are run through.
The detection limit is lower than in the sniffing method. The helium concentration
at the leak must be known in order to quantify the leak. The state of equilibrium
must be waited for.

 

Sniffing method


In the sniffing method the test gas escaping from leaks in the sample into the
atmosphere is detected.
The sample must withstand the applied test pressure.
In operation with the sniffing probe a constant gas flow is sucked in from the
atmosphere. The helium proportion of the air (5.2 ppm) causes a leak rate display
of approx. 1×10-6 mbar l/s which can be eliminated by the ZERO function.
To detect a leak, the sniffing probe is applied to the points of the sample under
helium overpressure which are suspected of leaking. An increased leak rate value
indicates an increased concentration of helium and therefore a leak. The higher the
pressure and the helium concentration in the sample, the smaller the leaks which
can be detected.
The sensitivity stages
counterflow ⇒ Twin-Flow™ low
are run through.
The detection sensitivity and the quantifiability of the leak rate are less favourable
than in the vacuum pressure leak detection.

With its modular design and it's new wireless remote control RC 500 WL, the SmartTest offers the perfect solution for vacuum leak detection. Fast, reliable results, lowest detectable leak rates and short recovery time are what characterize the SmartTest and make it such a powerful and dependable product.

Utmost sensitivity in identifying even the smallest leaks. Quantification of the leaks. Outstanding reproducibility of the measurement. Helium test gas is non-toxic and non-flammable. Short measurement times

 

Pfeiffer HLT 560 Dimensions:


Pfeiffer HLT 560 Leak Detector Dimension, PTL02001


Click Here for Pfeiffer HLT 560  Manual


A&J Vacuum Services offers full repair/service of Pfeiffer HLT 560 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560

 

Pfeiffer HLT 560 Technical Data:


Ambient temperature 10-35 °C
Cold start to ready 3 min
Detectable gases 4He, 3He, H2
Flange (in) DN 25 ISO-KF
Inlet pressure max. 25 mbar
Input: Analog ActiveLine vacuum transmitter
Input: Digital Start/Stop, Vent, Cero, Calibration, Bypass detection
Interface RS-232-C, RS-485
Leak rate display 10-12 - 1 mbar l/s
OuTPU t: Analog Leakage rate signal 2 x 0-10 V, lin/log
OuTPU t: Digital Ready to start, Ready to measure, Leak,
Error, Bypass valve, Calibration acknowledge
Power consumption 300 VA
Pumping speed for He 2.5 l/s
Pumping time to ready: 0.5 l test volume no
Pumping time to ready: 0.5 l test volume 1 s
Pumping time to ready: 100 l test volume no
Pumping time to ready: 100 l test volume 1300 s
Pumping time to ready: 10 l test volume no
Pumping time to ready: 10 l test volume 125 s
Relay: Switching capacity 2 x 230 V AC
Relay: Switching current 3 A
Response time 0.5 s
Roughing pump Yes
Roughing pump Single-stage rotary vane pump, oil
sealed. Volume flow rate 4 m³/h at 50 Hz, 5.1 m³/h at 60 Hz
Smallest detectable leak rate for He
(according AVS 2.1)
< 5·10-12 mbar l/s
Sniffer probe, detectable leak rate < 5·10-8 mbar l/s
Supply no
Supply 120 V, 60 Hz
Test method Vacuum and sniffing leak detection
Weight 44 kg

Click Here for Pfeiffer HLT 560  Manual


A&J Vacuum Services offers full repair/service of Pfeiffer HLT 560 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Vacuum Smart Test HLT 570, HLT 550, HLT 560, HLT 572 Leak Detector
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560
Item#: PN22110 Mfr Part#: PTL02001 Manufacturer: Pfeiffer Vacuum

Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560

 

Pfeiffer HLT 560 Overview & Features:


The Pfeiffer HLT560 SmartTest Helium Leak Detectors PTL02001 are microprocessor-controller leak detecting instruments. All the processes in the instrument are controlled automatically.

  • Rugged, dependable helium leak detector.
  • For a mains voltage of 120 V, 60 Hz
  • With 5.1 m3/h UNO5 Rotary Vane Pump
  • Very easy operation to achieve precise measuring results
  • Wireless remote control optional, distance up to 100 m as well as data logging to USB stick
  • Durable and industry-tested mass spectrometer
  • Integrated test leak
  • Bypass option for large test items
  • For sniffer and vacuum leak detection
  • Simple maintenance - low cost of ownership

 

Helium Leak Detector – The clever and modular Solution. Simple Operation. Top Performance.


