Shopping Cart ( )

Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

Condition: Demo
Out of Stock
Item#:PN00121
Mfr Part#:PTL02161
Manufacturer:Pfeiffer Vacuum
Demo Demo Unit Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Features:
  • Like New !!!
  • Best in the Class
  • Complete Dry Package
6 months warranty

Demo Unit Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

 

Pfeiffer HLT 572 Overview & Features:


  • Rugged, dependable helium leak detector, absolutely oil-free
  • For a mains voltage of 100-120 V, 50/60 Hz
  • HLT 572 with cart and 28 m3/h dry pump
  • Very easy operation to achieve precise measuring results
  • Analog and digital inputs and outputs for industrial use
  • Durable and industry-tested mass spectrometer
  • Integrated test leak
  • Bypass option for large test items
  • For sniffer and vacuum leak detection
  • Simple maintenance - low cost of ownership

  • Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
  • Relay: Switching current 3 A
  • Relay: Switching capacity 2x 230 VAC
  • Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge
  • Output: Analog Leak rate signal 2x 0-10 V, lin/log
  • Weight 140 kg Interface RS-232-C, RS-485
  • Power consumption 900 VA
  • Ambient temperature - ºC
  • Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar
  • Pumping time to ready: 100 l test volume 160 s
  • Pumping time to ready: 10 l test volume 16 s
  • Pumping time to ready: 0.5 l test volume 1 s
  • Response time 0,5 s
  • Cold start to ready 3 min
  • Leak rate display 10-12 - 1 mbar l/s
  • Detectable gases 4He, 3He, H2
  • Sniffer probe, detectable leak rate 5·10-8 mbar l/s
  • Smallest detectable leak rate for 4He 5·10-12 mbar l/s

A&J Vacuum Services offers full repair/service of Pfeiffer HLT 572 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Demo Unit Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

 

Pfeiffer HLT 572 Technical Data:


Smallest detectable leak rate for 4He 5·10-12 mbar l/s

Sniffer probe, detectable leak rate 5·10-8 mbar l/s

Detectable gases 4He, 3He, H2

Leak rate display 10-12 - 1 mbar l/s

Cold start to ready 3 min

Response time 0.5 s

Pumping time to ready: 0.5 l test volume 1 s

Pumping time to ready: 10 l test volume 16 s

Pumping time to ready: 100 l test volume 160 s

Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar

Ambient temperature - ºC

Power consumption 900 VA

Weight 140 kg Interface RS-232-C, RS-485

Output: Analog Leak rate signal 2x 0-10 V, lin/log

Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge

Relay: Switching capacity 2x 230 VAC

Relay: Switching current 3 A

Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161


A&J Vacuum Services offers full repair/service of Pfeiffer HLT 572 SmartTest Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Vacuum Smart Test HLT 570, HLT 550, HLT 560, HLT 572 Leak Detector
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.