Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000
Item#: PN00838 Mfr Part#: A13305000 Manufacturer: Edwards Vacuum
Condition: New In Stock
New Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000

Features:
  • Ambient operating temperature range 0 to 50 °C
  • Maximum internal pressure 1 bar absolute, 1 x 105 Pa
  • Mass: 1 kg
  • Sorbent charge 0.07 kg

PRICE: $890.00
WEB SAVINGS: $15.00
YOU PAY: $875.00
Item#: PN00838 Mfr Part#: A13305000
Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000
Item#: PN00838 Mfr Part#: A13305000 Manufacturer: Edwards Vacuum

Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000

 

Edwards FL20K Overview:


The FL20K foreline trap has been developed for use in clean pumping systems, to prevent the back-migration of rotary pump oil mist into the system.
 
The FL20K is most useful with two-stage rotary pumps, operating below 1 mbar. To maximize sorbent life, install the FL20K near the vacuum system. In common with other types of sorbent, activated alumina absorbs water. This does not affect the oil vapor trapping properties but may tend to prolong the roughing time on successive pump downs. To minimize vapor absorption, we recommend you fit a valved by-pass line.
 
The trap body is made of aluminum and is fitted with a removable basket containing the sorbent.

 

Edwards FL20K Features:


  • Exceptional trapping properties for oil mist (99.7%)
  • A very long life before it is saturated
  • Can be rejuvenated by baking the basket containing the sorbent for
    2 hours at 250 °C - 300 °C.

 

Edwards FL20K Dimensions:


Edwards FL20K Foreline Inlet Trap, FL 20K,  A13305000

 


A&J Vacuum Services offers full repair/service of Edwards Pumps, along with all other brands offered on our website. AJVS also services Edwards Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000

 

Edwards FL20K Technical Data: 13305000


Ambient operating temperature range 0 to 50 °C
Leak tightness (1 bar (1 x 105 Pa) differential): 1 x 10-6 mbar ls-1, 1 x 10-4 Pa ls-1
Maximum internal pressure 1 bar absolute, 1 x 105 Pa
Mass 1 kg
Sorbent charge 0.07 kg

A&J Vacuum Services offers full repair/service of Edwards Pumps, along with all other brands offered on our website. AJVS also services Edwards Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000
Item#: PN00838 Mfr Part#: A13305000 Manufacturer: Edwards Vacuum

Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000

 

Edwards FL20K Overview:


The FL20K foreline trap has been developed for use in clean pumping systems, to prevent the back-migration of rotary pump oil mist into the system.
 
The FL20K is most useful with two-stage rotary pumps, operating below 1 mbar. To maximize sorbent life, install the FL20K near the vacuum system. In common with other types of sorbent, activated alumina absorbs water. This does not affect the oil vapor trapping properties but may tend to prolong the roughing time on successive pump downs. To minimize vapor absorption, we recommend you fit a valved by-pass line.
 
The trap body is made of aluminum and is fitted with a removable basket containing the sorbent.

 

Edwards FL20K Features:


  • Exceptional trapping properties for oil mist (99.7%)
  • A very long life before it is saturated
  • Can be rejuvenated by baking the basket containing the sorbent for
    2 hours at 250 °C - 300 °C.

 

Edwards FL20K Dimensions:


Edwards FL20K Foreline Inlet Trap, FL 20K,  A13305000

 


A&J Vacuum Services offers full repair/service of Edwards Pumps, along with all other brands offered on our website. AJVS also services Edwards Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards FL20K Foreline Inlet Trap, FL 20K, A13305000

 

Edwards FL20K Technical Data: 13305000


Ambient operating temperature range 0 to 50 °C
Leak tightness (1 bar (1 x 105 Pa) differential): 1 x 10-6 mbar ls-1, 1 x 10-4 Pa ls-1
Maximum internal pressure 1 bar absolute, 1 x 105 Pa
Mass 1 kg
Sorbent charge 0.07 kg

A&J Vacuum Services offers full repair/service of Edwards Pumps, along with all other brands offered on our website. AJVS also services Edwards Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST