phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer Adixen Oil Mist Eliminator for ASM 142, ASM 182, and ASM 340 WET Helium Leak Detectors, 121494
Item#: PN22410 Mfr Part#: 121494 Manufacturer: Pfeiffer Vacuum
Condition: New
New Pfeiffer Adixen Oil Mist Eliminator for ASM-142, ASM-182, and ASM-340 WET Helium Leak Detectors, 121494

Features:
  • OEM replacement for the 107348 oil mist eliminator
  • P/N 121494
  • for ASM Series Leak Detectors

PRICE: $550.00
WEB SAVINGS: $51.00
YOU PAY: $499.00
Item#: PN22410 Mfr Part#: 121494
Pfeiffer Adixen Oil Mist Eliminator for ASM 142, ASM 182, and ASM 340 WET Helium Leak Detectors, 121494
Item#: PN22410 Mfr Part#: 121494 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen Oil Mist Eliminator for ASM142, ASM182, and ASM340 WET Helium Leak Detectors, 121494


The Pfeiffer Adixen 121494 oil mist eliminator is an OEM replacement for Pfeiffer part number 107348. 

121494 is the recommended oil mist eliminator for ASM series leak detectors such as:

  • ASM 142
  • ASM 182
  • ASM 340

 


Replacement of the internal Oil Mist Eliminator

  • 5 mm Allen key supplied in the maintenance kit
  •  Oil mist eliminator: (see 9)Procedure
  • Make sure that the detector is off (circuit breaker on 0, control panel switched offand mains power cable disconnected).
  • Remove the storage tank (2 screws + washers).
  • Loosen the screw (2) of the oil mist eliminator's mounting bracket.
  • Remove the fixing clamp of the hose (3) and then the hose.
  • Replace the oil mist eliminator.

New Pfeiffer Adixen Oil Mist Eliminator for ASM 142, ASM 182, and ASM 340 WET  Helium Leak Detectors, 121494


 

Replacement of the internal Oil Mist Eliminator

 

  • 5 mm Allen key supplied in the maintenance kit
  •  Oil mist eliminator: (see 9)Procedure
  • Make sure that the detector is off (circuit breaker on 0, control panel switched offand mains power cable disconnected).
  • Remove the storage tank (2 screws + washers).
  • Loosen the screw (2) of the oil mist eliminator's mounting bracket.
  • Remove the fixing clamp of the hose (3) and then the hose.
  • Replace the oil mist eliminator.
  • Oil Mist Eliminator for ASM142, ASM182, and ASM340 WET  Helium Leak Detectors, 121494
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Adixen Oil Mist Eliminator for ASM 142, ASM 182, and ASM 340 WET Helium Leak Detectors, 121494
Item#: PN22410 Mfr Part#: 121494 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen Oil Mist Eliminator for ASM142, ASM182, and ASM340 WET Helium Leak Detectors, 121494


The Pfeiffer Adixen 121494 oil mist eliminator is an OEM replacement for Pfeiffer part number 107348. 

121494 is the recommended oil mist eliminator for ASM series leak detectors such as:

  • ASM 142
  • ASM 182
  • ASM 340

 


Replacement of the internal Oil Mist Eliminator

  • 5 mm Allen key supplied in the maintenance kit
  •  Oil mist eliminator: (see 9)Procedure
  • Make sure that the detector is off (circuit breaker on 0, control panel switched offand mains power cable disconnected).
  • Remove the storage tank (2 screws + washers).
  • Loosen the screw (2) of the oil mist eliminator's mounting bracket.
  • Remove the fixing clamp of the hose (3) and then the hose.
  • Replace the oil mist eliminator.

New Pfeiffer Adixen Oil Mist Eliminator for ASM 142, ASM 182, and ASM 340 WET  Helium Leak Detectors, 121494


 

Replacement of the internal Oil Mist Eliminator

 

  • 5 mm Allen key supplied in the maintenance kit
  •  Oil mist eliminator: (see 9)Procedure
  • Make sure that the detector is off (circuit breaker on 0, control panel switched offand mains power cable disconnected).
  • Remove the storage tank (2 screws + washers).
  • Loosen the screw (2) of the oil mist eliminator's mounting bracket.
  • Remove the fixing clamp of the hose (3) and then the hose.
  • Replace the oil mist eliminator.
  • Oil Mist Eliminator for ASM142, ASM182, and ASM340 WET  Helium Leak Detectors, 121494
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.