Leak Detection Methods


When searching for leaks with the SmartTest the test gas entering or escaping
through leaks in the sample is detected.
For gas to flow through a leak a pressure difference between the inside and outside
of the sample is necessary. For this either excess pressure or vacuum pressure is
generated inside the sample.


Vacuum method


In the vacuum method test gas is blown against the wall of the evacuated sample
from the atmosphere side. It enters the sample at leaks and is fed to the leak
detector.
The sample must be vacuum pressure-proof.
The sensitivity stages
counterflow ⇒ Twin-Flow™ low ⇒ Twin-Flow™ high
are run through.
The detection limit is lower than in the sniffing method. The helium concentration
at the leak must be known in order to quantify the leak. The state of equilibrium
must be waited for.

 

Sniffing method


In the sniffing method the test gas escaping from leaks in the sample into the
atmosphere is detected.
The sample must withstand the applied test pressure.
In operation with the sniffing probe a constant gas flow is sucked in from the
atmosphere. The helium proportion of the air (5.2 ppm) causes a leak rate display
of approx. 1×10-6 mbar l/s which can be eliminated by the ZERO function.
To detect a leak, the sniffing probe is applied to the points of the sample under
helium overpressure which are suspected of leaking. An increased leak rate value
indicates an increased concentration of helium and therefore a leak. The higher the
pressure and the helium concentration in the sample, the smaller the leaks which
can be detected.
The sensitivity stages
counterflow ⇒ Twin-Flow™ low
are run through.
The detection sensitivity and the quantifiability of the leak rate are less favourable
than in the vacuum pressure leak detection.

With its modular design and it's new wireless remote control RC 500 WL, the SmartTest offers the perfect solution for vacuum leak detection. Fast, reliable results, lowest detectable leak rates and short recovery time are what characterize the SmartTest and make it such a powerful and dependable product.

Utmost sensitivity in identifying even the smallest leaks. Quantification of the leaks. Outstanding reproducibility of the measurement. Helium test gas is non-toxic and non-flammable. Short measurement times

 

Pfeiffer HLT 560 Dimensions:


Pfeiffer HLT 560 Leak Detector Dimension, PTL02001


Click Here for Pfeiffer HLT 560  Manual


A&J Vacuum Services offers full repair/service of Pfeiffer HLT 560 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer HLT560 Helium Leak Detector, 120 VAC / 60 Hz, PTL02001,Like New, HLT 560

 

Pfeiffer HLT 560 Technical Data:


Ambient temperature 10-35 °C
Cold start to ready 3 min
Detectable gases 4He, 3He, H2
Flange (in) DN 25 ISO-KF
Inlet pressure max. 25 mbar
Input: Analog ActiveLine vacuum transmitter
Input: Digital Start/Stop, Vent, Cero, Calibration, Bypass detection
Interface RS-232-C, RS-485
Leak rate display 10-12 - 1 mbar l/s
OuTPU t: Analog Leakage rate signal 2 x 0-10 V, lin/log
OuTPU t: Digital Ready to start, Ready to measure, Leak,
Error, Bypass valve, Calibration acknowledge
Power consumption 300 VA
Pumping speed for He 2.5 l/s
Pumping time to ready: 0.5 l test volume no
Pumping time to ready: 0.5 l test volume 1 s
Pumping time to ready: 100 l test volume no
Pumping time to ready: 100 l test volume 1300 s
Pumping time to ready: 10 l test volume no
Pumping time to ready: 10 l test volume 125 s
Relay: Switching capacity 2 x 230 V AC
Relay: Switching current 3 A
Response time 0.5 s
Roughing pump Yes
Roughing pump Single-stage rotary vane pump, oil
sealed. Volume flow rate 4 m³/h at 50 Hz, 5.1 m³/h at 60 Hz
Smallest detectable leak rate for He
(according AVS 2.1)
< 5·10-12 mbar l/s
Sniffer probe, detectable leak rate < 5·10-8 mbar l/s
Supply no
Supply 120 V, 60 Hz
Test method Vacuum and sniffing leak detection
Weight 44 kg

Click Here for Pfeiffer HLT 560  Manual


A&J Vacuum Services offers full repair/service of Pfeiffer HLT 560 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Vacuum Smart Test HLT 570, HLT 550, HLT 560, HLT 572 Leak Detector
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.