Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Item#: PN00121 Mfr Part#: PTL02161 Manufacturer: Pfeiffer-Vacuum
Condition: Demo Out of Stock
Demo Demo Unit Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

Features:
  • Like New !!!
  • Best in the Class
  • Complete Dry Package

PRICE: $43,250.00
$25,950.00
Item#: PN00121 Mfr Part#: PTL02161
Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Item#: PN00121 Mfr Part#: PTL02161 Manufacturer: Pfeiffer-Vacuum
  • Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

  • Rugged, dependable helium leak detector, absolutely oil-free
  • For a mains voltage of 100-120 V, 50/60 Hz
  • HLT 572 with cart and 28 m3/h dry pump
  • Very easy operation to achieve precise measuring results
  • Analog and digital inputs and outputs for industrial use
  • Durable and industry-tested mass spectrometer
  • Integrated test leak
  • Bypass option for large test items
  • For sniffer and vacuum leak detection
  • Simple maintenance - low cost of ownership
  • Smallest detectable leak rate for 4He 5·10-12 mbar l/s
  • Sniffer probe, detectable leak rate 5·10-8 mbar l/s
  • Detectable gases 4He, 3He, H2
  • Leak rate display 10-12 - 1 mbar l/s
  • Cold start to ready 3 min
  • Response time 0,5 s
  • Pumping time to ready: 0.5 l test volume 1 s
  • Pumping time to ready: 10 l test volume 16 s
  • Pumping time to ready: 100 l test volume 160 s
  • Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar
  • Ambient temperature - ºC
  • Power consumption 900 VA
  • Weight 140 kg Interface RS-232-C, RS-485
  • Output: Analog Leak rate signal 2x 0-10 V, lin/log
  • Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge
  • Relay: Switching capacity 2x 230 VAC
  • Relay: Switching current 3 A
  • Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

A&J Vacuum also repair / rebuild and service Pfeiffer HLT 550, HLT 560, HLT 570 and HLT 572 Helium Leak Detectors along with all other PfeifferTurbo pumps and Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

  • Smallest detectable leak rate for 4He 5·10-12 mbar l/s
  • Sniffer probe, detectable leak rate 5·10-8 mbar l/s
  • Detectable gases 4He, 3He, H2
  • Leak rate display 10-12 - 1 mbar l/s
  • Cold start to ready 3 min
  • Response time 0,5 s
  • Pumping time to ready: 0.5 l test volume 1 s
  • Pumping time to ready: 10 l test volume 16 s
  • Pumping time to ready: 100 l test volume 160 s
  • Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar
  • Ambient temperature - ºC
  • Power consumption 900 VA
  • Weight 140 kg Interface RS-232-C, RS-485
  • Output: Analog Leak rate signal 2x 0-10 V, lin/log
  • Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge
  • Relay: Switching capacity 2x 230 VAC
  • Relay: Switching current 3 A
  • Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Pfeiffer Vacuum Smart Test HLT 570, HLT 550, HLT 560, HLT 572 Leak Detector
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Item#: PN00121 Mfr Part#: PTL02161 Manufacturer: Pfeiffer-Vacuum
  • Pfeiffer HLT572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

  • Rugged, dependable helium leak detector, absolutely oil-free
  • For a mains voltage of 100-120 V, 50/60 Hz
  • HLT 572 with cart and 28 m3/h dry pump
  • Very easy operation to achieve precise measuring results
  • Analog and digital inputs and outputs for industrial use
  • Durable and industry-tested mass spectrometer
  • Integrated test leak
  • Bypass option for large test items
  • For sniffer and vacuum leak detection
  • Simple maintenance - low cost of ownership
  • Smallest detectable leak rate for 4He 5·10-12 mbar l/s
  • Sniffer probe, detectable leak rate 5·10-8 mbar l/s
  • Detectable gases 4He, 3He, H2
  • Leak rate display 10-12 - 1 mbar l/s
  • Cold start to ready 3 min
  • Response time 0,5 s
  • Pumping time to ready: 0.5 l test volume 1 s
  • Pumping time to ready: 10 l test volume 16 s
  • Pumping time to ready: 100 l test volume 160 s
  • Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar
  • Ambient temperature - ºC
  • Power consumption 900 VA
  • Weight 140 kg Interface RS-232-C, RS-485
  • Output: Analog Leak rate signal 2x 0-10 V, lin/log
  • Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge
  • Relay: Switching capacity 2x 230 VAC
  • Relay: Switching current 3 A
  • Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161

A&J Vacuum also repair / rebuild and service Pfeiffer HLT 550, HLT 560, HLT 570 and HLT 572 Helium Leak Detectors along with all other PfeifferTurbo pumps and Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

  • Smallest detectable leak rate for 4He 5·10-12 mbar l/s
  • Sniffer probe, detectable leak rate 5·10-8 mbar l/s
  • Detectable gases 4He, 3He, H2
  • Leak rate display 10-12 - 1 mbar l/s
  • Cold start to ready 3 min
  • Response time 0,5 s
  • Pumping time to ready: 0.5 l test volume 1 s
  • Pumping time to ready: 10 l test volume 16 s
  • Pumping time to ready: 100 l test volume 160 s
  • Pumping speed: for He 2,5 l/s Inlet pressure max. 25 mbar
  • Ambient temperature - ºC
  • Power consumption 900 VA
  • Weight 140 kg Interface RS-232-C, RS-485
  • Output: Analog Leak rate signal 2x 0-10 V, lin/log
  • Output: Digital Ready to pump, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge
  • Relay: Switching capacity 2x 230 VAC
  • Relay: Switching current 3 A
  • Pfeiffer HLT 572 SmartTest Helium Leak Detector with Cart and XtraDry Pump, 120 V, 50/60 Hz, PTL02161
Pfeiffer Vacuum Smart Test HLT 570, HLT 550, HLT 560, HLT 572 Leak Detector
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.