Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701
Item#: PN43316 Mfr Part#: 2000049386 / 111701 Manufacturer: Pfeiffer-Vacuum
Condition:
New
In Stock
New Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701

Features:
  • Capacitors (300μF, 25μF) + relay
  • OEM Part
  • For Pascal Series Pump Motors
  • P/N 111701

PRICE: $310.00
WEB SAVINGS: $15.00
YOU PAY: $295.00
Tariff charges are calculated during checkout
Item#: PN43316 Mfr Part#: 2000049386 / 111701
Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701
Item#: PN43316 Mfr Part#: 2000049386 / 111701 Manufacturer: Pfeiffer-Vacuum

Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701

 

For safety reasons, the manufacturer recommends that single-phase motors be properly maintained. Although there is only an extremely small risk of flammability, you are advised to replace the capacitors and/or the motor in the following cases:

Single-phase motor with ID number < 110000 :

• replace the motor immediately by ordering a new motor.

• then, every 5 years, replace the capacitors and the relays by ordering a kit.

 

Single-phase motor with ID number > 110000 :

• every 5 years, replace the capacitors and the relays by ordering a capacitor kit.

• after 15 years, replace the motor by ordering a new motor.

 

The procedure for replacing capacitors and relays is provided with the capacitor kit.

 

A&J Vacuum services and repairs Pfeiffer Adixen 2005-2021 SD Pascal, along with all other Pfeiffer Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701

 

For safety reasons, the manufacturer recommends that single-phase motors be properly maintained. Although there is only an extremely small risk of flammability, you are advised to replace the capacitors and/or the motor in the following cases:

Single-phase motor with ID number < 110000 :

• replace the motor immediately by ordering a new motor.

• then, every 5 years, replace the capacitors and the relays by ordering a kit.

 

Single-phase motor with ID number > 110000 :

• every 5 years, replace the capacitors and the relays by ordering a capacitor kit.

• after 15 years, replace the motor by ordering a new motor.

 

The procedure for replacing capacitors and relays is provided with the capacitor kit.

 

A&J Vacuum services and repairs Pfeiffer Adixen 2005-2021 SD Pascal, along with all other Pfeiffer Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701
Item#: PN43316 Mfr Part#: 2000049386 / 111701 Manufacturer: Pfeiffer-Vacuum

Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701

 

For safety reasons, the manufacturer recommends that single-phase motors be properly maintained. Although there is only an extremely small risk of flammability, you are advised to replace the capacitors and/or the motor in the following cases:

Single-phase motor with ID number < 110000 :

• replace the motor immediately by ordering a new motor.

• then, every 5 years, replace the capacitors and the relays by ordering a kit.

 

Single-phase motor with ID number > 110000 :

• every 5 years, replace the capacitors and the relays by ordering a capacitor kit.

• after 15 years, replace the motor by ordering a new motor.

 

The procedure for replacing capacitors and relays is provided with the capacitor kit.

 

A&J Vacuum services and repairs Pfeiffer Adixen 2005-2021 SD Pascal, along with all other Pfeiffer Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Adixen Capacitor kit with Relay for Pascal Series single phase motors (300μF, 25μF), 2000049386 / 111701

 

For safety reasons, the manufacturer recommends that single-phase motors be properly maintained. Although there is only an extremely small risk of flammability, you are advised to replace the capacitors and/or the motor in the following cases:

Single-phase motor with ID number < 110000 :

• replace the motor immediately by ordering a new motor.

• then, every 5 years, replace the capacitors and the relays by ordering a kit.

 

Single-phase motor with ID number > 110000 :

• every 5 years, replace the capacitors and the relays by ordering a capacitor kit.

• after 15 years, replace the motor by ordering a new motor.

 

The procedure for replacing capacitors and relays is provided with the capacitor kit.

 

A&J Vacuum services and repairs Pfeiffer Adixen 2005-2021 SD Pascal, along with all other Pfeiffer Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.