Edwards EMF 20 Oil Mist Filters are used to separate and trap oil mist and odors discharged with the exhaust from oil sealed rotary vacuum pumps. The Oil Mist Filters have two-part injection molded plastic bodies which contain a fiber composite oil mist filter and an activated carbon odor filter.
Exhaust gases from the pump travel upwards to the center of the Oil Mist Filter and through the filter element to the outside. Oil droplets that are trapped by the fiber composite element travel down the filter and collect in a reservoir in the base of the Oil Mist Filter.
Replacement Filter Elements: A22304077, and A22304199
Click Here for Edwards EMF 20 Manual
A&J Vacuum Services offers full repair/service of Edwards, along with all other brands offered on our website. AJVS also services Edwards rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Rated Flow: | 20 m3h-1 |
Maximum Back Pressure: | 12 psig |
Relief Pressure: | 20 psig |
Odor Filter Element: | Activated carbon |
Mist Filter Element: | Epoxy impregnated borosilicate glass fibre |
Outlet Flange: | NW 25 |
Inlet Flange: | NW 25 |
Ambient temperature range (storage) | -10 to 90 °C |
Ambient temperature range (operation) | 0 to 45 °C |
Weight: | .5 kg / 1.1 lbs |
Click Here for Edwards EMF 20 Manual
A&J Vacuum Services offers full repair/service of Edwards, along with all other brands offered on our website. AJVS also services Edwards rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Edwards EMF 20 Oil Mist Filters are used to separate and trap oil mist and odors discharged with the exhaust from oil sealed rotary vacuum pumps. The Oil Mist Filters have two-part injection molded plastic bodies which contain a fiber composite oil mist filter and an activated carbon odor filter.
Exhaust gases from the pump travel upwards to the center of the Oil Mist Filter and through the filter element to the outside. Oil droplets that are trapped by the fiber composite element travel down the filter and collect in a reservoir in the base of the Oil Mist Filter.
Replacement Filter Elements: A22304077, and A22304199
Click Here for Edwards EMF 20 Manual
A&J Vacuum Services offers full repair/service of Edwards, along with all other brands offered on our website. AJVS also services Edwards rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Rated Flow: | 20 m3h-1 |
Maximum Back Pressure: | 12 psig |
Relief Pressure: | 20 psig |
Odor Filter Element: | Activated carbon |
Mist Filter Element: | Epoxy impregnated borosilicate glass fibre |
Outlet Flange: | NW 25 |
Inlet Flange: | NW 25 |
Ambient temperature range (storage) | -10 to 90 °C |
Ambient temperature range (operation) | 0 to 45 °C |
Weight: | .5 kg / 1.1 lbs |
Click Here for Edwards EMF 20 Manual
A&J Vacuum Services offers full repair/service of Edwards, along with all other brands offered on our website. AJVS also services Edwards rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.