Shopping Cart ( )

Leybold UL200 Helium Leak Detector Bench top unit, 115 VAC to be used with external Roughing pump. UL 200

Condition: Remanufactured
Call us for Availability
Item#:PN18493
Mfr Part#:18493
Manufacturer:Leybold
Remanufactured Leybold UL 200 Helium Leak Detector, bench top unit to be used with external Roughing pump (Not Included)
Features:
  • Mass Spectometer - 180* sector field
  • Vacuum Mode <5-10-11 mbar l/s-1
  • Sniffer Mode <1-10-7 mbar l/s-1
  • Detectable masses 2, 3and 4
90 days warranty

Leybold UL 200 Helium Leak Detector, bench top unit to be used with external Roughing pump (Not Included)

 

Leybold UL 200 Overview:


Leybold UL200 Helium Leak Detector, bench top unit to be used with external Roughing pump (Not Included)

3 CFM Roughing Pump Required

The Leybold Ultratest UL200 is a helium leak detector. This Instrument may be used to locate and quantify leaks in test samples.

The UL 200 is capable of detecting and quantifying helium test gas flowing into a test sample having a leak by means of selective mass spectometer. It's operation is based on the counter flow principle, i.e. inflowing helium diffuses against the gas flow being pumped by the turbomolecular pump into the mass spectometerwhereas heavier gases are held back.

The Backing Pump (not Included) generates the forepressure required for operation of the turbomolecular pump.

 


A&J Vacuum Services offers full repair/service of Leybold UL 200, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Leybold UL 200 Helium Leak Detector, bench top unit to be used with external Roughing pump (Not Included)

 

Leybold UL 200 Technical Data:


Lowest detectable helium leak rate;

Vacuum Mode <5-10-11 mbar l/s-1

Lowest detectable helium leak rate;

Sniffer Mode    <1-10-7 mbar l/s-1

Measurment range  9 decades
Detectable masses  2, 3and 4
Mass Spectometer 180* sector field
Ion Source 2 cathodes; iridium / yttrium
Max. inlet pressure 3 mbar
Pumping Speed at the inlet S <1 l/s-1 Fine
Test Port DN-25-KF
Main Voltage (fixed) 110-120 V 60 Hz

 


A&J Vacuum Services offers full repair/service of Leybold UL 200, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Item#:PN20442
Mfr Part#:20099026
Condition: In Stock New
In Stock
$129.00
Item#:PN20443
Mfr Part#:200001366
Condition: In Stock New
In Stock
$117.00
Get started with your repair: 

We can have a repair estimate ready for your equipment within the hour of submission.

Request a repair estimate

Start your equipment repair process by creating a Service RMA.

Generate Service RMA

High quality service guaranteed

A&J Vacuum Services provides repairs on all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair and Mass Spectrometer repair. Our highly trained technicians will deliver the highest quality service and satisfaction.

We operate at our own full service repair facility which allows us to quickly and economically perform all repairs in a timely manner. Our advandced machinery enables us to handle all facets of the service and repair process. AJVS utilizes industry standard vibration analysis equipment and advanced testing equipment to troubleshoot and minimize all equipment failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

AJVS repair process:
Repair Steps
  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly of the pump, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and log pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10 -Mbar l/s. Vibrations are analyzed and test data is digitally recorded.
We can repair your:
 
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
Deals & Promotions
Contact
A&J Vacuum Services 16 Somerset Place,
Clifton, NJ 07012
Customer Service Phone: 973-249-0854,
Fax: 973-249-0855
Service Hours 8:00am to 5:00pm,
Monday thru Friday EST
@ A&J Vacuum Services, Inc. 2000-2026. All Rights Reserved.
All trademarks, trade names or logons mentioned or used are the property of their respective owners.